Circuit breaker and transformer monitoring

被引:0
|
作者
Nafar, Mehdi [1 ]
Gheisari, Amirhossein [2 ]
Alesaadi, Alireza [3 ]
机构
[1] Islamic Azad University, Marvdasht Branch, Fars, Iran
[2] Islamic Azad University, Fars Science and Research Branch, Iran
[3] Islamic Azad University, Kazerun Branch, Iran
关键词
Electric circuit breakers - Power transformers - State estimation - Insulation - Partial discharges - Transformer windings - Electric power transmission - Timing circuits - Wavelet transforms - Winding;
D O I
暂无
中图分类号
学科分类号
摘要
Since large power transformers are the most expensive and strategically important components of any power generator and transmission system, their reliability is crucially important for the energy system operation. Also, Circuit breakers are very important elements in the power transmission line so monitoring the events gives a knowledgebase to determine time to the next maintenance. This paper deals with the introduction of the comparative method of the state estimation of transformers and Circuit breakers using continuous monitoring of voltage, current. This paper gives details a new method based on wavelet to apparatus insulation monitoring. In this paper to insulation monitoring of transformer, a new method based on wavelet transformation and neutral point analysis is proposed. Using the EMTP tools, fault in transformer winding and the detailed transformer winding model were simulated. The current of neutral point of winding was analyzed by wavelet transformation. It is shown that the neutral current of the transformer winding has useful information about fault in insulation of the transformer.
引用
收藏
页码:951 / 955
相关论文
共 50 条
  • [21] Experimental and Theoretical Analysis of Vacuum Circuit Breaker Prestrike Effect on a Transformer
    Popov, Marjan
    Smeets, Rene Peter Paul
    van der Sluis, Lou
    de Herdt, Hans
    Declercq, Jan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (03) : 1266 - 1274
  • [22] Transformer Failure Due to Circuit-Breaker-Induced Switching Transients
    Shipp, David D.
    Dionise, Thomas J.
    Lorch, Visuth
    MacFarlane, Bill G.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2011, 47 (02) : 707 - 718
  • [23] A computer simulation of transformer magnetising current interruption by a vacuum circuit breaker
    Chaly, AM
    Chalaya, AT
    ISDEIV - XVIITH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, PROCEEDINGS, VOLS I AND II, 1996, : 249 - 253
  • [24] Effect of Circuit Breaker Shunt Resistance on Chaotic Ferroresonance in Voltage Transformer
    Radmanesh, Hamid
    Rostami, Mehrdad
    ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2010, 10 (03) : 71 - 77
  • [25] APPLICATION OF VACUUM CIRCUIT-BREAKER TO DRY TYPE TRANSFORMER SWITCHING
    OHASHI, H
    MIZUNO, T
    YANABU, S
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (03): : 762 - 762
  • [26] Optically powered air core current transformer for application in circuit breaker
    College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
    Gaoya Dianqi, 2006, 3 (217-219):
  • [27] Overvoltages due to switching off an unloaded transformer with a vacuum circuit breaker
    Popov, M
    Acha, E
    IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (04) : 1317 - 1326
  • [28] Insulative Condition Monitoring of High Voltage Circuit Breaker
    Li Muyi
    Huang Jian
    Hu Xiaoguang
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 1, 2010, : 104 - +
  • [29] Automated Monitoring and Analysis for High Voltage Circuit Breaker
    Huang Jian
    Jiang Xiaofeng
    Hu Xiaoguang
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 1, 2010, : 599 - +
  • [30] Circuit Breaker Duty Monitoring from the Control Center
    Dam, Q. Binh
    Meliopoulos, A. P. Sakis
    2009 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION, VOLS 1-3, 2009, : 1795 - 1800