Removal of bentonite causing turbidity by electro-coagulation

被引:0
|
作者
Abuzaid, Nabil S. [1 ]
Bukhari, Alaadin A. [2 ]
Al-Hamouz, Zakariya M. [3 ]
机构
[1] Research Institute, King Fahd Univ. Petrol. and Minerals, Dhahran 31261, Saudi Arabia
[2] Civil Engineering Department, King Fahd Univ. Petrol. and Minerals, Dhahran 31261, Saudi Arabia
[3] Electrical Engineering Department, King Fahd Univ. Petrol. and Minerals, Dhahran 31261, Saudi Arabia
关键词
Bentonite - Coagulation - Electrochemical electrodes - Electrolytes - Sodium chloride - Stainless steel - Turbidity;
D O I
暂无
中图分类号
学科分类号
摘要
The efficiency of electro-coagulation as a turbidity removal process has been investigated using bentonite as a turbidity source. The influence of certain operational parameters such as current input, contact time, electrolyte concentration, and initial turbidity on the coagulation efficiency were studied. The process was found to achieve excellent turbidity removals. The lowest residual turbidities were 0.5 and 0.75 NTU for the samples with initial turbidities of 112 and 52 NTU, respectively. This was obtained at a current of 0.5 A, a contact time of 5 minutes, and a calculated dissolved iron concentration of 10.8 mg/l. At a constant current of 0.5 A, a reduction in the contact time from 5 to 2 minutes in the case of turbidity level 1 (52 NTU) and from 5 to 1 minute in the case of turbidity level 2 (112 NTU) resulted in better turbidity removals. The optimal operational parameters for turbidity level 1 are a current of 0.5 A, a contact time of 2 minutes and an NaCl concentration of 2 g/l resulting in a calculated amount of iron generated of 4.3 mg/l. However, for the case of turbidity level 2, the optimal values are a current of 0.5 A, a contact time of 1 minute and an NaCl concentration of 5 g/l with a calculated iron amount generated of 2.2 mg/l.
引用
收藏
页码:1341 / 1358
相关论文
共 50 条
  • [21] Removal of ciprofloxacin from aqueous solution by a continuous flow electro-coagulation process
    Parsa, Jalal Basiri
    Panah, Taher Mehdi
    Chianeh, Farideh Nabizadeh
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2016, 33 (03) : 893 - 901
  • [22] Hydrodynamic effects on the performance of electro-coagulation/electro-flotation for the removal of dyes from textile wastewater
    Szpyrkowicz, L
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (20) : 7844 - 7853
  • [23] Electro-coagulation of the prostate - Immediate and late results
    Williams, H
    BRITISH MEDICAL JOURNAL, 1934, 1934 : 549 - 552
  • [24] Phosphorous removal from wastewater effluent using electro-coagulation by aluminum and iron plates
    Gharibi, Hamed
    Mahvi, Amir Hossein
    Chehrazi, Mohammad
    Sheikhi, Razih
    Hosseini, Sara Sadat
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2010, 2 (03): : 165 - 177
  • [25] Arsenite removal from water by electro-coagulation on zinc–zinc and copper–copper electrodes
    I. Ali
    Mohd. Asim
    T. A. Khan
    International Journal of Environmental Science and Technology, 2013, 10 : 377 - 384
  • [26] Experimental design of wastewater treatment with electro-coagulation
    Camcioglu, Sule
    Pekel, Lutfiye Canan
    Polat, Kamran
    Hapoglu, Hale
    MANAGEMENT OF ENVIRONMENTAL QUALITY, 2014, 25 (01) : 86 - 95
  • [27] ELECTRO-COAGULATION FOR REMOVAL AND RECOVERY OF POLLUTANTS FROM MEAT PACKING HOUSE LIQUID EFFLUENT
    CLEMENS, OA
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1980, 57 (02) : A156 - A156
  • [28] ELECTRO-RESECTION AND ELECTRO-COAGULATION IN THERAPY OF VULVA CARCINOMA
    WEGHAUPT, K
    FORTSCHRITTE DER MEDIZIN, 1978, 96 (33) : 1629 - 1634
  • [29] Cost effectiveness ratio in fluoride removal from water using electrochemical, coagulation, and combined electro-coagulation processes
    Mahvi, Amir Hossein
    Salem, Atieh
    Parmoozeh, Zahra
    Rabbani, Davarkhah
    DESALINATION AND WATER TREATMENT, 2020, 207 : 180 - 184
  • [30] Electro-coagulation coupled electro-flotation process: Feasible choice in doxycycline removal from pharmaceutical effluents
    Zaidi, S.
    Chaabane, T.
    Sivasankar, V.
    Darchen, A.
    Maachi, R.
    Msagati, T. A. M.
    ARABIAN JOURNAL OF CHEMISTRY, 2019, 12 (08) : 2798 - 2809