A 9-year study of the degradation of a HDPE geomembrane liner used in different high pH mining applications

被引:1
|
作者
e Silva, Rodrigo A. [1 ]
Abdelaal, Fady B. [1 ]
Rowe, R. Kerry [2 ]
机构
[1] Queens Univ, Geoengn Ctr Queens RMC, Ellis Hall, Kingston, ON K7L 3N6, Canada
[2] Queens Univ, Geoengn Ctr Queens RMC, Geotech & Geoenvironm Engn, Ellis Hall, Kingston, ON K7L 3N6, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
Geosynthetics; Geomembrane; Mining; Heap leaching; Degradation; Nominal failure; Arrhenius; LONG-TERM PERFORMANCE; STRESS CRACK RESISTANCE; ACIDIC MINE DRAINAGE; ANTIOXIDANT DEPLETION; HIGH-TEMPERATURES; POLYETHYLENE; GOLD; LEACHATE; EXPOSURE; BEHAVIOR;
D O I
10.1016/j.geotexmem.2024.09.012
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The degradation of a HDPE geomembrane in heap leaching environments is evaluated using immersion tests at five temperatures. The incubation solutions had a pH of 9.5, 11.5, and 13.5, relevant to gold and silver pregnant liquor solutions. After 9.3 years, the geomembrane's mechanical properties had reached nominal failure at 95, 85, and 75 degrees C in all three solutions. It is shown that the pH 13.5 solution had the greatest effect on the antioxidant depletion (Stage I) and polymer degradation (Stage III), but was the least aggressive to initiate the degradation (Stage II) compared to the pH 11.5 and 9.5 solutions. Overall, the time to nominal failure (time to 50% of the initial or specified property value) in pH 13.5 was slightly shorter than the pH 9.5 and 11.5 solutions. Based purely on immsersion tests, the time to nominal failure of this specific geeomembrane at 30oC is predicted to be 150 years in the pH 9.5 and 11.5 solutions, and 140 years in the pH 13.5 solution. Assuming a good liner design that limits the tensile strains in the GMB, nominal failure in a composite liner configuration is predicted to exceed 260 years at 30 degrees C and the expected value could exceed 1000 years at 10 degrees C.
引用
收藏
页码:230 / 246
页数:17
相关论文
共 26 条
  • [21] A 9-YEAR FOLLOW-UP-STUDY OF THE IMMUNOGENICITY AND LONG-TERM EFFICACY OF PLASMA-DERIVED HEPATITIS-B VACCINE IN HIGH-RISK CHINESE NEONATES
    DING, LM
    ZHANG, MT
    WANG, YF
    ZHOU, SC
    KONG, WQ
    SMEGO, RA
    CLINICAL INFECTIOUS DISEASES, 1993, 17 (03) : 475 - 479
  • [22] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF MORPHINE AND THE MAIN DEGRADATION PRODUCT PSEUDO-MORPHINE - A STUDY OF PH, DISCOLORATION AND DEGRADATION IN 1-YEAR-OLD TO 43-YEAR-OLD MORPHINE INJECTIONS
    ROKSVAAG, PO
    FREDRIKSON, JB
    WAALER, T
    PHARMACEUTICA ACTA HELVETIAE, 1980, 55 (7-8): : 198 - 202
  • [23] Study on solar absorptance and thermal stability of solid particles materials used as TES at high temperature on different aging stages for CSP applications
    Palacios, Anabel
    Calderon, Alejandro
    Barreneche, Camila
    Bertomeu, Joan
    Segarra, Merce
    Ines Fernandez, A.
    SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2019, 201
  • [24] All-terrain vehicle (ATV)-related injuries among different age groups: insights from a 9-year observational study (May, 10.1007/s00068-022-01984-1, 2022)
    Abdelrahman, Husham
    Khan, Naushad Ahmad
    El-Menyar, Ayman
    Consunji, Rafael
    Asim, Mohammad
    Alani, Mushrek
    Shunni, Adam
    Al-Aieb, Abubaker
    Al-Thani, Hassan
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (06) : 4983 - 4983
  • [25] Impact of the human papillomavirus status on the development of high-grade cervical intraepithelial neoplasia in women negative for intraepithelial lesions or malignancy at the baseline: A 9-year Swedish nested case-control follow-up study
    Froberg, Maria
    Ostensson, Ellinor
    Belkic, Karen
    Ostrbenk, Anja
    Poljak, Mario
    Mints, Miriam
    Arbyn, Marc
    Andersson, Sonia
    CANCER, 2019, 125 (02) : 239 - 248
  • [26] Corrosion behavior of erbium chromium-doped yattrium-scandium-gallium-garnet (Er,Cr:YSGG 2780 nm) laser-treated titanium alloy used for dental applications at different pH conditions (in vitro study)
    Abd El daym D.A.
    Gheith M.E.
    Abbas N.A.
    Rashed L.A.
    Abd El Aziz Z.A.
    Lasers in Dental Science, 2018, 2 (3) : 137 - 146