Precise alignment of separated Sagnac interferometer

被引:0
|
作者
Zhang, Xuemin [1 ,2 ]
Wei, Ruyi [1 ,2 ]
Yan, Su [1 ]
Duan, Jiayou [1 ]
Li, Hua [1 ]
Yang, Jianfeng [1 ]
机构
[1] Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an, Shaanxi 710119, China
[2] University of Chinese Academy of Sciences, Beijing 100049, China
来源
关键词
Reflection - Alignment - Fiber optic sensors - Interferometers;
D O I
10.3788/CJL201340.0416001
中图分类号
学科分类号
摘要
A separated Sagnac interferometer with optical diameter of 60 mm and spectral channel of 65 is introduced based on its working principle. Ideal interference fringes and interference fringes are simulated when reflector has an angle deviation, and the effect of alignment error to the interference fringes is analyzed. The position accuracy and angle accuracy of alignment are induced based on the optical design parameters. The method of precision alignment is introduced in detail, which includes the installation of primary alignment plane, the precise location of splitting prism, the precise adjustment of long-arm and short-arm reflectors. Through the installation of alignment refrence and the masterly refrence transformation, the precise alignment of separated Sagnac interferometer is achieved based on the principle of auto-collimation, whose position accuracy is better than 0.01 mm, angle accuracy is better than 1″, super possition accuracy of primary working plane is better than 1″.
引用
收藏
相关论文
共 50 条
  • [1] Automatic precise alignment of Sagnac interferometer
    Li Tian-yue
    Zhang Xue-min
    Song Xing
    FOURTH SEMINAR ON NOVEL OPTOELECTRONIC DETECTION TECHNOLOGY AND APPLICATION, 2018, 10697
  • [2] Alignment of a birefringent fiber Sagnac interferometer by fiber twist
    Kuzin, EA
    Núñez, HC
    Korneev, N
    OPTICS COMMUNICATIONS, 1999, 160 (1-3) : 37 - 41
  • [3] SAGNAC INTERFEROMETER
    BABCOCK, GC
    AMERICAN JOURNAL OF PHYSICS, 1962, 30 (04) : 311 - &
  • [4] Self-alignment of a compact large-area atomic Sagnac interferometer
    Tackmann, G.
    Berg, P.
    Schubert, C.
    Abend, S.
    Gilowski, M.
    Ertmer, W.
    Rasel, E. M.
    NEW JOURNAL OF PHYSICS, 2012, 14
  • [5] POLARIZATION SAGNAC INTERFEROMETER
    GITELSON, S
    NEWBURGH, RG
    SAKAI, H
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1972, 62 (11) : 1376 - 1376
  • [6] Phase shifting holographic interferometer for precise alignment measurements in packaging applications
    Nikulin, Vladimir V.
    Khandekar, Rahul
    Bedi, Vijit
    PRACTICAL HOLOGRAPHY XXV: MATERIALS AND APPLICATIONS, 2011, 7957
  • [7] A precise measurement method for linewidth enhancement factor of SOA by Sagnac interferometer when considering XGM
    Li, Yajie
    Wu, Chongqing
    Shum, P.
    Fu, Songnian
    Wei, Bin
    PASSIVE COMPONENTS AND FIBER-BASED DEVICES III, PTS 1 AND 2, 2006, 6351
  • [8] Pentaferometer: a solid Sagnac interferometer
    Hirschberg, JG
    Kohen, E
    APPLIED OPTICS, 1999, 38 (01) : 136 - 138
  • [9] Cold atom sagnac interferometer
    Wendrich, T.
    Gilowski, M.
    Mueller, T.
    Herr, W.
    Schubert, C.
    Rasel, E. M.
    Ertmer, W.
    PROCEEDINGS OF THE 2007 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM-JOINTLY WITH THE 21ST EUROPEAN FREQUENCY AND TIME FORUM, VOLS 1-4, 2007, : 647 - 647
  • [10] Spectrally selective Sagnac interferometer
    Monzon, D
    Starodumov, AN
    Zenteno, LA
    Goitia, ABY
    de la Rosa, E
    REVISTA MEXICANA DE FISICA, 1997, 43 (06) : 972 - 980