Application of electromagnetic vector sensor for partial discharge on-line monitoring of transformer

被引:0
|
作者
Zhou, Lixing
Li, Weiguo
机构
[1] College of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha 410076, China
[2] School of Electrical Engineering, Wuhan University, Wuhan 430072, China
[3] School of Electrical Engineering, North China of Electrical Power University, Beijing 102206, China
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Partial discharge (PD) sources identification and orientation is one of the key problems for PD online monitoring of transformers. Electromagnetic vector sensor (EMVS) has been successfully applied to estimate the electromagnetic sources spatial parameters and polarizations. In this paper, a single EMVS is proposed to measure the ultra-high frequency (UHF) signal for PD detection and orientation. With its output data processed by a narrow-band filter, the number of PD sources can be estimated exactly by using minimal describing length (MDL) rule or smoothed rank sequence (SRS) method, based on which, the spatial parameters and polarizations of PD sources can be obtained by adopting MUSIC algorithm to estimate the spatial spectrum of the data's covariance matrix. The results of simulate experiment show that this method is capable of identifying three PD sources and estimating their azimuth, elevation and polarization. It is practical and hopeful to realize the PD orientation in transformer online PD monitoring.
引用
收藏
页码:37 / 40
相关论文
共 50 条
  • [21] GIT partial discharge UHF on-line monitoring system
    Zhang, Xiao-Xing
    Wang, Zhen
    Tang, Ju
    Liu, Lei
    Wei, Yan
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (07): : 1692 - 1697
  • [22] Partial discharge on-line monitoring in switchgears and bus ducts
    Berler, Z
    Blokhintsev, I
    Golubev, A
    ICSD '01: PROCEEDINGS OF THE 2001 IEEE 7TH INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, 2001, : 355 - 360
  • [23] On-line Partial Discharge Monitoring of Substation Power Transformers
    Huzmezan, Mihai
    2022 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2022, : 347 - 352
  • [24] On-line partial discharge calibration and monitoring for power transformers
    Farag, AS
    Shewhdi, MH
    Jin, X
    Wang, C
    Cheng, TC
    Dong, X
    Gao, S
    Jing, W
    Wang, Z
    ELECTRIC POWER SYSTEMS RESEARCH, 1999, 50 (01) : 47 - 54
  • [25] An on-line Monitoring Method for Vibration and Partical Discharge of Power Transformer
    Guan, Qiao
    Liu, Xingwei
    Xi, Baofeng
    2021 8TH INTERNATIONAL FORUM ON ELECTRICAL ENGINEERING AND AUTOMATION, IFEEA, 2021, : 396 - 399
  • [26] Partial discharge sources detection and location with an electromagnetic vector sensor
    Zhou, Lixing
    Li, Weiguo
    ICIEA 2006: 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, PROCEEDINGS, 2006, : 1671 - 1675
  • [27] Partial discharge sources detection and location with an electromagnetic vector sensor
    Zhou, Lixing
    Li, Weiguo
    2006 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, 2006, : 615 - +
  • [28] An improved adaptive normalized least mean square filtering algorithm for on-line monitoring of transformer partial discharge
    Lei, Yun-Fei
    Yang, Gao-Cai
    Liu, Sheng-Xiang
    Dianwang Jishu/Power System Technology, 2010, 34 (08): : 165 - 169
  • [29] Development of UHF Transformer Probe Sensors for On-Line Partial Discharge Measurement
    Reid, Alistair
    Judd, Martin
    Johnstone, Carl
    UPEC: 2009 44TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, 2009, : 40 - +
  • [30] A Cost Effective Trigger Circuit for an On-line Multi-sensor Partial Discharge Monitoring System
    Al Zaabi, M.
    Salah, Muaz
    Qasim, M.
    El-Hag, Ayman
    Yesildirek, Aydin
    CONFERENCE RECORD OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2012, : 104 - 107