FIELD SURGE TESTS ON KANSAI ELECTRIC POWER COMPANY'S 500 KV TRANSMISSION SYSTEM.

被引:0
|
作者
Matsumura, Susumu
Kinoshita, Hitoshi
Ozaki, Yuzo
机构
来源
| 1976年
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Results are given of an investigation of the lightning impulse characteristics, insulation coordination of the electric stations, and switching surge created in circuits of a 500 kv transmission line system.
引用
收藏
相关论文
共 50 条
  • [21] The bulk power transmission system of tokyo electric power company: History and future prospects
    Kitajima, Takashi
    IEEJ Transactions on Fundamentals and Materials, 2008, 128 (03) : 153 - 157
  • [22] Radio interference and electric field of 500 kV four circuits on one tower transmission line
    Wan, Bao-Quan
    Lu, Yao
    Wu, Xiong
    Wang, Zuo-Min
    Jia, Zhen-Hong
    Gaodianya Jishu/High Voltage Engineering, 2007, 33 (03): : 113 - 116
  • [23] Management of the geomagnetically induced current risks on the national grid company's electric power transmission system
    Erinmez, IA
    Kappenman, JG
    Radasky, WA
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2002, 64 (5-6) : 743 - 756
  • [24] Research on the Motion System of the Inspection Robot for 500kV Power Transmission Lines
    Fang, L. J.
    Wang, H. G.
    2010 1ST INTERNATIONAL CONFERENCE ON APPLIED ROBOTICS FOR THE POWER INDUSTRY, 2010,
  • [25] Total monitoring system for the reihoku thermal power transmission line of the Kyushu Electric Power Company
    Matsubara, Ichiro
    Nakano, Tsuneo
    Hara, Takushi
    Sakurai, Keishi
    Wada, Osamu
    Yasumori, Toshihisa
    Kondou, Takashi
    Nishioka, Masaru
    Sumitomo Electric Technical Review, 1996, (42):
  • [26] Study of increasing 500kV transmission line capacity of East China electric power grid
    Zhang, QP
    Qian, ZY
    Proceedings of the World Engineers' Convention 2004, Vol F-B, Power and Energy, 2004, : 376 - 380
  • [27] Finite Element Analysis of Magnetic Field Distribution for 500-kV Power Transmission Systems
    Pao-la-or, P.
    Isaramongkolrak, A.
    Kulworawanichpong, T.
    ENGINEERING LETTERS, 2010, 18 (01)
  • [28] INSTALLATION OF 275kV OF CABLE ON THE SLOPE IN KITA TOYONAKA TRANSMISSION LINE OF THE KANSAI ELECTRIC POWER CO. , INC.
    Nagahama, I.
    Fujiyoshi, H.
    Simada, A.
    Suzuki, T.
    Tsuji, H.
    Watanabe, S.
    Minaguchi, D.
    Wakabayasi, H.
    Dainichi-Nippon Cables Review, 58 (37-48):
  • [29] RIGHT-OF-WAY AND CONDUCTOR SELECTION FOR ALLEGHENY POWER SYSTEM 500-KV TRANSMISSION SYSTEM
    GUYKER, WC
    ONEIL, JE
    HILEMAN, AR
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1966, PA85 (06): : 624 - &
  • [30] Research on line ZnO surge arrester without supporting series gap for 500kV AC power transmission line
    Hui, YJ
    Cai, DK
    Hu, Z
    Xiao, Y
    Qiu, DF
    PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2004, : 419 - 422