VARIABLE AIR VOLUME SYSTEMS.

被引:0
|
作者
Patterson, Neil R.
机构
来源
关键词
FANS; -; VENTILATION;
D O I
暂无
中图分类号
学科分类号
摘要
High-velocity variable air volume (VAV) systems control space conditions by altering air quantity instead of temperature. Constant-volume systems, such as terminal reheat, multizone, and double duct, maintain a constant air flow and control space temperature by using reheat coils or mixing hot and cold air streams. VAV installations are more difficult to design and control than constant volume systems because widely fluctuating air flows and static pressures are encountered; however, VAV is usually more energy-efficient. The fan system that moves the air and overcomes resistance is the key ingredient in a VAV installation. This first article in a two-part series discusses types, modulation, and selection of VAV system fans.
引用
收藏
页码:87 / 90
相关论文
共 50 条
  • [41] Life-cycle cost analysis for constant-air-volume and variable-air-volume air-conditioning systems
    Aktacir, MA
    Büyükalaca, O
    Yilmaz, T
    APPLIED ENERGY, 2006, 83 (06) : 606 - 627
  • [42] On the geometrical representation of the motion of variable systems.
    Cardinaal, J
    PROCEEDINGS OF THE KONINKLIJKE AKADEMIE VAN WETENSCHAPPEN TE AMSTERDAM, 1903, 5 : A386 - A391
  • [43] VARIABLE FLOW CHILLED WATER SYSTEMS.
    Kirshenbaum, Marvin
    1600, (29):
  • [44] Optimized supply-air temperature (SAT) in variable-air-volume (VAV) systems
    Ke, YP
    Mumma, SA
    ENERGY, 1997, 22 (06) : 601 - 614
  • [45] Comparative study of the cooling energy performance of variable refrigerant flow systems and variable air volume systems in office buildings
    Yu, Xinqiao
    Yan, Da
    Sun, Kaiyu
    Hong, Tianzhen
    Zhu, Dandan
    APPLIED ENERGY, 2016, 183 : 725 - 736
  • [46] Evaluation program for the energy-saving of variable-air-volume systems
    Yao, Ye
    Lian, Zhiwei
    Liu, Weiwei
    Hou, Zhijian
    Wu, Ming
    ENERGY AND BUILDINGS, 2007, 39 (05) : 558 - 568
  • [47] FAN SELECTION AND CONTROL IN HIGH-VELOCITY VARIABLE AIR VOLUME SYSTEMS
    PATERSON, N
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1976, 18 (12): : 38 - 38
  • [48] STUDY ON ENERGY SAVINGS WITH VARIABLE AIR VOLUME SYSTEMS BY SIMULATION AND FIELD MEASUREMENT
    INOUE, U
    MATSUMOTO, T
    ENERGY AND BUILDINGS, 1979, 2 (01) : 27 - 36
  • [49] VARIABLE AIR VOLUME DESIGN.
    Langbein Jr., Charles E.
    1978, 75 (04): : 30 - 36
  • [50] ROOM AIR DISTRIBUTION WITH A VARIABLE AIR VOLUME SYSTEM
    STRAUB, HE
    ASHRAE JOURNAL, 1969, 11 (06): : 69 - &