Development of the double-rod-type jumper horns in strain assemblies with pipe jumpers for 500-kV transmission lines

被引:0
|
作者
Shibuya, Masatoyo [1 ]
Amakawa, Tadashi [1 ]
Sano, Kiyoshi [1 ]
Kimura, Sakae [1 ]
机构
[1] Central Research Inst of Electric, Power Industry
关键词
500 kV transmission lines - Double rod type jumper horns - Pipe jumpers - Strain assemblies;
D O I
暂无
中图分类号
学科分类号
摘要
This paper proposes double-rod-type jumper horns in strain assemblies with pipe jumpers for 500-kV transmission lines, the structure of which is very simple. It can be estimated that no corona discharge appears on the horns under the line voltage of 525 kV. The arc behavior on the double-rod-type jumper horns is similar to that on the single-rod-type horns. The arc can be held stably for 60 ms against strong wind (10 m/s). The stable duration increases more than 300 ms under windless condition, therefore the horns have been adopted for practical use.
引用
收藏
页码:52 / 60
相关论文
共 8 条
  • [1] Electromagnetic Environmental Impact of 500-kV Double -Circuit Transmission Lines
    Qi Jianzhao
    Electricity, 2011, 22 (01) : 24 - 28
  • [2] Development of 500-kV XLPE cables and accessories for long-distance underground transmission lines .4. Electrical properties of 500-kV extrusion molded joints
    Takeda, N
    Izumi, S
    Asari, K
    Nakatani, A
    Noda, H
    Yamaguchi, M
    Tan, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (02) : 635 - 643
  • [3] Study on Electric Field Distribution of Cage-type Rigid Jumper for 500 kV AC Transmission Lines
    Cai, Haohui
    Peng, Zongren
    Yang, Xi
    2012 IEEE 10TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM), 2012,
  • [4] Development of 500-kV XLPE cables and accessories for long-distance underground transmission lines .5. Long-term performance for 500-kV XLPE cables and joints
    Kaminaga, K
    Ichihara, M
    Jinno, M
    Fujii, O
    Fukunaga, S
    Kobayashi, M
    Watanabe, K
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (03) : 1185 - 1194
  • [5] Reliability Evaluation and Weak Component Identification of ±500-kV HVDC Transmission Systems With Double-Circuit Lines on the Same Tower
    Hu, Bo
    Xie, Kaigui
    Tai, Heng-Ming
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (04) : 1716 - 1726
  • [6] DEVELOPMENT OF 500-KV XLPE CABLES AND ACCESSORIES FOR LONG-DISTANCE UNDERGROUND TRANSMISSION-LINES .2. JOINTING TECHNIQUES
    KUBOTA, T
    TAKAHASHI, Y
    HASEGAWA, T
    NODA, H
    YAMAGUCHI, M
    TAN, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (04) : 1750 - 1759
  • [7] Development of new technology to access the energized phase by walking along the strain string on 500 kV transmission lines and substations
    Assad, LAX
    Braga, AE
    de Andrade, VHG
    ESMO '98 PROCEEDINGS: ESMO '98 - 1998 IEEE 8TH INTERNATIONAL CONFERENCE ON TRANSMISSION & DISTRIBUTION CONSTRUCTION, OPERATION & LIVE-LINE MAINTENANCE PROCEEDINGS, 1996, : 135 - 140
  • [8] Analysis of lightning-induced current and voltages on 500 kV EHV double circuit transmission lines of type DL3° andd DT 20° in lightning protection system
    Jaipradidtham, C
    TENCON 2004 - 2004 IEEE REGION 10 CONFERENCE, VOLS A-D, PROCEEDINGS: ANALOG AND DIGITAL TECHNIQUES IN ELECTRICAL ENGINEERING, 2004, : C385 - C388