Evaluation of thermal comfort and contamination control for a cleanroom

被引:2
|
作者
Department of Refrigeration and Air-Conditioning, National Chin-Yi University of Technology, Taichung, Taiwan [1 ]
不详 [2 ]
不详 [3 ]
不详 [4 ]
机构
来源
J. Appl. Sci. | 2008年 / 9卷 / 1684-1691期
关键词
Clean rooms - Hosiery manufacture - Laboratories - Thermal comfort;
D O I
10.3923/jas.2008.1684.1691
中图分类号
学科分类号
摘要
There has been a substantial increase in the working environment of cleanroom. Special garments are therefore dressed in all cleanrooms to control particles and microbiological contamination dispersed from personnel in cleanrooms. However, more tightly-woven fabrics of cleanroom garments will result in thermal comfort dissatisfaction. In this study, field tests of a cleanroom have been carried out in our newly constructed MEMS laboratory. The ASHRAE thermal comfort code was conducted to investigate thermal comfort of personnel based on field-testing data consequently. Furthermore, the effects of clothing on thermal comfort and contamination control have been assessed comprehensively. The results from computer simulation and field tests indicated that there existed optimum compromise between the predicted mean vote and airborne particle counts under different cleanroom garments. The contamination control could be achieved by proper types of garments with satisfied thermal comfort of predict mean vote between 0.5-1.0. © 2008 Asian Network for Scientific Information.
引用
收藏
相关论文
共 50 条
  • [1] Investigation of cleanroom clothing thermal insulation by thermal manikin and impact on thermal comfort of cleanroom users
    Konecna, Katerina
    Adamovsky, Daniel
    JOURNAL OF INDUSTRIAL TEXTILES, 2025, 55
  • [2] Evaluation and control of indoor thermal comfort
    Lian, ZW
    Zhao, B
    Ye, XJ
    Liu, HM
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 1119 - 1122
  • [3] Airborne molecular contamination: Cleanroom control strategies
    Higley, JK
    Joffe, MA
    SOLID STATE TECHNOLOGY, 1996, 39 (07) : 211 - &
  • [4] Evaluation of a Thermal-Comfort Control System
    Bermejo, Pablo
    Redondo, Luis
    delaOssa, Luis
    Rodriguez, Daniel
    Julia Flores, M.
    Urea, Carmen
    Gamez, Jose A.
    Martinez-Gomez, Jesus
    Puerta, Jose M.
    ADVANCES IN KNOWLEDGE-BASED AND INTELLIGENT INFORMATION AND ENGINEERING SYSTEMS, 2012, 243 : 746 - 755
  • [5] Improvement of Airflow Distribution and Contamination Control for a Biotech Cleanroom
    Wang, Fujen
    Permana, Indra
    Lee, Kwowhei
    Rakshit, Dibakar
    Rosulindo, Parisya Premiera
    ATMOSPHERE, 2022, 13 (02)
  • [6] PERFORMANCE IMPROVEMENT OF THE AIRFLOW DISTRIBUTION AND CONTAMINATION CONTROL IN A CLEANROOM
    Wang, Fu-Jen
    Wong, King-Leung
    Lai, Chi-Ming
    Sun, Chen-Yi
    Luo, Yuan-Hong
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 376 - 384
  • [7] Method of Particle Contamination Control for Yield Enhancement in the Cleanroom
    Noh, Kwang-Chul
    Lee, Hyeon-Cheol
    Kim, Dae-Young
    Oh, Myung-Do
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2007, 31 (06) : 522 - 530
  • [8] Performance improvement of a biotechnology vaccine cleanroom for contamination control
    Permana, Indra
    Wang, Fujen
    JOURNAL OF BUILDING ENGINEERING, 2024, 82
  • [9] Using an automated cleanroom monitoring system to maximize contamination control
    Livingston, J
    Bower, R
    Pochy, R
    Branst, L
    MICRO, 1997, 15 (09): : 113 - +
  • [10] Thermal comfort evaluation in HVAC Demand Response control
    Kampelis, N.
    Ferrante, A.
    Kolokotsa, D.
    Gobakis, K.
    Standardi, L.
    Cristalli, C.
    SUSTAINABILITY IN ENERGY AND BUILDINGS 2017, 2017, 134 : 675 - 682