System simulation of a doubly fed induction generator ride-through control for symmetrical grid fault

被引:0
|
作者
School of Electrical Engineering, University of Chongqing, Chongqing 400044, China [1 ]
不详 [2 ]
机构
来源
Zhongguo Dianji Gongcheng Xuebao | 2006年 / 10卷 / 130-135期
关键词
Computer simulation - Electric converters - Electric potential - Pulse width modulation - Stators - Time domain analysis - Voltage control - Wind power - Wind turbines;
D O I
暂无
中图分类号
学科分类号
摘要
Using the time domain simulation model which is experimentally verified, a series of case studies on a representative 2MW DFIG wind turbine system is described. In contrast to the scheme of crowbar protection on the rotor side, integration of the proposed grid fault ride-through control with the normal wind power tracking control allows the DFIG to pick up load immediately after fault clearance and hence improves the post-fault stability of the overall power system. The feasibility region of successful ride-through for symmetrical grid faults is obtained by simulation. The result shows that using the proposed control, a typical DFIG system can successfully ride through a symmetrical fault which brings the system side voltage of the generator transformer down to 0.3 pu, at any operating speed. The effects of pre-fault operation point and machine parameters on the effectiveness of the proposed ride-through control strategy are analyzed. Increasing either the leakage inductance or stator side resistance of the DFIG tends to aid grid fault ride-through control.
引用
收藏
相关论文
共 50 条
  • [41] Doubly-fed induction generator based wind turbines: A comprehensive review of fault ride-through strategies
    Justo, Jackson John
    Mwasilu, Francis
    Jung, Jin-Woo
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 45 : 447 - 467
  • [42] Novel scheme for enhancement of fault ride-through capability of doubly fed induction generator based wind farms
    Vinothkumar, K.
    Selvan, M. P.
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (07) : 2651 - 2658
  • [43] IMC robust control for high-voltage ride-through of doubly fed induction wind generator
    Ma, Xiaoyang
    Yang, Honggeng
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2018, 13 (09) : 1265 - 1275
  • [44] Safety Voltage Control Strategy for High Voltage Ride-Through of Doubly Fed Induction Generator (DFIG)
    He Zehua
    PROCEEDINGS OF THE 2015 INTERNATIONAL POWER, ELECTRONICS AND MATERIALS ENGINEERING CONFERENCE, 2015, 17 : 562 - 566
  • [45] The Influence of the Applied Rotor Voltage on Ride-Through Capability of Doubly Fed Induction Generator
    Salles, Mauricio B. C.
    Grilo, Ahda P.
    Cardoso, Jose Roberto
    Lessa, Ludwig Lopez
    2011 INTERNATIONAL CONFERENCE AND UTILITY EXHIBITION ON POWER AND ENERGY SYSTEMS: ISSUES & PROSPECTS FOR ASIA (ICUE), 2011,
  • [46] Dynamic Coupling and Cooperative Control for Multi-Paralleled Doubly Fed Induction Generator Wind Farms During Symmetrical Low Voltage Ride-Through in a Weak Grid
    Guan, Lei
    Yao, Jun
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2024, 9 (03) : 112 - 125
  • [47] Low voltage ride-through control of doubly-fed induction generator wind turbines with a series grid-side converter
    Yao, Jun
    Liao, Yong
    Li, Hui
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (06): : 98 - 103
  • [48] Review of low voltage ride-through technology of doubly-fed induction generator
    Niu, Lele
    Wang, Xiao
    Wu, Linlin
    Yang, Feng
    Xu, Man
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 3106 - 3108
  • [49] Control Algorithm for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Fault Ride Through and Unbalanced Grid Conditions
    Suh, Yongsug
    Park, Yonggyun
    Go, Yuran
    2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 2396 - 2403
  • [50] A fault ride through scheme for doubly fed induction generator wind turbine
    Ling Y.