Pressure measurement in SF6 circuit breaker's nozzle in heavy current interruption

被引:0
|
作者
Liu, Wei-Dong [1 ]
Wu, Jun-Yong [2 ]
Huang, Yu-Long [1 ]
Wu, Jun-Hui [2 ]
Guan, Yong-Gang [1 ]
Zhang, Hua [2 ]
Tian, Gang-Ling [2 ]
机构
[1] State Key Lab. of Control and Simulation of Power Systems and Generation Equipments, Dept. of Electrical Engineering, Tsinghua University, Haidian District, Beijing 100084, China
[2] Henan Pinggao Electric Co., Ltd., Pingdingshan 467001, Henan Province, China
关键词
D O I
暂无
中图分类号
学科分类号
摘要
15
引用
收藏
页码:131 / 136
相关论文
共 50 条
  • [21] Influence of Arc Energy to Puffer Pressure Rise for SF6 Circuit Breaker
    Lin Xin
    Liu Ke-bin
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 512 - 515
  • [22] Simulation and Analysis of Small Capacitive Current Interruption of a 550kV Single-break SF6 Circuit Breaker
    Hao, Xiangyu
    Guo, Yujing
    Yao, Yongqi
    Wang, Zhijun
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [23] Online Condition Monitoring of SF6 Circuit Breaker
    Mallikar-Godbole, Lubdha
    Kushare, B. E.
    PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS AND CONTROL (ISCO'16), 2016,
  • [24] SF6 CIRCUIT-BREAKER DESIGN AND PERFORMANCE
    STEWART, JS
    ELECTRONICS AND POWER, 1979, 25 (02): : 121 - 126
  • [25] Instability of DC arc in SF6 circuit breaker
    Ito, H
    Hamano, S
    Ibuki, K
    Yoshinaga, K
    Hasegawa, T
    Yamaji, K
    Irokawa, H
    IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (04) : 1508 - 1513
  • [26] Circuit Breaker Prognostics Using SF6 Data
    Rudd, S. E.
    Catterson, V. M.
    McArthur, S. D. J.
    Johnstone, C.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [27] Interruption Features in SF6 Circuit Breaker Based on Real Gas Redlich-Kwong Equation
    Lin X.
    Su A.
    Li X.
    Xia Y.
    Wang F.
    Gaodianya Jishu/High Voltage Engineering, 2018, 44 (03): : 704 - 710
  • [28] Interruption Characteristics of High-voltage Hybrid Circuit Breaker Based on the Alternative of SF6 Gas
    Cheng X.
    Chen Z.
    Ge G.
    Jiao L.
    Liao M.
    Gaodianya Jishu, 12 (3862-3868): : 3862 - 3868
  • [29] SF6 PUFFER CIRCUIT BREAKER: SCHLIEREN VISUALISATION OF HOT CIRCULATION FOLLOWING FAULT INTERRUPTION.
    Stokes, A.D.
    Manganaro, S.
    Giglio, M.
    Colombo, E.
    Energia Elettrica, 1984, 61 (06): : 275 - 280
  • [30] Pressure Measurement and Characteristic Analysis on a 252-kV Puffer-Type SF6 Circuit Breaker
    Guan, Yonggang
    Liu, Weidong
    Wu, Junhui
    Wu, Junyong
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (04) : 2616 - 2622