Study of the Flicker Phenomenon Induced in the Electric Arc Furnace of the Steel Factory in Tunisia

被引:0
|
作者
Tlili, Faouzi [1 ]
Ben Slimene, Marwa [2 ]
Khlifi, Mohamed Arbi [3 ]
Bacha, Faouzi [1 ,4 ]
机构
[1] Carthage Univ, LISI Lab, INSAT, Carthage 1054, Tunisia
[2] Univ Hail, Coll Comp Sci & Engn, Dept Comp Sci & Engn, Hail 55476, Saudi Arabia
[3] Islamic Univ Madinah, Dept Elect Engn, Madinah 42351, Saudi Arabia
[4] Univ Tunis, Natl Higher Engn Sch Tunis ENSIT, Dept Elect Engn, Tunis 1008, Tunisia
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Flicker severity; flickermeter; arc furnace; flicker; MITIGATION;
D O I
10.1109/ACCESS.2024.3502428
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper investigates the phenomenon of flicker induced in the Tunisian steel factory's electric arc furnace (EAF). Therefore, several solutions have been proposed in the literature in order to mitigate this phenomenon. We cite the three famous techniques; the addition of an inductor in series with the electric arc furnace, the use of the Flexible Alternating Current Transmission Systems (FACTS) systems and the increase in the short-circuit power of the electric arc furnace. The final solution was selected based on a number of factors, including its lower cost and simpler plant installation dimension in comparison to the other two options. Above all, the high maintenance costs associated with the FACTS and the extremely careful sizing of the complete plant infrastructure. In fact, this study is subdivided into two parts. First, the first part will be devoted to the theoretical study of flicker while describing its admissible limits according to the standards in order not to disturb equipment or human beings. However, the 2(nd) part of the paper is subdivided into two sections. The first section deals with the evolution of flicker severity levels short and long term before and after increasing the short-circuit power of the electric arc furnace. However, the second section deals with the experimental tests and implements the measurement of the flicker severity generated by the electric arc furnace using a Megger PA-9 Plus flickermeter after increasing the short-circuit power of the electric arc furnace. In fact, the implementation of these tests was carried out following the cooperation of the Tunisian electricity and gas company and the national higher school of engineers of Tunis on the one hand and the steel factory in Manzel Bourguiba Tunisia on the other hand.
引用
收藏
页码:174850 / 174858
页数:9
相关论文
共 50 条
  • [31] A Time-Domain AC Electric Arc Furnace Model for Flicker Planning Studies
    Horton, Randy
    Haskew, Timothy A.
    Burch, Reuben F., IV
    IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (03) : 1450 - 1457
  • [32] Modeling of Electric Arc Furnace & Control Algorithms for voltage flicker mitigation using DSTATCOM
    Anuradha, K.
    Muni, B. P.
    Kumar, A. D. Raj
    2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 1606 - +
  • [33] Modeling Electric Arc Furnace to Estimate Flicker Levels in Power Systems Using ATP
    Estrada-Villa, G. R.
    Cano-Plata, E. A.
    Ustariz-Farfan, A. J.
    2014 IEEE 16TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2014, : 410 - 414
  • [34] Modeling FACTS Device Impact on Voltage Flicker in the Electric Arc Furnace Supply System
    Varetsky, Yuriy
    Konoval, Volodymyr
    2019 IEEE 20TH INTERNATIONAL CONFERENCE ON COMPUTATIONAL PROBLEMS OF ELECTRICAL ENGINEERING (CPEE), 2019, : 244 - 247
  • [35] Voltage flicker analysis and mitigation-case study in AC Electric Arc Furnace using PSCAD/EMTDC
    Sharmeela, C
    Uma, G
    Mohan, MR
    Karthikeyan, K
    2004 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - POWERCON, VOLS 1 AND 2, 2004, : 707 - 712
  • [36] Use of active power filter to reduce flicker caused by electric arc furnace operation
    Cernan, Martin
    Bejvl, Martin
    Simek, Petr
    Valouch, Viktor
    2022 22ND INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2022, : 8 - 12
  • [37] MANAGEMENT OF MATERIAL FLOWS IN THE STEEL INDUSTRY. CASE STUDY: ELABORATION OF STEEL IN AN ELECTRIC ARC FURNACE
    Farcean, Ioana
    Prostean, Gabriela
    Ardelean, Erika
    ACTA TECHNICA NAPOCENSIS SERIES-APPLIED MATHEMATICS MECHANICS AND ENGINEERING, 2024, 67 (02): : 323 - 332
  • [38] Characterisation study of different electric arc furnace steel slags for usage in wastewater treatment
    Forsido, Tedlaye
    Mccrindle, Rob I.
    Maree, Jannie
    Mpenyana-Monyatsi, Lizzy
    INTERNATIONAL JOURNAL OF ENVIRONMENT AND WASTE MANAGEMENT, 2025, 36 (02)
  • [39] Electric arc furnace dust injection into iron and steel melts
    Dofasco Inc., Hamilton, Ont.
    不详
    Can Metall Q, 2006, 1 (1-8):
  • [40] Heavy Metals in Steel Mill Electric Arc Furnace Dust
    Sofilc, T.
    Cerjan-Stefanovic, S.
    Mandrino, Dj.
    Rastovcan-Mioc, A.
    Mioc, B.
    KEMIJA U INDUSTRIJI-JOURNAL OF CHEMISTS AND CHEMICAL ENGINEERS, 2005, 54 (12): : 505 - 512