Small signal stability analysis of the large-scale wind farm with DFIGs

被引:0
|
作者
Wang, Chen [1 ]
Shi, Li-Bao [1 ]
Yao, Liang-Zhong [2 ]
Wang, Li-Ming [1 ]
Ni, Yi-Xin [1 ]
机构
[1] National Key Laboratory of Power Systems in Shenzhen, Tsinghua University, Shenzhen 518055, China
[2] AREVA T and D Technology Centre, Stafford ST17 4LX, United Kingdom
关键词
Electric power system interconnection - Electric fault currents - Electric power system control - Asynchronous generators - Electric power system stability - Vector control (Electric machinery) - Signal analysis - Electric power transmission networks - Electric utilities - Stators;
D O I
暂无
中图分类号
学科分类号
摘要
The impact of high penetration of grid- connected wind farms with doubly-fed induction generators (DFIG) on power system small signal stability is systematically assessed. A practical electromechanical transient model is established via employing the stator-flux-oriented vector control scheme. Similarly, the stator-flux-oriented vector control scheme is used to implement the decoupled control of active and reactive power in modeling the rotor-side converter controller. According to the derived DFIG models, the corresponding state matrix related to the small signal stability analysis with grid-connected wind farms of the DFIG type is deduced. Finally, the 10-generator 39-bus New England test system is applied to assess the effect of the large wind farm on power system small signal stability, and some preliminary conclusions are drawn. © 2010 Chin. Soc. for Elec. Eng.
引用
收藏
页码:63 / 70
相关论文
共 50 条
  • [41] NUMERICAL ANALYSIS OF A LARGE-SCALE HYDRAULIC WIND FARM WITH INTEGRATED HYDRAULIC ENERGY STORAGE
    Buhagiar, Daniel
    Sant, Tonio
    PROCEEDINGS OF THE ASME 10TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2016, VOL 1, 2016,
  • [42] Control Strategy of Improving the Transient Voltage Stability of Grid-connected Large-scale Wind Farm
    Lu, Jinling
    Shi, Shaotong
    Lu, Yang
    RENEWABLE ENERGY AND ENVIRONMENTAL TECHNOLOGY, PTS 1-6, 2014, 448-453 : 1758 - 1761
  • [43] Installation SVC to Improve Output Active Power of Large-scale Wind Farm Based on the Transient Stability
    Wu Yanjuan
    Li Linchuan
    Zhang Fang
    2012 POWER ENGINEERING AND AUTOMATION CONFERENCE (PEAM), 2012, : 201 - 203
  • [44] Impact of Electric Vehicle Load and Wind Farm on Small Signal Stability
    Bhukya, Jawaharlal
    Yadav, Ashiwani
    Sharma, Poorva
    2020 5TH IEEE INTERNATIONAL CONFERENCE ON RECENT TRENDS ON ELECTRONICS, INFORMATION, COMMUNICATION & TECHNOLOGY (RTEICT-2020), 2020, : 46 - 51
  • [45] Small-signal stability-constrained optimal power flow analysis of multiterminal VSC-HVDC systems with large-scale wind farms
    Kim, Sangwon
    Yokoyama, Akihiko
    Takaguchi, Yusuke
    Takano, Tomihiro
    Mori, Kazuyuki
    Izui, Yoshio
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2019, 14 (07) : 1033 - 1046
  • [46] The Small Signal Stability Analysis of A Power System Integrated with PMSG-based Wind Farm
    Wei, Zhaoyang
    Song Shaojian
    2014 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2014, : 267 - 271
  • [47] Small Signal Stability Analysis with Penetration of Grid-connected Wind Farm of PMSG Type
    Masoud BAZARGAN
    电力系统自动化, 2012, 36 (08) : 171 - 177
  • [48] Analysis on static voltage stability of system with large-scale wind power integration
    Xiong, Chuan-Ping
    Zhang, Xiao-Hua
    Meng, Yuan-Jing
    Xiong, Hao-Qing
    Zeng, Bing
    Sun, Hua-Dong
    Yi, Jun
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2012, 40 (21): : 132 - 137
  • [49] SSR Characteristics Study considering DFIGs at Different Locations in Large Wind Farm
    Dong, Xiaoliang
    Zang, Wei
    Dong, Cun
    Xu, Tian
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [50] Investigation on the integral output power model of a large-scale wind farm
    Bao N.
    Ma X.
    Ni W.
    Frontiers of Energy and Power Engineering in China, 2007, 1 (1): : 67 - 78