Icing flashover performance of UHV DC composite insulators at low atmospheric pressure

被引:0
|
作者
State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing 400030, China [1 ]
机构
来源
Zhongguo Dianji Gongcheng Xuebao | 2008年 / 6卷 / 7-12期
关键词
Flashover;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [21] Shed Parameters Optimization of Composite Post Insulators for UHV DC Flashover Voltages at High Altitudes
    Li, Licheng
    Gu, Yu
    Hao, Yanpeng
    Xue, Yiwei
    Xiong, Guokun
    Yang, Lin
    Zhang, Fuzeng
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (01) : 169 - 176
  • [22] DC pollution flashover and rain flashover performance for composite post insulators at high altitudes
    Zhao, Feng
    Zhang, Fuzeng
    Yang, Haolin
    Guan, Zhicheng
    Wang, Liming
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2009, 49 (10): : 1581 - 1584
  • [23] Effects of Electric Field Distribution on Icing and Flashover Performance of 220 kV Composite Insulators
    Hu, Qin
    Yuan, Wei
    Shu, Lichun
    Jiang, Xingliang
    Wang, Shijing
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (05) : 2181 - 2189
  • [24] Influence of Shed Configuration on Icing Characteristics and Flashover Performance of 220 kV Composite Insulators
    Hu, Qin
    Wang, Shijing
    Shu, Lichun
    Jiang, Xingliang
    Qiu, Gang
    Li, Hantao
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (01) : 319 - 330
  • [25] Comparison of AC pollution flashover performances for composite insulators with different configuration under low atmospheric pressure
    Yuan, Qian-Fei
    Shu, Li-Chun
    Jiang, Xing-Liang
    Hu, Qin
    Yang, Zhan-Gang
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (07): : 1662 - 1668
  • [26] Voltage Distribution and Flashover Performance of 220 kV Composite Insulators under Different Icing Conditions
    Lu, Jiazheng
    Xie, Pengkang
    Jiang, Zhenglong
    Fang, Zhen
    Wu, Wei
    ENERGIES, 2018, 11 (03)
  • [27] Influence of Air-gap Characteristics on the Icing Flashover Performance for the Plate Model of Composite Insulators
    Jiang, Hao
    Yang, Guang
    Jia, Zhidong
    Deng, Yu
    Guan, Zhicheng
    Wang, Tianzheng
    Wang, Kangning
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 478 - 481
  • [28] Effects of icing degree on ice growth characteristics and flashover performance of 220 kV composite insulators
    Hu, Qin
    Wang, Shijing
    Yang, Hongjun
    Shu, Lichun
    Jiang, Xingliang
    Li, Hantao
    Qi, Jiahao
    Liu, Yanqing
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2016, 128 : 47 - 56
  • [29] Influence of shed overhangs of composite post insulators in UHV convert stations on dc flashover performances at high altitude
    Gu, Yu
    Hao, Yanpeng
    Xue, Yiwei
    Xiong, Guokun
    Zhang, Fuzeng
    Yang, Lin
    Li, Licheng
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2014, 34 (15): : 2478 - 2484
  • [30] Effect of icing on the AC flashover voltage of 220 kV composite insulators
    Wang, Huan
    Hu, Qin
    Lin, Huiyao
    Xu, Hang
    Shu, Lichun
    Yin, Pancheng
    Jiang, Xingliang
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 238