Liver Fat Quantification With Ultrasound: Depth Dependence of Attenuation Coefficient

被引:2
|
作者
Ferraioli G. [1 ]
Raimondi A. [1 ,2 ]
Maiocchi L. [2 ]
De Silvestri A. [3 ]
Poma G. [2 ]
Kumar V. [4 ]
Barr R.G. [5 ]
机构
[1] Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Pavia
[2] Ultrasound Unit, Fondazione IRCCS Policlinico S. Matteo, Pavia
[3] Clinical Epidemiology and Biometric Unit, Fondazione IRCCS Policlinico S. Matteo, Pavia
[4] Center for Ultrasound Research & Translation, Department of Radiology, Massachusetts General Hospital, Boston, MA
[5] Department of Radiology, Northeastern Ohio Medical University, Rootstown
[6] Southwoods Imaging, Youngstown, OH
关键词
ATI; attenuation coefficient; fat quantification; liver steatosis; NAFLD; ROI depth; ROI size; UDFF;
D O I
10.1002/jum.16242
中图分类号
学科分类号
摘要
Objectives: The primary aim was to estimate the influence of various depths on ultrasound attenuation coefficient (AC) of multiple vendors in the liver. The secondary aim was to evaluate the impact of region of interest (ROI) size on AC measurements in a subset of participants. Methods: This Institutional Review Board (IRB)-approved Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study was carried out in two centers using AC-Canon and AC-Philips algorithms and extracting AC-Siemens values from ultrasound-derived fat fraction algorithm. Measurements were performed positioning ROI upper edge (3 cm size) at 2, 3, 4, 5 cm from the liver capsule with AC-Canon and AC-Philips and at 1.5, 2, 3 cm with Siemens algorithm. In a subset of participants, measurements were obtained with 1 and 3 cm ROI size. Univariate and multivariate linear regression models and Lin's concordance correlation coefficient (CCC) were used for statistical analysis as appropriate. Results: Three different cohorts were studied. Sixty-three participants (34 females; mean age: 51 ± 14 years) were studied with AC-Canon, 60 (46 females; mean age: 57 ± 11 years) with AC-Philips, and 50 (25 females; 61 ± 13 years) with AC-Siemens. There was a decrease in AC values per 1 cm increase in depth in all. In multivariable analysis, the coefficient was −0.049 (−0.060; −0.038 P <.001) with AC-Canon, −0.058 (−0.066; −0.049 P <.001) with AC-Philips and −0.081 (−0.112; −0.050 P <.001) with AC-Siemens. AC values with 1 cm ROI were significantly higher than those obtained with 3 cm ROI at all depths (P <.001) but the agreement between AC values obtained with different ROI size was excellent (CCC 0.82 [0.77–0.88]). Conclusions: There is depth dependence in AC measurement that affects results. A standardized protocol with fixed ROI's depth and size is needed. © 2023 The Authors. Journal of Ultrasound in Medicine published by Wiley Periodicals LLC on behalf of American Institute of Ultrasound in Medicine.
引用
收藏
页码:2247 / 2255
页数:8
相关论文
共 50 条
  • [31] ACOUSTIC DETECTION OF DIFFUSELY DISEASED LIVER BY FREQUENCY-DEPENDENCE OF ULTRASOUND ATTENUATION
    LIN, T
    OPHIR, J
    POTTER, GD
    GASTROENTEROLOGY, 1987, 92 (05) : 1751 - 1751
  • [32] CLINICAL-APPLICATION OF AN ULTRASOUND ATTENUATION COEFFICIENT ESTIMATION TECHNIQUE FOR LIVER PATHOLOGY CHARACTERIZATION
    KUC, R
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (06) : 312 - 319
  • [33] Quantification of hepatic steatosis with ultrasound: promising role of attenuation imaging coefficient in a biopsy-proven cohort
    Burgio, Marco Dioguardi
    Ronot, Maxime
    Reizine, Edouard
    Rautou, Pierre-Emmanuel
    Castera, Laurent
    Paradis, Valerie
    Garteiser, Philippe
    Van Beers, Bernard
    Vilgrain, Valerie
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 2293 - 2301
  • [34] Quantification of hepatic steatosis with ultrasound: promising role of attenuation imaging coefficient in a biopsy-proven cohort
    Marco Dioguardi Burgio
    Maxime Ronot
    Edouard Reizine
    Pierre-Emmanuel Rautou
    Laurent Castera
    Valérie Paradis
    Philippe Garteiser
    Bernard Van Beers
    Valérie Vilgrain
    European Radiology, 2020, 30 : 2293 - 2301
  • [35] Ultrasound-Based Attenuation Imaging for the Non-Invasive Quantification of Liver Fat - A Pilot Study on Feasibility and Inter-Observer Variability
    Jesper, Daniel
    Klett, Daniel
    Schellhaas, Barbara
    Pfeifer, Lukas
    Leppkes, Moritz
    Waldner, Maximilian
    Neurath, Markus F.
    Strobel, Deike
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2020, 8
  • [36] Ultrasound hepatic/renal ratio and hepatic attenuation rate for quantifying liver fat content
    Bo Zhang
    Fang Ding
    Tian Chen
    Liang-Hua Xia
    Juan Qian
    Guo-Yi Lv
    World Journal of Gastroenterology, 2014, (47) : 17985 - 17992
  • [37] Ultrasound hepatic/renal ratio and hepatic attenuation rate for quantifying liver fat content
    Zhang, Bo
    Ding, Fang
    Chen, Tian
    Xia, Liang-Hua
    Qian, Juan
    Lv, Guo-Yi
    WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (47) : 17985 - 17992
  • [38] DEPENDENCE OF ULTRASONIC-ATTENUATION OF LIVER ON PATHOLOGICAL FAT AND FIBROSIS - EXAMINATION WITH EXPERIMENTAL FATTY LIVER AND LIVER FIBROSIS MODELS
    SUZUKI, K
    HAYASHI, N
    SASAKI, Y
    KONO, M
    KASAHARA, A
    FUSAMOTO, H
    IMAI, Y
    KAMADA, T
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1992, 18 (08): : 657 - 666
  • [39] The diagnostic performance of attenuation coefficient computed on the ultrasound image compared to a biochemical marker - SteatoTest - for steatosis quantification in non-alcoholic fatty liver disease
    Radu, C.
    Grigorescu, M.
    Lupsor, M.
    Vicas, C.
    Nedevschi, S.
    Badea, R.
    Grigorescu, M. D.
    Sparchez, Z.
    Crisan, D.
    Feier, D.
    PROCEEDINGS OF 2010 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS (AQTR 2010), VOLS. 1-3, 2010,
  • [40] Relation between the diffuse attenuation coefficient and the Secchi depth
    V. I. Mankovsky
    Oceanology, 2014, 54 : 32 - 37