Vacuum-arc discharge damage to X-ray framing camera

被引:0
|
作者
Research Center of Laser Fusion, CAEP, B.O. Box 919-986, Mianyang 621900, China [1 ]
不详 [2 ]
机构
来源
Qiangjiguang Yu Lizishu | 2007年 / 2卷 / 321-326期
关键词
Electron emission - Experiments - Field emission - Phosphors - Scattering - Vacuum;
D O I
暂无
中图分类号
学科分类号
摘要
Based on the experiment on the Shenguang-II, the damage of the phosphor and the micro-channel plate of the X-ray framing camera, induced by the vacuum-arc discharge, has been investigated. By measuring the position of the arc on the phosphor and the amplitude of the signal, three kinds of the arc discharges have been distinguished, they are scattered arc, strong arc and fixed arc charges. The damage of the imaging tube and the effect of the working state from the three arc discharges have been compared with different intensity and the different position, respectively. The discharge mechanism is explained with the electron field emission theory, and the stability of the damage is analyzed. The field enhanced coefficient of the fixed arc discharge has been deduced from the experiment result.
引用
收藏
相关论文
共 50 条
  • [41] An experimental study of the dynamics of formation of plasma in a vacuum-arc discharge
    E. F. Prozorov
    K. N. Ul’yanov
    V. A. Fedorov
    High Temperature, 2009, 47 : 158 - 164
  • [42] An experimental study of the dynamics of formation of plasma in a vacuum-arc discharge
    Prozorov, E. F.
    Ul'yanov, K. N.
    Fedorov, V. A.
    HIGH TEMPERATURE, 2009, 47 (02) : 158 - 164
  • [43] NICKEL FERRITE THICK FILMS DEPOSITED BY VACUUM-ARC DISCHARGE
    NAOE, M
    YAMANAKA, S
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1970, 9 (03) : 293 - +
  • [44] The vacuum spark discharge soft X-ray source
    Xu, MS
    Ye, RB
    Guo, XM
    Antoshko, Y
    Drew, S
    Ahtik, I
    Orzechowski, J
    Panarella, E
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS II, 2001, 4502 : 55 - 61
  • [45] OPTIMIZATION OF A VACUUM SPARK DISCHARGE AS AN X-RAY SOURCE
    Bashutin, O. A.
    Vovchenko, E. D.
    Savjolov, A. S.
    Sarantsev, S. A.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2010, (06): : 168 - 170
  • [46] Dilation x-ray framing camera and its temporal resolution uniformity
    Cai, Houzhi
    Fu, Wenyong
    Wang, Dong
    Lei, Yunfei
    Liu, Jinyuan
    OPTICS EXPRESS, 2019, 27 (03): : 2817 - 2827
  • [47] Progress on the development of a single line of sight x-ray framing camera
    Bradley, DK
    Holder, JP
    Damian, CM
    Piston, KW
    Bell, PM
    Dymoke-Bradshaw, AKL
    Hares, JD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 4054 - 4056
  • [48] MULTIPLE-FRAME UV/X-RAY PICOSECOND FRAMING CAMERA
    EAGLES, RT
    SIBBETT, W
    SLEAT, WE
    WALKER, DR
    ALLISON, JM
    FREEMAN, NJ
    ADVANCES IN ELECTRONICS AND ELECTRON PHYSICS, 1988, 74 : 209 - 217
  • [49] Further development of a single line of sight x-ray framing camera
    Holder, JP
    Piston, KW
    Bradley, DK
    Bell, PM
    Dymoke-Bradshaw, AKL
    Hares, JD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 2191 - 2193
  • [50] NANOSECOND X-RAY FRAMING CAMERA FOR DENSE-PLASMA SOURCES
    HELAVA, H
    EICHENBERGER, C
    GILMAN, C
    SCHNEIDER, R
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (08): : 996 - 996