AC LOSSES IN CROSSBONDED AND BONDED AT BOTH ENDS HIGH VOLTAGE CABLES.

被引:0
|
作者
Kuffel, E.
Poltz, J.
机构
关键词
D O I
暂无
中图分类号
学科分类号
摘要
An integral equation method for calculating eddy-current and circulating-current losses in low-resistance sheaths of the three-core cable in triangular formation has been developed. The theory takes into account the influence between eddy-currents and circulating-currents and can be applied to any system. The losses have been calculated for sheaths bonded at both ends and for cross-bonded or bonded only at one end. In addition the proximity effect between the cores and the sheaths has been considered. The method was then applied to loss estimation in sheaths and metallic cooling pipes surrounding the three-cable system in triangular configuration. Several practical important conclusions have been drawn and good agreement with other published calculated and measured results have been obtained.
引用
收藏
相关论文
共 50 条
  • [31] Diagnostic and acceptance tests of AC long lengths high voltage power cables
    Jaroslaw, Parciak
    Edward, Gulski
    Aleksandra, Rakowska
    Krzysztof, Siodla
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [32] Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables
    Saleh, Mohammad AlShaikh
    Refaat, Shady S.
    Olesz, Marek
    Abu-Rub, Haitham
    2021 96TH IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP 2021) / 16TH IEEE NANOTECHNOLOGY MATERIALS AND DEVICES CONFERENCE (IEEE NMDC 2021), 2021, : 269 - 274
  • [33] Pressurized air cables to reduce transmission losses in medium- and high-voltage grids
    Holaus, Walter
    Tanasic, Zeljko
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2023, 140 (7-8): : 614 - 619
  • [34] Induced Losses in Three-Core SL-Type High-Voltage Cables
    Goddard, Kevin F.
    Pilgrim, James A.
    Chippendale, Richard
    Lewin, Paul L.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) : 1505 - 1513
  • [35] Data Transmission via Insulated Earth Wires of High-Voltage Overhead Cables. Algorithm Programming and Calculation Results.
    Glaeser, Ulrich
    Weidlich, Siegrid
    Hoy, Christian
    Wittig, Franz
    Energietechnik Leipzig, 1980, 30 (08): : 291 - 295
  • [36] The Effects of Seasonal Factors on Life and Reliability of High Voltage AC Cables Subjected to Load Cycles
    Mazzanti, Giovanni
    IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (04) : 2080 - 2088
  • [37] Measurements of partial discharges and power losses in pet films in high voltage ac fields
    Theodosiou, Konstantinos
    Agoris, Dimosthenis P.
    Gialas, Ioannis
    Vitellas, Isidoros
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2007, 58 (05): : 250 - 256
  • [38] Electric Field Distribution and Dielectric Losses in XLPE Insulation and Semiconductor Screens of High-Voltage Cables
    Nadolny, Zbigniew
    ENERGIES, 2022, 15 (13)
  • [39] Water Tree Growth of Wet XLPE Cables Stressed with DC and High Frequency AC Voltage Superimposed
    Mauseth, Frank
    Amundsen, Martin
    Faremo, Hallvard
    CONFERENCE RECORD OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2012, : 266 - 269
  • [40] Opportunities for High-Voltage AC Superconducting Cables as Part of New Long-Distance Transmission Lines
    Kottonau, D.
    Shabagin, E.
    Noe, M.
    Grohmann, S.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)