A computational workflow for modeling complex patient-specific coronary stenting cases

被引:0
|
作者
Antonini, Luca [1 ,2 ]
Poletti, Gianluca [1 ]
Karanasiou, Georgia S. [3 ,4 ]
Sakellarios, Antonis [3 ,4 ]
Fotiadis, Dimitrios I. [3 ,4 ]
Petrini, Lorenza [5 ]
Pennati, Giancarlo [1 ]
Berti, Francesca [1 ]
机构
[1] Politecn Milan, Lab Biol Struct Mech LaBS, Dept Chem Mat & Chem Engn Giulio Natta, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
[2] Parametr Design Suisse Sagl, Chiasso, CH, Switzerland
[3] Dept Biomed Res Inst FORTH, Univ Campus Ioannina, Ioannina 45110, Greece
[4] Univ Hosp Ioannina, Dept Cardiol 2, Ioannina 45110, Greece
[5] Politecn Milan, Dept Civil & Environm Engn, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
关键词
Finite element analysis; Overstretching; Arterial softening; OCT; In silico trial; LEVEL COLLAGEN DAMAGE; MECHANICAL-PROPERTIES; BIFURCATIONS;
D O I
10.1016/j.cmpb.2024.108527
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objectives: In the era of in silico clinical trials, it is of paramount importance to guarantee simulation reliability. In the field of coronary stenting, there is a need to couple validated stent models with credible digital twins of the arteries, whose mechanical behavior is commonly simplified to guarantee a balance between simulation complexity and computational time, namely usability. To this aim, the current work proposed a phenomenological approach suitable for the mechanical description of patient-specific coronary arteries undergoing coronary stenting in complex cases, e.g. bifurcations, exhibiting overstretching due to procedural choices. Methods: Pre- and post-operative images were used to prepare four vessel models and validate the outcome of multi-step structural stenting simulations in terms of recovered lumen area. Arteries were modeled improving a previous strategy by the authors, namely accounting for different mechanical properties in the media and adventitia layer, with an assigned hyperelastic response with a softening at higher strains to simulate the damage due to overstretching. Plaque components, which were identified from patient images, were classified into lipidic, calcified, and generic, and associated with different properties. Results: The simulation results demonstrated a good match with the clinical outcome of all the stenting procedures, with errors lower than 15 % in terms of recovered lumen area. This proved the reliability of the proposed simulation framework improving the performances of the previous model, making it usable for interpreting also situations where the artery underwent overstretching. Conclusions: The proposed approach allowed to account for the in vivo conditions and have good performance when aiming at describing quantities such as lumen reopening and the presence of malapposed struts following stent deployment.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Patient-Specific Modeling of Blood Flow and Pressure in Human Coronary Arteries
    Kim, H. J.
    Vignon-Clementel, I. E.
    Coogan, J. S.
    Figueroa, C. A.
    Jansen, K. E.
    Taylor, C. A.
    ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (10) : 3195 - 3209
  • [42] Patient-Specific Modeling of Blood Flow and Pressure in Human Coronary Arteries
    H. J. Kim
    I. E. Vignon-Clementel
    J. S. Coogan
    C. A. Figueroa
    K. E. Jansen
    C. A. Taylor
    Annals of Biomedical Engineering, 2010, 38 : 3195 - 3209
  • [43] A Computational Modeling and Simulation Workflow to Investigate the Impact of Patient-Specific and Device Factors on Hemodynamic Measurements from Non-Invasive Photoplethysmography
    Fine, Jesse
    McShane, Michael J.
    Cote, Gerard L.
    Scully, Christopher G.
    BIOSENSORS-BASEL, 2022, 12 (08):
  • [44] Patient-specific finite element analysis of popliteal stenting
    Conti, Michele
    Marconi, Michele
    Campanile, Giulia
    Reali, Alessandro
    Adami, Daniele
    Berchiolli, Raffaella
    Auricchio, Ferdinando
    MECCANICA, 2017, 52 (03) : 633 - 644
  • [45] Patient-specific finite element analysis of popliteal stenting
    Michele Conti
    Michele Marconi
    Giulia Campanile
    Alessandro Reali
    Daniele Adami
    Raffaella Berchiolli
    Ferdinando Auricchio
    Meccanica, 2017, 52 : 633 - 644
  • [46] Coupling of EIT with computational lung modeling for predicting patient-specific ventilatory responses
    Roth, Christian J.
    Becher, Tobias
    Frerichs, Inez
    Weiler, Norbert
    Wall, Wolfgang A.
    JOURNAL OF APPLIED PHYSIOLOGY, 2017, 122 (04) : 855 - 867
  • [47] Advancements and Opportunities in Characterizing Patient-Specific Wall Shear Stress Imposed by Coronary Artery Stenting
    LaDisa, John F., Jr.
    Ghorbannia, Arash
    Marks, David S.
    Mason, Peter
    Otake, Hiromasa
    FLUIDS, 2022, 7 (10)
  • [48] Software for optimized virtual stenting of patient-specific coronary arteries reconstructed from angiography images
    Djukic, Tijana
    Tomasevic, Smiljana
    Saveljic, Igor
    Vukicevic, Arso
    Stankovic, Goran
    Filipovic, Nenad
    Computers in Biology and Medicine, 2024, 183
  • [49] A PATIENT-SPECIFIC CORONARY DENSITY ESTIMATE
    Shahzad, R.
    Schaap, M.
    van Walsum, T.
    Klien, S.
    Weustink, A. C.
    van Vliet, L. J.
    Niessen, W. J.
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 9 - 12
  • [50] Computational modeling of vascular growth in patient-specific pulmonary arterial patch reconstructions
    Lashkarinia, S. Samaneh
    Coban, Gursan
    Kose, Banu
    Salihoglu, Ece
    Pekkan, Kerem
    JOURNAL OF BIOMECHANICS, 2021, 117