Minimum grid involvement-based control of a grid-connected PV-battery system using nine switch converter

被引:0
|
作者
Pati, Swagat [1 ]
Nanda, Amar Bijay [1 ]
Osumanu, Futa [2 ]
Sahu, Binod [1 ]
Choudhury, Abhijeet [1 ]
机构
[1] SOADU, ITER, Dept Elect Engn, Bhubaneswar, India
[2] Accra Tech Univ, Dept Elect Elect Engn, Accra, Ghana
关键词
Battery; Central power management algorithm (CPMA); Grid; Microgrid; Minimum grid involvement; Nine-switch converter (NSC); 9-SWITCH CONVERTER; MODULATION METHOD; MICROGRIDS; STRATEGIES; MANAGEMENT;
D O I
10.1016/j.compeleceng.2024.109941
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Grid-connected microgrid systems often face cost, intermittency, and regulatory issues. However, developing an effective central power management algorithm (CPMA) and supportive power control strategies can help mitigate these disadvantages. This article proposes a power management system for a nine-switch converter (NSC) based photovoltaic-battery on/off-grid system, which cleverly minimizes the grid interaction, reducing the losses occurring at the filter inductors and increasing system efficiency without compromising the system reliability and cost. This article emphasizes the operation of NSC to achieve seamless transitions between various operating modes of the grid-PV battery system. For that, two separate control structures are developed in this work to control the two ports of the NSC. Where the grid side port is controlled using a decoupled current control strategy, the load side port is controlled using a voltage control structure, in this article, a CPMA is developed to achieve minimum grid involvement under all operating conditions. The PV system has an MPPT algorithm to extract maximum power from the PV unit. A bidirectional DC-DC converter interfaces the low voltage (900 V) battery and the NSC's high voltage (1.5 kV - 2 kV) DC link. The entire operating condition of the proposed system (with/ without grid connectivity) is divided into eight modes. The CPMA acts as the logic to select the operating mode of the system. Besides that, this work also takes measures to reduce the DC link voltage requirement of the NSC. The system's performance is evaluated with variable irradiance conditions and at different battery SOC levels for both on-grid and off-grid. The effects of nonlinear loads on the system performance are also studied both during on-grid and islanded modes of operation. The grid currents remain unaffected by the effects of nonlinear load currents. Though the switching of nonlinear load causes an increase in THD of the load voltage, the load voltage THD remains well below the 5 % limits. The system is developed using Matlab/ Simulink and verified using the OPAL-RT 4510 simulator.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Optimal engagement and operation of a grid-connected PV/battery system
    N'Goran, Arnold
    Daugrois, Bruno
    Lotteau, Marc
    Demassey, Sophie
    PROCEEDINGS OF 2019 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT-EUROPE), 2019,
  • [32] Holistic Control Approach for the Grid-Connected Converter of a Battery Energy Storage System
    Nunez, Ciro
    Visairo-Cruz, Nancy
    Arellanes, Alberto
    Mora, Dante
    Segundo, Juan
    IEEE ACCESS, 2020, 8 (08): : 216844 - 216855
  • [33] An Asymmetrical Reduced Switch Multilevel Inverter based Grid-connected PV system
    Kumar, Madan Das
    Mishra, Sukumar
    Jana, Karthick Chandra
    Buduma, Parasharamulu
    2020 3RD INTERNATIONAL CONFERENCE ON ENERGY, POWER AND ENVIRONMENT: TOWARDS CLEAN ENERGY TECHNOLOGIES (ICEPE 2020), 2021,
  • [34] Implementation and investigation of a solar and wind energy-based grid-connected hybrid system with nine switch converter
    Datta, Subir
    Das, Sumana
    Samanta, Soumya
    Chhangte, Lalremruati
    Deb, Subhasish
    Singh, Robert
    Adhikari, Shuma
    Hassan, Abdurrahman Shuaibu
    Ustun, Taha Selim
    ENERGY EXPLORATION & EXPLOITATION, 2025, 43 (02) : 492 - 513
  • [35] A Rule-based Power Management Controller using Stateflow for Grid-Connected PV-Battery Energy System supplying Household load
    Kermadi, Mostefa
    Salam, Zainal
    Berkouk, El Madjid
    2018 9TH IEEE INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2018,
  • [36] Assessing Degradation-Aware Model Predictive Control for Energy Management of a Grid-Connected PV-Battery Microgrid
    Li, Alan Gen
    Preindl, Matthias
    2022 IEEE/AIAA TRANSPORTATION ELECTRIFICATION CONFERENCE AND ELECTRIC AIRCRAFT TECHNOLOGIES SYMPOSIUM (ITEC+EATS 2022), 2022, : 546 - 551
  • [37] Short-term scheduling of battery in a grid-connected PV/battery system
    Lu, B
    Shahidehpour, M
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (02) : 1053 - 1061
  • [38] Simulation of Fuzzy Logic Based Energy Management for the Home with Grid Connected PV-Battery System
    Soetedjo, Aryuanto
    Nakhoda, Yusuf Ismail
    Saleh, Choirul
    2018 2ND INTERNATIONAL CONFERENCE ON SMART GRID AND SMART CITIES (ICSGSC 2018), 2018, : 122 - 126
  • [39] Grid Connected PV System using Cuk Converter
    Syam, M. S.
    Kailas, T. Sreejith
    2013 ANNUAL INTERNATIONAL CONFERENCE ON EMERGING RESEARCH AREAS & 2013 INTERNATIONAL CONFERENCE ON MICROELECTRONICS, COMMUNICATIONS & RENEWABLE ENERGY (AICERA/ICMICR), 2013,
  • [40] Assessment of Grid-connected Residential PV-Battery Systems in Sweden - A Techno-economic Perspective
    Kabir, Md Ahsan
    Sunny, Mahmood Reaz
    Siddique, Md Nazrul Islam
    2021 IEEE INTERNATIONAL CONFERENCE IN POWER ENGINEERING APPLICATION (ICPEA 2021), 2021, : 73 - 78