WATER CALORIMETER FOR MEASURING PHOTON-RADIATION ABSORBED DOSE RATES.

被引:0
|
作者
Berlyand, V.A.
Bregadze, Yu.I.
机构
关键词
DOSIMETRY; -; Standards;
D O I
暂无
中图分类号
学科分类号
摘要
Recently, increasing attention has been given to methods of determining ionizing-radiation absorbed doses, in particular in dosimetry for radiation safety, in radiotherapy, and in monitoring effects on materials in the engineering use of radiation. The transfer from exposure dose to absorbed dose for photon radiation has been caused by difficulties in using the SI unit for exposure dose, Cu/kg. Two problems are discussed in relation to abandoning exposure dose; the first is choosing the quantities that should be measured by working instruments, while the second is that of standards and the calibration of instruments by means of them. The use of a water calorimeter is described. Reproducibility and measurement error are also discussed.
引用
收藏
页码:1100 / 1103
相关论文
共 50 条
  • [21] Experimental verification of calculated radiation-induced heat conduction effects in the water absorbed dose calorimeter
    Krauss, A
    THERMOCHIMICA ACTA, 2002, 382 (1-2) : 99 - 107
  • [22] Heat transport by material-dependent heating during absorption of radiation in the water absorbed dose calorimeter
    Krauss, A
    Roos, M
    THERMOCHIMICA ACTA, 1999, 337 (1-2) : 45 - 49
  • [23] Challenges in measuring absorbed dose with a simple open-to-atmosphere graphite calorimeter
    Bourgouin, Alexandra
    Cojocaru, Claudiu
    McEwen, Malcolm
    MEDICAL PHYSICS, 2017, 44 (08) : 4389 - 4390
  • [24] Commissioning of a water calorimeter as a primary standard for absorbed dose to water in magnetic fields
    de Prez, Leon
    de Pooter, Jacco
    Jansen, Bartel
    Woodings, Simon
    Wolthaus, Jochem
    van Asselen, Bram
    van Soest, Theo
    Kok, Jan
    Raaymakers, Bas
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (03):
  • [25] Development of a Thimble Calorimeter for Absorbed Dose to Water Characterized in MV Photons
    Chen-Mayer, H.
    Bateman, F.
    Tosh, R.
    Bergstrom, P.
    MEDICAL PHYSICS, 2016, 43 (06) : 3664 - 3664
  • [26] ABSORBED DOSE DETERMINATION WITH A WATER CALORIMETER IN COMPARISON WITH AN IONIZATION-CHAMBER
    KUBO, H
    PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (12): : 1391 - 1399
  • [27] INVESTIGATION OF A WATER CALORIMETER IN ESTABLISHING AN ABSORBED DOSE STANDARD FOR ION CHAMBERS
    MARLES, AM
    ALMOND, PR
    MEDICAL PHYSICS, 1981, 8 (04) : 572 - 573
  • [28] Simulating absorbed dose: Finite element modeling of a stirred water calorimeter
    Chen-Mayer, H.
    Tosh, R.
    MEDICAL PHYSICS, 2006, 33 (06) : 2136 - 2136
  • [29] GRAPHITE CALORIMETER FOR ABSORBED DOSE STANDARDIZATION OF GAMMA-RADIATION PROCESSING PLANTS
    YOUSSEF, SK
    RAO, ISS
    VOHRA, KG
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1981, 32 (12): : 869 - 875
  • [30] A robust method for determining the absorbed dose to water in a phantom for low-energy photon radiation
    Schneider, T.