Design of a magnetic bearing-supported prototype centrifugal artificial heart pump

被引:0
|
作者
University of Virginia, Mechanical,, Aerospace, and Nuclear Engineering, Department, Charlottesville, Virginia 22901 [1 ]
机构
来源
Tribol Trans | / 3卷 / 663-669期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Design of a magnetic bearing-supported prototype centrifugal artificial heart Pump
    Allaire, PE
    Maslen, EH
    Kim, HC
    Bearnson, GB
    Olsen, DB
    TRIBOLOGY TRANSACTIONS, 1996, 39 (03): : 663 - 669
  • [2] A pivot bearing-supported centrifugal pump for a long-term assist heart
    Nakazawa, T
    Ohara, Y
    Benkowski, R
    Makinouchi, K
    Takami, Y
    Ohtsubo, S
    Kawahito, K
    Tasai, K
    Glueck, J
    Noon, GP
    Sueoka, A
    Schmallegger, H
    Schima, H
    Wolner, E
    Nose, Y
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (04): : 222 - 228
  • [3] Quantitative approach to control spinning stability of the impeller in the pivot bearing-supported centrifugal pump
    Department of Surgery, Baylor College of Medicine, Houston, TX, United States
    不详
    Artif. Organs, 12 (1292-1296):
  • [4] Quantitative approach to control spinning stability of the impeller in the pivot bearing-supported centrifugal pump
    Takami, Y
    Makinouchi, K
    Otsuka, G
    Nose, Y
    ARTIFICIAL ORGANS, 1997, 21 (12) : 1292 - 1296
  • [5] Safety margin of magnetic coupling distance in decoupling of a pivot bearing-supported gyro centrifugal pump (C1E3)
    Takami, Y
    Nakazawa, T
    Makinouchi, K
    Glueck, J
    Benkowski, R
    Nose, Y
    ARTIFICIAL ORGANS, 1996, 20 (07) : 817 - 819
  • [6] Pump power loss and heat generation in a pivot bearing-supported gyro centrifugal pump (C1E3)
    Takami, Y
    Nakazawa, T
    Makinouchi, K
    Glueck, J
    Ohara, Y
    Benkowski, RJ
    Nose, Y
    ARTIFICIAL ORGANS, 1996, 20 (07) : 794 - 797
  • [7] Design of a Centrifugal Blood Pump: Heart Turcica Centrifugal
    Demir, Onur
    Biyikli, Emre
    Lazoglu, Ismail
    Kucukaksu, Suha
    ARTIFICIAL ORGANS, 2011, 35 (07) : 720 - U138
  • [8] EVALUATION OF THE MAGLEV MOTOR AND DESIGN OF THE CENTRIFUGAL BLOOD PUMP FOR PEDIATRIC ARTIFICIAL HEART
    Osa, M.
    Masuzawa, T.
    Tatsumi, E.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (08): : 609 - 609
  • [9] Eccentric inlet port of the pivot bearing supported Gyro centrifugal pump
    Takami, Y
    Andrade, A
    Nakazawa, T
    Makinouchi, K
    Glueck, J
    Benkowski, R
    Nose, Y
    ARTIFICIAL ORGANS, 1997, 21 (04) : 312 - 317
  • [10] Development of a pivot bearing supported sealless centrifugal pump for ventricular assist
    Nakazawa, T
    Makinouchi, K
    Ohara, Y
    Ohtsubo, S
    Kawahito, K
    Tasai, K
    Shimono, T
    Benkowski, R
    Damm, G
    Takami, Y
    Glueck, J
    Noon, GP
    Nose, Y
    ARTIFICIAL ORGANS, 1996, 20 (06) : 485 - 490