Optical system design of broadband astigmatism-free Czerny-turner spectrometer

被引:0
|
作者
Zhao, Yiyi [1 ,2 ]
Yang, Jianfeng [1 ]
Xue, Bin [1 ]
Yan, Xingtao [1 ,2 ]
机构
[1] Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119, China
[2] University of Chinese Academy of Sciences, Beijing 100049, China
关键词
Astigmatism-corrected - Broadband - Correction method - Cylindrical lens - Czerny-Turner spectrometer - Development trends - Micro-spectrometer - Simple structures;
D O I
暂无
中图分类号
学科分类号
摘要
For the development trend of miniaturization and high-resolution of spectrometer, an optical design with a simple structure, broadband, astigmatism-corrected micro spectrometer was designed. The principle and correction method of the aberration of crossed beam Czerny-turner spectrometer were analyzed in detail. The broadband astigmatism-corrected theory equations using cylindrical lens were deduced. For example, a micro spectrometer operating in 300-900 nm with an object NA of 0.08 has been designed. This spectrometer adopted crossed beam structure to minish its volume and used a cylindrical lens to remove astigmatism over the full bandwidth. The analyzed results demonstrated that this spectrometer with compact configuration and small volume corrected the astigmatism in the wide spectral region. The resolution of the spectrometer was better than 0.5 nm in the whole spectral region.
引用
收藏
页码:1182 / 1187
相关论文
共 50 条
  • [31] Broadband astigmatism-free Offner imaging spectrometer with high resolution
    Lin, Jing
    Wu, Su
    Yu, Lei
    APPLIED OPTICS, 2020, 59 (04) : 1110 - 1116
  • [32] Design of FUV imaging spectrometer based on crossed Czerny-Turner structure
    Wu, Yan
    Tang, Yi
    Ni, Guoqiang
    2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTICAL SYSTEMS AND OPTOELECTRONIC INSTRUMENTS, 2009, 7156
  • [33] CZERNY-TURNER MONOCHROMATOR - ASTIGMATISM IN THE CLASSICAL AND IN THE CROSSED BEAM DISPOSITIONS
    SIMON, JM
    GIL, MA
    FANTINO, AN
    APPLIED OPTICS, 1986, 25 (20): : 3715 - 3720
  • [34] General study of asymmetrical crossed Czerny-Turner spectrometer
    Tang, Ming
    Fan, Xianguang
    Wang, Xin
    Xu, Yingjie
    Que, Jing
    He, Jian
    APPLIED OPTICS, 2015, 54 (33) : 9966 - 9975
  • [35] Structural Optimization Design and Analysis of M-Type Czerny-Turner Spectrometer
    Wu Yunpeng
    Wang Jun
    LASER & OPTOELECTRONICS PROGRESS, 2022, 59 (11)
  • [36] Optimization of freeform cylindrical lens in Czerny-Turner spectrometer system to correct the astigmatism by using user defined error function
    Qu, Bixiang
    Xia, Guo
    Yu, Feihong
    6TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: ADVANCED OPTICAL MANUFACTURING TECHNOLOGIES, 2012, 8416
  • [37] Optical Spectrometer Design of Combined Unfolded Czerny-Turner Spectrometer Sharing One Common Linear-array Detector
    Guo Pan
    Deng Yanbao
    Wang Lifu
    Chen Siying
    Tan Wangshu
    Zhang Yinchao
    Sun Yuting
    Zhang Jiayi
    Yang Wenhui
    Chen He
    ACTA PHOTONICA SINICA, 2022, 51 (06)
  • [38] Coma and Resolution in Wide Spectral Region Czerny-Turner Spectrometer
    Chen Tan-xuan
    Yang Huai-dong
    Chen Ke-xin
    Tan Qiao-feng
    Jin Guo-fan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (06) : 1692 - 1696
  • [39] Analysis of spectral resolution of a portable cross Czerny-Turner spectrometer
    Zhang, Guodong
    Lin, Hui
    INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS, PTS 1-4, 2013, 241-244 : 449 - 456
  • [40] Comparative assessment of astigmatism-corrected Czerny-Turner imaging spectrometer using off-the-shelf optics
    Yuan, Qun
    Zhu, Dan
    Chen, Yueyang
    Guo, Zhenyan
    Zuo, Chao
    Gao, Zhishan
    OPTICS COMMUNICATIONS, 2017, 388 : 53 - 61