EXPERIENCES WITH TRACK ETCH DETECTORS FOR RADON MEASUREMENTS.

被引:0
|
作者
Makelainen, Ilona [1 ]
机构
[1] Finnish Cent for Radiation &, Nuclear Safety, Helsinki, Finl, Finnish Cent for Radiation & Nuclear Safety, Helsinki, Finl
来源
Nuclear tracks | 1985年 / 12卷 / 1-6期
关键词
ETCHING - HOUSES - Radioactivity - RADIATION DETECTORS;
D O I
暂无
中图分类号
学科分类号
摘要
Closed Makrofol polycarbonate detectors have been used for radon surveys in dwellings. Three types of plastic detector cups were tested; of these the one painted inside with conductive paint proved to have the smallest standard deviation. Radon measurements with high track densities require a linearity correction.
引用
收藏
页码:717 / 720
相关论文
共 50 条
  • [1] EXPERIENCES WITH TRACK ETCH DETECTORS FOR RADON MEASUREMENTS
    MAKELAINEN, I
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 717 - 720
  • [2] TRACK ETCH DETECTORS FOR RADON AND RADON-DAUGHTER MEASUREMENTS
    FLEISCHER, RL
    GINGRICH, JE
    HEALTH PHYSICS, 1979, 37 (06): : 825 - 825
  • [3] INDOOR RADON MEASUREMENTS WITH TRACK-ETCH DETECTORS
    OSWALD, RA
    ALTER, HW
    GINGRICH, JE
    HEALTH PHYSICS, 1982, 43 (01): : 122 - 122
  • [4] THE APPLICATION OF TRACK ETCH DETECTORS TO ENVIRONMENTAL RADON MONITORING
    ALTER, HW
    GINGRICH, JE
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1981, 39 : 111 - 111
  • [5] RECENT DEVELOPMENTS IN PASSIVE TRACK ETCH RADON DETECTORS
    OSWALD, RA
    ALTER, HW
    GINGRICH, JE
    HEALTH PHYSICS, 1983, 45 (01): : 197 - 197
  • [6] ROLE OF NUCLEAR TRACK FILTERS IN RADON MEASUREMENTS.
    Sial, M.A.
    Jamil, K.
    Sheikh, S.A.
    Khan, H.A.
    Molzahn, D.
    Vater, P.
    Brandt, R.
    Nuclear tracks, 1985, 12 (1-6): : 705 - 708
  • [7] INTERLABORATORY CALIBRATION OF TRACK-ETCH DETECTORS FOR THE MEASUREMENT OF RADON AND RADON DAUGHTER LEVELS
    JOJO, PJ
    KHAN, AJ
    TYAGI, RK
    RAMACHANDRAN, TV
    RAMU, MCS
    PRASAD, R
    RADIATION MEASUREMENTS, 1994, 23 (04) : 715 - 724
  • [8] Superheated emulsions and track etch detectors for photoneutron measurements
    Di Fulvio, A.
    Domingo, C.
    De San Pedro, M.
    D'Agostino, E.
    Caresana, M.
    Tana, L.
    d'Errico, F.
    RADIATION MEASUREMENTS, 2013, 57 : 19 - 28
  • [9] USE OF CELLULOSE NITRATE AS RADON DAUGHTERS DETECTORS FOR INDOOR MEASUREMENTS.
    Rannou, A.
    Jeanmaire, L.
    Tymen, G.
    Mouden, A.
    Naour, E.
    Parmentier, N.
    Renouard, H.
    Nuclear tracks, 1985, 12 (1-6): : 747 - 750
  • [10] RESULTS OF INDOOR RADON MEASUREMENTS USING THE TRACK ETCH METHOD
    ALTER, HW
    OSWALD, RA