Simulation for self-extinction behavior of secondary arc in transmission lines

被引:1
|
作者
机构
[1] Yan, Xianglian
[2] Chen, Weijiang
[3] Li, Zhibing
[4] Wang, Chengyu
[5] He, Ziming
来源
Yan, X. (yanxl@epri.sgcc.com.cn) | 1600年 / Science Press卷 / 38期
关键词
Equivalent circuits - Iterative methods - Parameter estimation - Electric power transmission;
D O I
10.3969/j.issn.1003-6520.2012.10.035
中图分类号
学科分类号
摘要
The self-extinguishing behavior of secondary arcs affects the single-phase re-closure time of transmission lines, so it is important to improve the power system's transmission capacity and reliability. Based on the classic Mayr arc model, the non-linear time-varying arc resistance was introduced to describe the condition of an arc channel, and the arc resistance equations were established. By analyzing the movement characteristics of the secondary arc, the arc's real time length was obtained to iteratively compute the arc resistance. Then an arc resistance criterion was proposed to judge whether arc extinguishes by itself or not according to the law of energy conservation. The equivalent circuit of the arc resistance connected with the system circuit was also put forward to calculate the arc characteristics, and the simulation flow for the self-extinguishing behavior of the secondary arc was further expressed in detail. With the arcing test data at low currents, the parameter estimation was performed for this arc model, and some waveforms of arc voltage, current, resistance and arcing duration were obtained. According to the obtained results, the potential gradient of secondary arc is in a range of 1500~2000 V/m. The calculation waveforms are close to the test results, and the arcing duration error is within the permission error of engineering. It is concluded that the presented secondary arc model and its simulation method are reasonable and practicable.
引用
收藏
相关论文
共 50 条
  • [21] Developed Model and Simulation of Primary and Secondary Arc Fault on Transmission Lines Using MATLAB
    ElRefaie, Hesham B.
    Negm, Emtethal
    Abd El Razik, Mohamed
    Negm, Tarek S.
    2017 NINETEENTH INTERNATIONAL MIDDLE-EAST POWER SYSTEMS CONFERENCE (MEPCON), 2017, : 965 - 970
  • [22] Self-extinction of methanol fire in tunnel with different configuration of blocks
    You, Shu-Hang
    Wang, Kai-Hong
    Shi, Jia-Kang
    Chen, Zi-Nan
    Gao, Dongli
    Chen, Jun-Min
    Lin, Peng
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 98
  • [23] SELF-EXTINCTION OF ARCS CREATED IN LONG AIR GAPS
    ANJO, K
    TERASE, H
    KAWAGUCHI, Y
    ELECTRICAL ENGINEERING IN JAPAN, 1968, 88 (04) : 83 - +
  • [24] On the self-extinction time of pool fire in closed compartments
    Zhang, Jiaqing
    Lu, Shouxiang
    Li, Changhai
    Yuan, Man
    Yuen, Richard
    9TH ASIA-OCEANIA SYMPOSIUM ON FIRE SCIENCE AND TECHNOLOGY, 2013, 62 : 266 - 274
  • [25] Detection of secondary arc extinction and auto-reclosing in compensated AC transmission lines based on machine learning
    Arefaynie, Abraham D.
    Saad, Muhammad
    Kim, Chul-Hwan
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 223
  • [26] Secondary Arc Extinction of Single Pole Auto-Reclosing on EHV Transmission Lines with Shunt Compensation Reactors
    Babu, Gireesh
    Ramesh, M., V
    2012 INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN ELECTRICAL ENGINEERING AND ENERGY MANAGEMENT (ICETEEEM - 2012), 2012, : 52 - 58
  • [27] An, experimental study on self-extinction of methanol fire in tilted tunnel
    Lin, Peng
    Wang, Zhong-Kuan
    Wang, Kai-Hong
    Gao, Dong-li
    Shi, Jia-Kang
    You, Shu-Hang
    Chen, Zi-Nan
    Wang, Guo-Yuan
    Mei, Xiu-Juan
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2019, 91
  • [30] A Study on the Transient of Secondary Arc Current of UHV Transmission Lines
    Sun, Qiuqin
    Xiao, Zhibin
    Liu, Hongshun
    Li, Qingmin
    Wang, Feng
    IEEE ACCESS, 2018, 6 : 38616 - 38626