Measurement and analysis of partial discharge under high voltage continuous impulses for inverter-fed insulation

被引:0
|
作者
Tong, Laisheng [1 ]
Liu, Xi [1 ]
Wu, Guangning [1 ]
Lin, Tongguang [1 ]
Zhang, Guoqin [1 ]
机构
[1] Southwest Jiaotong University, Chengdu 610031, China
关键词
Electric insulation - Electric potential - Sensors - Traction motors;
D O I
暂无
中图分类号
学科分类号
摘要
Partial discharge (PD) is one of the key factors in insulation failure of inverter-fed traction motor. Due to the high steepness of impulse with broad frequency range, PD under continuous impulses is not easy to be detected by a conventional PD detection system. Impulse current sensor (ICS) has been applied to develop a new PD detection system and the wavelet packet method is used to extract the PD signals. Moreover, the coil of traction motor is used as the test sample. The statistics of test results of PD signals show that PD signals can be successfully identified by the new PD detection system. Finally, issues about the influence of voltage and frequency of square wave pulses on discharge number, maximum discharge and mean amplitude of PD signals are discussed.
引用
收藏
页码:61 / 64
相关论文
共 50 条
  • [41] The impact of test voltage waveform in determining the repetitive partial discharge inception voltage of Type I turn/turn insulation used in inverter-fed induction motors
    Lusuardi, Luca
    Cavallini, Andrea
    Caprara, Andrea
    Bardelli, Fabrizio
    Cattazzo, Andrea
    2018 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2018, : 478 - 481
  • [42] Effect of High Voltage Impulses on Partial Discharge Activity in a Cavity Embedded in Paper Insulation
    Kiiza, R. Clemence
    Nikjoo, R.
    Niasar, M. Ghaffarian
    Wang, X.
    Edin, H.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 133 - 136
  • [43] Ageing Analysis of Hairpin Windings in Inverter-Fed Motor Under PWM Voltage
    He, Chuxuan
    Tenbohlen, Stefan
    Beltle, Michael
    ENERGIES, 2025, 18 (06)
  • [44] Simplified measurement method for partial discharge inception voltage under repetitive impulses
    Kadowaki, Kazunori
    Takemura, Yujiro
    Nishimoto, Sakae
    IEEJ Transactions on Fundamentals and Materials, 2012, 132 (09): : 811 - 812
  • [45] Analysis of insulation characteristics of PWM inverter-fed induction motors
    Hwang, DH
    Park, DY
    Kim, YJ
    Kim, DH
    Koo, JY
    Hur, IG
    ISIE 2001: IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS PROCEEDINGS, VOLS I-III, 2001, : 477 - 481
  • [46] Partial discharge characteristics of nanocomposite enameled wire for inverter-fed motor
    Inuzuka, K.
    Inano, H.
    Hayakawa, N.
    Hirose, T.
    Hamaguchi, M.
    Okubo, H.
    2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 594 - 597
  • [47] FEASIBILITY OF PARTIAL DISCHARGE DETECTION IN INVERTER-FED ACTUATORS USED IN AIRCRAFTS
    Cavallini, A.
    Versari, L.
    Fornasari, L.
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 1250 - 1253
  • [48] A Novel Embedded Sensor for Partial Discharge Detection in Inverter-Fed Machines
    Ogundiran, Yinka Leo
    Griffo, Antonio
    Sundeep, Shubham
    Wang, Jiabin
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (04) : 4698 - 4707
  • [49] The Effect of Impulsive Voltage Rise Time on Insulation Endurance of Inverter-fed Motors
    Wang, Peng
    Cavallini, Andrea
    Montanari, Gian Carlo
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 84 - 87
  • [50] Characteristic Research on the Sensor for Inter-turn Partial Discharge Measurement of Inverter-fed Motor Winding
    Yuan, Pengfei
    Liu, Xuezhong
    Zhang, Tianlong
    Liu, Ping
    2019 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2019, : 13 - 17