Retrofitting Natural Gas-Fired Boiler for Hydrogen Combustion: Operational Performance and NOx Emissions

被引:0
|
作者
Nemitallah, Medhat A. [1 ,2 ,3 ,4 ]
Aliyu, Mansur [1 ]
Hamdy, Mohamed [1 ]
Habib, Mohamed A. [1 ,5 ]
机构
[1] King Fahd Univ Petr & Minerals, Interdisciplinary Res Ctr Hydrogen Technol & Carb, Dhahran 31261, Saudi Arabia
[2] King Fahd Univ Petr & Minerals, Dhahran 31261, Saudi Arabia
[3] King Fahd Univ Petr & Minerals, SDAIA KFUPM Joint Res Ctr Artificial Intelligence, Dhahran 31261, Saudi Arabia
[4] KA CARE Energy Res & Innovat Ctr Dhahran, Dhahran 31261, Saudi Arabia
[5] King Fand Univ Petr & Minerals, Mech Engn Dept, Dhahran 31261, Saudi Arabia
来源
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME | 2024年 / 146卷 / 10期
关键词
hydrogen combustion; industrial boilers; NOx emissions; environmental performance; modelling; air emissions from fossil fuel combustion; alternative energy sources; energy conversion/systems; hydrogen energy; POWER-TO-GAS; METHANE; STABILITY; MIXTURES; FUTURE; BURNER; AIR;
D O I
10.1115/1.4065205
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The effects of hydrogen fraction (HF: volumetric fraction of H-2 in the fuel mixture of CH4 + H-2) from 0% to 100% by volume, on the thermal and environmental performance of a 207-MW industrial water tube boiler, are investigated numerically at a fixed excess air factor, lambda = 1.15. This study aims to determine the hardware modifications required for boilers to be retrofitted for pure hydrogen operation and investigates how NOx emissions are affected by hydrogen enrichment. The results showed insignificant increases in maximum combustion temperature with increasing the HF, though the distributions of temperature profiles are distinct. In reference to the basic methane combustion, H-2 flames resulted in a positive temperature rise in the vicinity of the burner. Increasing the HF from 0% to 2% resulted in higher average thermal NOx emissions at the boiler exit section from 37 up to 1284 ppm, then it decreased to 1136 ppm at HF = 30%, and later it leveled up to 1474 ppm at HF = 100%. The spots for higher differences in NO formation compared to the reference case are shifted downstream at higher HFs. The effect of hydrogen enrichment on CO2 and H2O as radiation sources, as well as the volumetric absorption radiation of the furnace wall and the heat flux at furnace surfaces, has all been presented in relation to the effect of hydrogen addition on boiler performance.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Metrological support to gas-fired boiler plant
    Kashcheev, SA
    MEASUREMENT TECHNIQUES, 1999, 42 (05) : 509 - 511
  • [22] Efficiency and emissions of gas-fired industrial boiler fueled with hydrogen-enriched nature gas: A case study of 108 t/h steam boiler
    Wang, Tiantian
    Zhang, Hai
    Zhang, Yang
    Wang, Hongjian
    Lyu, Junfu
    Yue, Guangxi
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (65) : 28188 - 28203
  • [23] Application of the gas-fired boiler for household heating
    Zhang, J.G.
    Yang, W.S.
    Shi, Z.Q.
    Nuantong Kongtiao/HV & AC, 2001, 31 (04):
  • [24] Numerical and experimental investigation of surface-stabilized combustion in a gas-fired condensing boiler
    Erne, Sandro
    Scheger, Georg
    Wiedemair, Wolfgang
    RESULTS IN ENGINEERING, 2023, 17
  • [25] Predict NOx from gas-fired furnaces
    Kunz, RG
    Smith, DD
    Adamo, EM
    HYDROCARBON PROCESSING, 1996, 75 (11): : 65 - &
  • [26] Numerical simulation study on the combustion and emission characteristics of a gas-fired boiler using hydrogen-ammonia binary fuel
    Tao, Chengfei
    Wang, Yichen
    Sun, Zhouyifan
    Sun, Rongyue
    Zhou, Hao
    Duan, Lunbo
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 59
  • [27] Observations of Methane Emissions from Natural Gas-Fired Power Plants
    Hajny, Kristian D.
    Salmon, Olivia E.
    Rudek, Joseph
    Lyon, David R.
    Stuff, Andrew A.
    Stirm, Brian H.
    Kaeser, Robert
    Floerchinger, Cody R.
    Conley, Stephen
    Smith, Mackenzie L.
    Shepson, Paul B.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2019, 53 (15) : 8976 - 8984
  • [28] On the variability of air pollutant emissions from gas-fired industrial combustion plants
    Pulles, T
    Heslinga, D
    ATMOSPHERIC ENVIRONMENT, 2004, 38 (23) : 3827 - 3838
  • [29] Heat Recovery of Exhaust Flue Gas in Gas-fired Boiler
    Liu, He-jia
    Yang, Li
    Lu, Ming-tao
    2015 4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2015), 2015, : 2837 - 2841
  • [30] INCREASE OF OIL-FIRED OR GAS-FIRED BLOCK BOILER EFFICIENCY
    MILOBAR, Z
    STROJARSTVO, 1985, 27 (04): : 213 - 220