USE OF TDR TECHNIQUE TO MEASURE GRAIN MOISTURE CONTENT

被引:1
|
作者
Majcher, Jacek [1 ]
机构
[1] Lublin Univ Technol, Dept Elect Engn & Smart Technol, Nadbystrzycka 38A, PL-20618 Lublin, Poland
关键词
TDR probe; grain; moisture; measurements; TIME-DOMAIN REFLECTOMETRY; WATER-CONTENT; QUALITY;
D O I
10.24425/mms.2024.150288
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Time Domain Reflectometry (TDR) technique is widely employed across various industrial sectors due to its high speed and measurement selectivity. It is mainly used for measuring soil moisture or electrical conductivity. In this paper, the possibility of using this technique to measure moisture content of various seeds is analyzed. For this purpose, a commercial TDR meter - FOM2/mts with FP/mts - field TDR probe was used to measure dielectric permittivity for different seed species. The obtained results were then correlated with seed moisture content and calibration curves were proposed for each seed species. In addition, the effect of temperature on the dielectric permittivity readout was studied and a correction factor was proposed.
引用
收藏
页码:565 / 576
页数:12
相关论文
共 50 条
  • [31] RF Sensing of Grain and Seed Moisture Content
    Nelson, Stuart O.
    Trabelsi, Samir
    Kraszewski, Andrzej W.
    IEEE SENSORS JOURNAL, 2001, 1 (02) : 119 - 126
  • [32] EQUILIBRIUM MOISTURE-CONTENT OF GRAIN DUSTS
    LAI, FS
    MILLER, BS
    POMERANZ, Y
    CEREAL FOODS WORLD, 1979, 24 (09) : 457 - 457
  • [33] Dynamic equilibrium moisture content for grain drying
    Chen, C
    Jayas, DS
    CANADIAN AGRICULTURAL ENGINEERING, 1998, 40 (04): : 299 - 303
  • [34] DEVELOPMENT AND EVALUATION OF A LOW-COST PROBE-TYPE INSTRUMENT TO MEASURE THE EQUILIBRIUM MOISTURE CONTENT OF GRAIN
    Armstrong, P. R.
    McNeil, S. G.
    Manu, N.
    Bosomtwe, A.
    Danso, J. K.
    Osekre, E.
    Opit, G.
    APPLIED ENGINEERING IN AGRICULTURE, 2017, 33 (05) : 619 - 627
  • [35] Determination of moisture content in a deformable soil using time-domain reflectometry (TDR)
    Kim, DJ
    Choi, SI
    Ryszard, O
    Feyen, J
    Kim, HS
    EUROPEAN JOURNAL OF SOIL SCIENCE, 2000, 51 (01) : 119 - 127
  • [36] Suitability of time domain reflectometry (TDR) for moisture content monitoring in historic building walls
    Freitas, Teresa Stingl
    Guimaraes, Ana Sofia
    de Freitas, Vasco Peixoto
    4TH CENTRAL EUROPEAN SYMPOSIUM ON BUILDING PHYSICS (CESBP 2019), 2019, 282
  • [37] USE OF INTERNAL-FRICTION TECHNIQUE TO MEASURE RATES OF GRAIN-BOUNDARY SLIDING
    MOSHER, DR
    RAJ, R
    ACTA METALLURGICA, 1974, 22 (12): : 1469 - 1474
  • [38] GRAIN MOISTURE-CONTENT DETERMINATION BY MICROWAVE MEASUREMENTS
    NELSON, SO
    KRASZEWSKI, AW
    TRANSACTIONS OF THE ASAE, 1990, 33 (04): : 1303 - 1307
  • [39] Calibration of a microwave system for measuring grain moisture content
    Ben Slima, M
    Morawski, RZ
    Kraszewski, AW
    Barwicz, A
    Nelson, SO
    WHERE INSTRUMENTATION IS GOING - CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 1998, : 642 - 647
  • [40] Using cereal grain permittivity for sensing moisture content
    Nelson, SO
    Kraszewski, AW
    Trabelsi, S
    Lawrence, KC
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (03) : 470 - 475