Study on Electric Field Distribution of Cage-type Rigid Jumper for 500 kV AC Transmission Lines

被引:0
|
作者
Cai, Haohui [1 ]
Peng, Zongren [1 ]
Yang, Xi [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
关键词
cage-type rigid jumper; electric field; finite element method; corona; extra-high voltage;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cage-type rigid jumper is an essential connecting component on extra-high voltage (EHV) transmission lines, but with a more serious distortion of surface electric field than straight bundled conductor due to its complex structure and bending. In order to optimize the structure for a jumper with less corona loss, distribution of electric field on the surface of such a jumper is modeled and studied. In this paper, three-dimensional finite element method is applied to simulate the electric field distribution on the surface of quad bundle cage-type rigid jumper on 500kV AC transmission lines; the external diameter of and space between sub-jumpers are varied to observe the changes in electric field as a function of jumper structural dimensions. Three conclusions are obtained: the maximum intensity of electric field increases with the whole curvature of the jumper; the maximum intensity of electric field decreased with the external diameter of sub-jumpers; the intensity as a function of sub-jumper spacing appears to be a U profile. These conclusions could provide reference to the design of extra-high voltage and ultra-high voltage transmission lines.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Study on Electric Field Distribution of Cage-type Rigid Jumper for 1000kV AC Ultra High Voltage Transmission Lines
    Li, Jing
    Peng, Zongren
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 77 - 80
  • [2] Study on Electric Field Distribution Characteristics of Live-Working and Protection for Crossing Project of 1000kV-Over-500kV AC Transmission Lines
    Huo F.
    Lu W.
    Huang D.
    Nan J.
    Qiu Z.
    Huang C.
    Dianwang Jishu/Power System Technology, 2019, 43 (01): : 349 - 355
  • [3] Electric Field Distribution Calculation and Analysis on the Surface of Jumper on Double Circuit Transposition Tower in UHV AC Transmission Lines
    Yang, Xi
    Peng, Zongren
    Li, Naiyi
    Cai, Haohui
    Zhang, Shiling
    Liao, Jintao
    PROCEEDINGS OF THE 2013 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS (ICSD 2013), VOLS 1 AND 2, 2013, : 202 - 205
  • [4] Electric Field Calculation and Grading Ring Optimization of Composite Insulator for 500kV AC Transmission Lines
    Li, Jing
    Peng, Zongren
    Feng, Yong
    Fu, Xiaoyong
    Xie, Tianxi
    PROCEEDINGS OF THE 2010 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS (ICSD 2010), 2010,
  • [5] Study on surface electric field distribution of jumper in 220 kV tension tower
    Zhu, Lijuan
    Yang, Xi
    Qin, Shaorui
    Zhan, Xuhai
    Yang, Li
    Wu, Yezhi
    2021 96TH IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP 2021) / 16TH IEEE NANOTECHNOLOGY MATERIALS AND DEVICES CONFERENCE (IEEE NMDC 2021), 2021, : 474 - 477
  • [6] Study on Distribution Model of Electric Field for 220kV Transmission Lines and Implement
    Zhang, Guangzhou
    Li, Mu
    Zhang, Gongda
    Zhang, Hu
    Fang, Shubo
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 2315 - 2319
  • [7] Simulation of effect on 500 kV AC transmission line electric field of patrol helicopters
    Wang, Liming
    Yu, Deming
    Chen, Fangdong
    Wan, Shuwei
    Bian, Xingming
    Chen, Lan
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (01): : 201 - 209
  • [8] Servicing of the 500 kV Transmission Lines with the use of Calculate Cards of Intensity Distribution in Electric Field of Industrial Frequency
    Tavarov, S. Sh
    Sidorov, A., I
    Medvedeva, Yu., V
    2016 2ND INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2016,
  • [9] Corona discharge effect on frequency electric field distribution for AC transmission lines
    Zhou, Yusheng
    An, Zhengzhou
    Liu, Rangjiao
    Peng, Pai
    Gao, Yunlong
    Xiong, Jie
    MODERN COMPUTER SCIENCE AND APPLICATIONS (MCSA 2016), 2016, : 169 - 174
  • [10] Voltage and Electric Field Distribution along Porcelain Long Rod Insulator String in AC 500kV Transmission Line
    Zhang, Baiqing
    Cui, Yandong
    Zhang, Wei
    Liu, Siyi
    Zheng, Qiuwei
    Yang, Shuai
    Gao, Song
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,