Study on wind stability and favorable structural scheme of a three-tower cable-stayed bridge

被引:0
|
作者
Zhang, Xinjun [1 ,2 ]
Ni, Binbin [1 ]
Zhao, Tianjiao [1 ]
机构
[1] Zhejiang Univ Technol, Coll Civil Engn, Hangzhou 310023, Peoples R China
[2] Key Lab Civil Engn Struct & Disaster Prevent & Mit, Hangzhou 310023, Peoples R China
关键词
aerodynamic stability; aerostatic stability; design parameter; dynamic characteristics; favorable structural scheme; long-span three-tower cable-stayed bridge;
D O I
10.12989/was.2024.39.5.367
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
By using a computational procedure of three-dimensional aerostatic and aerodynamic stability analysis of long-span bridges, the dynamic characteristics, structural stability including the aerostatic and aerodynamic stability are firstly analyzed for a three-tower cable-stayed bridge with main spans of 1400 meters, the parametric analysis is then conducted, and finally a favorable structural scheme of the example bridge is proposed and confirmed numerically. The results show that long-span three-tower cable-stayed bridge has significant flexibility with less vertical and especially horizontal stiffness, and is sensitive to the transverse wind action; long-span three-tower cable-stayed bridge exhibits a coupled aerostatic instability mode of vertical bending and torsion; the aerodynamic stability is worse than the aerostatic stability for long-span three-tower cable-stayed bridge, the flutter critical wind speed is significantly reduced by the static wind action, and thus the aerostatic effect must be involved in the aerodynamic stability analysis; the best wind stability is obtained for the example bridge as 2 auxiliary piers are set in each side span and their centerline differs from the side piers by 0.4 times the side span length, the center-to-side tower height ratio is 1.3, the tower height-to-span ratio is 1/5, 4 pairs of crossing cables are set at midspan of main spans, and the girder depth is 5.0 m.
引用
收藏
页码:367 / 380
页数:14
相关论文
共 50 条
  • [31] Study on MTMD control of wind-induced vibration for arch steel tower of cable-stayed bridge
    Bai, Hua
    Li, Yu
    Li, Jiawu
    Liu, Jianxin
    Guo, Wei
    Zhongguo Tiedao Kexue/China Railway Science, 2013, 34 (01): : 22 - 28
  • [32] Structural stability of cable-stayed bridges
    Kim, Seungjun
    Won, Deok Hee
    Lee, Keesei
    Kang, Young Jong
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2015, 15 (03) : 743 - 760
  • [33] DYNAMIC STABILITY OF CABLE-STAYED BRIDGE PYLONS
    Michaltsos, G. T.
    Raftoyiannis, I. G.
    Konstantakopoulos, T. G.
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2008, 8 (04) : 627 - 643
  • [34] Structural stability of cable-stayed bridges
    Seungjun Kim
    Deok Hee Won
    Keesei Lee
    Young Jong Kang
    International Journal of Steel Structures, 2015, 15 : 743 - 760
  • [35] ACTIVE CONTROL AND STABILITY OF CABLE-STAYED BRIDGE
    Yang, Jann-Nan
    Giannopolous, Fanis
    1979, 105 (04): : 677 - 694
  • [36] ACTIVE CONTROL AND STABILITY OF CABLE-STAYED BRIDGE
    YANG, JN
    GIANNOPOLOUS, F
    JOURNAL OF THE ENGINEERING MECHANICS DIVISION-ASCE, 1979, 105 (04): : 677 - 694
  • [37] Online structural monitoring of a cable-stayed bridge
    Chang, SP
    Kim, SK
    SMART SYSTEMS FOR BRIDGES, STRUCTURES, AND HIGHWAYS: SMART STRUCTURES AND MATERIALS 1996, 1996, 2719 : 150 - 158
  • [38] Study on Three-Dimensional Visualization of the Cable-Stayed Bridge
    WANG Zi-ru
    ZHANG Fan
    HU Chun-xia
    Computer Aided Drafting,Design and Manufacturing, 2015, (02) : 19 - 22
  • [39] The Structural Form and Development of Cable-Stayed Bridge
    Yu, BaoChu
    Wang, JiaSong
    Ai, Jie
    Sun, RongYang
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN MATERIALS, MECHATRONICS AND CIVIL ENGINEERING (ICAMMCE 2017), 2017, 121 : 61 - 64
  • [40] Model test of composite joint for tower of cable-stayed bridge
    Zhang G.
    Zhang Q.
    Liu Y.
    Li Y.
    Liu, Yuqing (yql@tongji.edu.cn), 1600, Harbin Institute of Technology (49): : 106 - 112