MODULAR NaI(T<L%) DETECTOR FOR INTERMEDIATE ENERGY PHOTONS.

被引:0
|
作者
Bay, A. [1 ]
Joseph, C. [1 ]
Loude, J.F. [1 ]
Perroud, J.P. [1 ]
Ruegger, D. [1 ]
Schori, O. [1 ]
Steiner, D. [1 ]
Tran, M.T. [1 ]
机构
[1] Univ de Lausanne, Lausanne, Switz, Univ de Lausanne, Lausanne, Switz
来源
关键词
NEUTRONS; -; Detectors; PHOTONS; Measurements; Spectrometers;
D O I
暂无
中图分类号
学科分类号
摘要
We describe the properties of a detector array made up of 64 NaI(Tl) 406 multiplied by 63 multiplied by 63 mm**3 modules, used as an intermediate energy photon spectrometer. We obtain an energy resolution of 6% FWHM at 129 Mev, a time resolution of 1 ns FWHM and a resolution of 48 mm FWHM for the location of the impact point on the front face of the detector. The modularity allows to some extent a discrimination between photons and neutrons. We also present the response of the detector to 69 Mev neutrons.
引用
收藏
页码:497 / 506
相关论文
共 50 条
  • [31] A GREY NEUTRON DETECTOR FOR INTERMEDIATE ENERGY REGION
    PONITZ, WP
    NUCLEAR INSTRUMENTS & METHODS, 1968, 58 (01): : 39 - &
  • [32] ON THE ABSORPTION OF INTERMEDIATE-ENERGY PHOTONS BY LIGHT-NUCLEI
    DEALMEIDA, ES
    DINAPOLI, V
    LETTERE AL NUOVO CIMENTO, 1981, 31 (09): : 311 - 316
  • [33] HODOSCOPE-SPECTROMETER FOR INTERMEDIATE AND HIGH-ENERGY PHOTONS
    HEUSCH, CA
    KLINE, RV
    YELLIN, SJ
    NUCLEAR INSTRUMENTS & METHODS, 1974, 120 (02): : 237 - 243
  • [34] Intrinsic energy resolution of NaI(T1)
    Moszynski, M
    Zalipska, J
    Balcerzyk, M
    Kapusta, M
    Mengesha, W
    Valentine, JD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3): : 259 - 269
  • [35] Pixellated NaI (T1) detector for light yield nonproportionality investigation
    Mengesha, W.
    Bowden, N. S.
    Allen, M.
    Lund, J.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1830 - 1835
  • [36] CALCULATION OF RESPONSE OF NAI(T1) DETECTOR TO GAMMA-RADIATION
    BILBAO, J
    CASANOVA, J
    DEMIGUEL, A
    ANALES DE FISICA, 1973, 69 (7-9): : 279 - 286
  • [37] Energy calibration of the NaI(Tl) calorimeter of the SND detector using cosmic muons
    Achasov, MN
    Bukin, AD
    Bukin, DA
    Druzhinin, VP
    Golubev, VB
    Ivanchenko, VN
    Koshuba, SV
    Serednyakov, SI
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 401 (2-3): : 179 - 186
  • [38] Nonproportional scintillation response of NaI:Tl to low energy x-ray photons and electrons
    Khodyuk, I. V.
    Rodnyi, P. A.
    Dorenbos, P.
    JOURNAL OF APPLIED PHYSICS, 2010, 107 (11)
  • [39] A THIN DETECTOR WITH IONIZATION TUBES FOR HIGH-ENERGY ELECTRONS AND PHOTONS
    AMATUNI, TA
    DENISOV, SP
    KRASNOKUTSKY, RN
    LEBEDENKO, VN
    SHUVALOV, RS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 203 (1-3): : 179 - 182
  • [40] HIGH-ENERGY PHOTONS AND PIONS IN INTERMEDIATE ENERGY HEAVY-ION REACTIONS
    BAUER, W
    NUCLEAR EQUATION OF STATE, PART A: DISCOVERY OF NUCLEAR SHOCK WAVES AND THE EOS, 1989, 216 : 331 - 340