Study on secondary arc current of UHV line using HSGS

被引:0
|
作者
Wu, Jian-Ling [1 ]
Zhang, Si [2 ,3 ]
Zhang, Yi [4 ]
Pan, Shao-Liang [5 ]
Pan, Hong-Wu [5 ]
Wu, Guo-Ying [5 ]
Zhou, Hao [3 ]
机构
[1] Zhejiang Electric Power Company, Hangzhou 310007, China
[2] Cixi Power Supply Bureau, Cixi 315300, China
[3] School of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
[4] Huzhou Electric Power Company, Huzhou 313000, China
[5] Huzhou Electric Power Design Institute, Huzhou 313000, China
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:52 / 55
相关论文
共 50 条
  • [41] An accurate compensation method of distributed capacitance current in differential protection of UHV transmission line
    Bi, TS
    Yu, YL
    Huang, SF
    Yang, QX
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 770 - 774
  • [42] Fault location technique using GA-ANFIS for UHV line
    Banu, G.
    Suja, S.
    ARCHIVES OF ELECTRICAL ENGINEERING, 2014, 63 (02) : 247 - 262
  • [43] Investigation of neutral reactor performance in reducing secondary arc current
    Zadeh, Mohammad Reza Dadash
    Sanaye-Pasand, Majid
    Kadivar, Ali
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 2472 - 2479
  • [44] Research on Suppression of Secondary Arc Current Based on Controllable Reactor
    Wang Miaomiao
    Yin Zhongdong
    Wang Zhijian
    Wang Ziqiang
    ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 2, PROCEEDINGS, 2009, : 240 - 243
  • [45] Measurement of arc current using NCIT
    Park, J. N.
    Lee, Y. H.
    Lee, H. W.
    Shin, Y. S.
    Lee, B. W.
    Kim, Y. G.
    Oh, I. S.
    Lim, K. J.
    Lee, J. S.
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 885 - 888
  • [46] Separation of Arc Plasma and Current in Electrical Arc - An Initial Study
    Chen, S. J.
    Jiang, F.
    Lu, Y. S.
    Zhang, Y. M.
    WELDING JOURNAL, 2014, 93 (07) : 253S - 261S
  • [47] A STUDY OF REPRODUCIBILITY OF THE DIRECT CURRENT ARC
    ROSENBERRY, LP
    ANALYTICAL CHEMISTRY, 1951, 23 (04) : 682 - 682
  • [48] Calculation of Induced Voltage and Current on a Crossing Transmission Line under UHV AC Transmission Lines
    Li Yuze
    Kong Xiaofeng
    Zhang Bo
    2019 IEEE ASIA POWER AND ENERGY ENGINEERING CONFERENCE (APEEC 2019), 2019, : 132 - 136
  • [49] Suppression measures for induced voltage and current of deicer of UHV double-circuit transmission line
    Yu, Zhanqing
    Guo, Zhichong
    Lu, Jiazheng
    Tan, Yanjun
    He, Jinliang
    Hu, Jun
    Gaodianya Jishu/High Voltage Engineering, 2014, 40 (05): : 1332 - 1338
  • [50] Secondary arc current of ultra-high voltage transmission line with a mixed voltage of 1000/500 kV on a single tower
    Sima, Wenxia
    Wang, Rong
    Yang, Ming
    Yang, Qing
    Yuan, Tao
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (07) : 686 - 693