A practical study of the 66-kV fault current limiter (FCL) system with rectifier

被引:0
|
作者
Tokuda, Noriaki [1 ]
Matsubara, Yoshio [1 ]
Yuguchi, Kyosuke [1 ]
Ohkuma, Takeshi [2 ]
Hobara, Natsuro [2 ]
Takahashi, Yoshihisa [2 ]
机构
[1] Nissin Electric Co., Ltd., Japan
[2] Tokyo Electric Power Co., Japan
来源
Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi) | 2007年 / 160卷 / 03期
关键词
Electric circuit breakers - Electric fault currents - Electric lines - Electric power distribution - Electric rectifiers - Superconducting cables;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
页码:12 / 18
相关论文
共 50 条
  • [21] Sub-cooled nitrogen cryostat for 66 kV/750A superconducting fault current limiter magnet
    Ohtani, Y
    Yazawa, T
    Kuriyama, T
    Nomura, S
    Ohkuma, T
    Hobara, N
    Takahashi, Y
    Inoue, K
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS. 49A AND B, 2004, 710 : 867 - 874
  • [22] Current Limiting Simulation of Magneto-biased Superconducting Fault Current Limiter (SFCL)Applied in 66 kV/10 kV Power Substation in China
    Wang, Qingshan
    Zhu, Jiahui
    Liu, Jialiang
    Liu, Yitao
    Wei, Defu
    Zheng, Nan
    Chen, Panpan
    Zhang, Hongjie
    Ding, Kaizhong
    Ertekin, Ercan
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2023, 33 (05)
  • [23] The research of a rectifier type high temperature superconducting fault current limiter
    Zhu, Q
    Zhou, YQ
    Hu, J
    ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, 2001, : 656 - 659
  • [24] Fault Current Limit (FCL) Technology (Magnetic Valve Controlled Reactor-Type Fault Current Limiter Principle and Simulation)
    Shi, Chunzhe
    KNOWLEDGE DISCOVERY AND DATA MINING, 2012, 135 : 135 - 141
  • [25] Cryogenic cooling system for a 154 kV/2 kA superconducting fault current limiter
    In, Sehwan
    Hong, Yong-Ju
    Yeom, Hankil
    Kim, Hyobong
    Park, Seong-Je
    Han, Young-Hee
    PROGRESS IN SUPERCONDUCTIVITY AND CRYOGENICS, 2018, 20 (02): : 34 - 39
  • [26] Single DC reactor type fault current limiter for 6.6 kV power system
    Nomura, T
    Yamaguchi, M
    Fukui, S
    Yokoyama, K
    Satoh, T
    Usui, K
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 2090 - 2093
  • [27] Study situation of applications of fault current limiter in power system
    Liu, Kai
    Chen, Hong-Kun
    Lin, Jun
    Huang, Juan
    He, Zhi-Qin
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (07): : 147 - 151
  • [28] Over-Current Characteristics of 66-kV RE123 HTS Power Cable
    Wang, Xudong
    Ishiyama, Atsushi
    Ohya, Masayoshi
    Fujiwara, Noboru
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 1013 - 1016
  • [29] Application of Fault Current Limiter in 22.9 kV KEPCO grid
    Kim, Min Jee
    Park, Kyungwon
    Ahn, Kil-Young
    Kim, Young-Geun
    Lim, Dong-Kyun
    2015 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2015, : 557 - 560
  • [30] FAULT SECTION DETECTION SYSTEM FOR 66-KV UNDERGROUND BRANCH TRANSMISSION-LINES USING OPTICAL MAGNETIC-FIELD SENSORS
    KATSUTA, G
    MURAOKA, K
    INOUE, N
    SAKAI, S
    TSUNEKAGE, T
    ANDO, K
    IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (01) : 1 - 9