Finite element analysis of the effects of a floating mass transducer on the performance of a middle ear implant

被引:4
|
作者
Liu H. [1 ]
Rao Z. [1 ]
Ta N. [1 ]
机构
[1] State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, 200240, Shanghai
来源
基金
中国国家自然科学基金;
关键词
Finite element modeling; Floating mass transducer; Middle ear implant;
D O I
10.3109/03091902.2010.481033
中图分类号
学科分类号
摘要
Experimental evidence has shown that floating mass transducers (FMTs) play a key role in the performance of middle ear implants. However, because of the tiny size and complex structure of the middle ear, systematic experimental study of the influences of FMTs is difficult to carry out. In this paper we develop a FMT-attached middle-ear finite element model to investigate some effects of a FMT on the performance of a middle ear implant. This model was constructed based on a complete set of computerized tomography section images of a healthy volunteer's left ear. The validity of the developed model was verified by comparing the model-predicted motion of the tympanic membrane and stapes footplate with published experimental data. The result shows that the FMT produces a mass loading effect prominently at high frequencies, the force required to drive the incus to the equivalent of 100 dB sound pressure level (SPL) is about 89μN, and setting the attachment position of the FMT close to the incudostapedial joint can enhance the driving effect. © 2010 Informa UK Ltd.
引用
收藏
页码:316 / 323
页数:7
相关论文
共 50 条
  • [31] Finite element analysis of auditory characteristics in patients with middle ear diseases
    Tu, Bo
    Li, Xiaoping
    Nie, Zhenhua
    Shi, Changzheng
    Li, Hengguo
    ACTA OTO-LARYNGOLOGICA, 2017, 137 (07) : 700 - 706
  • [32] Finite element analysis of the middle ear transfer functions and related pathologies
    Zhao, Fei
    Koike, Takuji
    Wang, Jie
    Sienz, Hans
    Meredith, Rhys
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (08) : 907 - 916
  • [33] Prediction of a Mysticete Audiogram via Finite Element Analysis of the Middle Ear
    Tubelli, Andrew
    Zosuls, Aleks
    Ketten, Darlene
    Mountain, David C.
    EFFECTS OF NOISE ON AQUATIC LIFE, 2012, 730 : 57 - 59
  • [34] Influence of Floating-Mass Transducer Coupling Efficiency for Active Middle-Ear Implants on Speech Recognition
    Mueller, Alexander
    Mir-Salim, Parwis
    Zellhuber, Nina
    Helbig, Ralf
    Bloching, Marc
    Schmidt, Tobias
    Koscielny, Sven
    Dziemba, Oliver C.
    Plontke, Stefan K.
    Rahne, Torsten
    OTOLOGY & NEUROTOLOGY, 2017, 38 (06) : 809 - 814
  • [35] Parameter study on a finite element model of the middle ear
    Hoffstetter, Marc
    Schardt, Florian
    Lenarz, Thomas
    Wacker, Sabine
    Wintermantel, Erich
    BIOMEDIZINISCHE TECHNIK, 2010, 55 (01): : 19 - 26
  • [36] Finite element modeling of human ear with external ear canal and middle ear cavity
    Gan, RZ
    Sun, Q
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 264 - 265
  • [37] Verification of Vibration Characteristic of Hermetically Sealed Differential Floating Mass Transducer for Implantable Middle Ear Hearing Device using Mock-up of Ear
    Kim, Min Woo
    Seong, Ki Woong
    Lim, Hyung Gyu
    Jung, Eui Sung
    Lee, Jang Woo
    Kim, Dong Wook
    Lee, Myoung Won
    Han, Ji Hun
    Lee, Jyung Hyun
    Cho, Jin Ho
    2008 INTERNATIONAL SYMPOSIUM ON INTELLIGENT INFORMATION TECHNOLOGY APPLICATION, VOL III, PROCEEDINGS, 2008, : 839 - +
  • [38] Finite element analysis of a floating microstimulator
    Sahin, Mesut
    Ur-Rahman, Syed S.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2007, 15 (02) : 227 - 234
  • [39] Effects of piezoelectric material on the performance of Tonpilz transducer using finite element method
    Seo, Jin-Won
    Choi, Kyoon
    Lee, Ho-Yong
    JOURNAL OF THE KOREAN CRYSTAL GROWTH AND CRYSTAL TECHNOLOGY, 2016, 26 (04): : 139 - 144
  • [40] Design study of a Miniaturized Displacement Transducer (MDT) for an active middle ear implant system
    Kaltenbacher, D.
    Schaechtele, J.
    Goll, E.
    Burkhardt, C.
    Arnold, H.
    Dalhoff, E.
    Zenner, H-P.