Electric preheating. A new method for laying pre-insulated district heating pipes

被引:0
|
作者
Anon
机构
来源
ABB Review | 1990年 / 01期
关键词
Diesel Electric Power Plants - Electric Heating - Applications - Pipe - Insulation - Pipelines - Laying;
D O I
暂无
中图分类号
学科分类号
摘要
i.c.moller a/s of Fredericia, Denmark, is one of the world's leading manufacturers of pre-insulated pipe systems. The company, a member of the ABB Group, has refined district heating pipeline design to a degree where heat losses can be neglected over distances of 100 km and more. Pipe installation is also undergoing continuing improvement at i.c.moller, which has developed a method for electric preheating that makes it easier to prestress friction-locked pipe systems. This method has also proved successful for large-diameter pipes.
引用
收藏
页码:33 / 38
相关论文
共 50 条
  • [21] A New Type of Pre-insulated Bonded Pipe
    Wang Fei
    Yan Guan-long
    Ming Yan
    Wang Guo-wei
    ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 1, PROCEEDINGS, 2009, : 7 - 10
  • [22] Optimum Insulation Thickness, Energy Saving and Fuel Emission Calculation of Aboveground and Underground Pre-Insulated Pipes in Central Heating Systems
    Kon, Okan
    Ilhan, Utku
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2022, 25 (01): : 189 - 203
  • [23] Analysis of thermal insulation of pre-insulated triple pipes-preliminary numerical tests
    Teleszewski T.J.
    Krawczyk D.A.
    Rodero A.
    Renewable Energy and Power Quality Journal, 2020, 18 : 522 - 525
  • [24] Pre-insulated pipe damage statistics 2001 - Quality must be integral to laying, not added later
    Von Brunn, V.H.
    Euroheat and Power/Fernwarme International, 2001, 30 (11): : 30 - 32
  • [25] Reduction of Heat Losses Using Quadruple Heating Pre-Insulated Networks: A Case Study
    Teleszewski, Tomasz Janusz
    Krawczyk, Dorota Anna
    Rodero, Antonio
    ENERGIES, 2019, 12 (24)
  • [26] Heat and mass transfer in polyurethane insulated district cooling and heating pipes
    Eriksson, Daniel
    Sunden, Bengt
    Journal of Thermal Envelope and Building Science, 1998, 22 : 49 - 71
  • [27] The polyethylene casing as diffusion barrier for polyurethane insulated district heating pipes
    Olsson, M
    Jarfelt, U
    Fröling, M
    Ramnäs, O
    CELLULAR POLYMERS, 2001, 20 (01) : 37 - 47
  • [28] Long-term thermal performance of polyurethane-insulated district heating pipes
    Olsson, M.E.
    Doktorsavhandlingar vid Chalmers Tekniska Hogskola, 2001, (1729):
  • [29] Pipeopsy: A Novel Method for Status Assessment of District Heating Pipes in Operation
    Jakubowicz, Ignacy
    Vega, Alberto
    Sallstrom, Jan Henrik
    Yarahmadi, Nazdaneh
    JOURNAL OF PIPELINE SYSTEMS ENGINEERING AND PRACTICE, 2025, 16 (01)
  • [30] A new backfill material enhancing axial bedding of district heating pipes
    Wagner, B.
    Neidhart, T.