EXPERIENCES WITH TRACK ETCH DETECTORS FOR RADON MEASUREMENTS.

被引:0
|
作者
Makelainen, Ilona [1 ]
机构
[1] Finnish Cent for Radiation &, Nuclear Safety, Helsinki, Finl, Finnish Cent for Radiation & Nuclear Safety, Helsinki, Finl
来源
Nuclear tracks | 1985年 / 12卷 / 1-6期
关键词
ETCHING - HOUSES - Radioactivity - RADIATION DETECTORS;
D O I
暂无
中图分类号
学科分类号
摘要
Closed Makrofol polycarbonate detectors have been used for radon surveys in dwellings. Three types of plastic detector cups were tested; of these the one painted inside with conductive paint proved to have the smallest standard deviation. Radon measurements with high track densities require a linearity correction.
引用
收藏
页码:717 / 720
相关论文
共 50 条
  • [21] Comparative measurements of soil gas radon concentration using thermoluminescent and track detectors
    Turek, K
    Gelev, M
    Dimov, I
    RADIATION MEASUREMENTS, 2004, 38 (4-6) : 843 - 846
  • [22] Effects of atmospheric parameters on radon measurements using alpha-track detectors
    Zhao, C.
    Zhuo, W.
    Fan, D.
    Yi, Y.
    Chen, B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [23] Some investigations and use of LR-115 track detectors for radon measurements
    Amrani, D
    Belgaid, M
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 639 - 641
  • [24] RADON MEASUREMENTS IN COAL-MINES USING POLYMERIC NUCLEAR TRACK DETECTORS
    TUFAIL, M
    MATIULLAH
    ALI, A
    ORFI, SD
    QURESHI, AA
    HUSSAIN, G
    KHAN, HA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 15 (1-4): : 655 - 658
  • [25] A study of the radiobiological effectiveness with track etch detectors
    Waheed, A
    Manzoor, S
    Moschini, G
    Cherubini, R
    Popa, V
    Giacomelli, G
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 463 - 466
  • [26] TRACK ETCH DETECTORS FOR ALPHA EXPOSURE ESTIMATION
    LOVETT, DB
    HEALTH PHYSICS, 1969, 16 (05): : 623 - +
  • [27] RECENT ADVANCES IN TRACK ETCH RADON DETECTION SYSTEMS
    ALTER, HW
    GINGRICH, JE
    FISHER, JC
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1980, 34 (JUN): : 141 - 141
  • [28] Effect of track etch rate on geometric track characteristics for polymeric track detectors
    Abdel-Naby, AA
    El-Akkad, FA
    RADIATION MEASUREMENTS, 2001, 33 (01) : 145 - 150
  • [29] ASSESSEMENT OF INDOOR RADON, THORON AND THEIR PROGENY IN DWELLINGS OF BAREILLY CITY OF NORTHERN INDIA USING TRACK ETCH DETECTORS
    Verma, Deepak
    Khan, M. Shakir
    ROMANIAN JOURNAL OF PHYSICS, 2014, 59 (1-2): : 172 - 182
  • [30] RESPONSE OF TRACK-ETCH DOSIMETERS TO ENVIRONMENTAL RADON
    SUTEJ, T
    ILIC, R
    NAJZER, M
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 15 (1-4): : 547 - 550