CONTROL SYSTEM FOR FORT HOOD SOLAR TOTAL ENERGY SYSTEM.

被引:0
|
作者
Luffey, F.C.
Black, D.L.
机构
关键词
Computers; Analog - CONTROL SYSTEMS; DIGITAL - Computer Interfaces;
D O I
暂无
中图分类号
学科分类号
摘要
The Fort Hood Solar Total Energy System Large Scale Experiment (STES-LSE) was designed to supply 70 million Btu/day to the 87 thousand barracks complex at Fort Hood, Texas. Solar energy is collected via a mirrored parabolic trough and delivered to thermal storage tanks from which the balance of the plant operates up to 24 hours per day. The control of the components of the Fort Hood STES-LSE is via a ″software driven″ digital computer based control system interfaced with analog control elements. A master computer located in the central control room communicates asynchronously to field distributed process units (DPU) via parallel linked transmission lines.