Pulse-Echo Ultrasound for Quantitative Measurements of Two Uncorrelated Elastic Parameters

被引:1
|
作者
Hansen, Rune [1 ,2 ]
Ervik, Oyvind [2 ,3 ]
Amini, Naseh [4 ]
Solberg, Stian [4 ]
Berg, Sigrid [1 ]
Ayyalasomayajula, Venkat [5 ]
Skallerud, Bjorn [5 ]
Leira, Hakon Olav [2 ,6 ]
Sorger, Hanne [2 ,3 ]
Avdal, Jorgen [1 ]
机构
[1] SINTEF Digital, Dept Hlth Res, Postboks 4760 Torgarden, N-7465 Trondheim, Norway
[2] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, Trondheim, Norway
[3] Levanger Hosp, Nord Trondelag Hosp Trust, Clin Med, Levanger, Norway
[4] SURF Technol, Trondheim, Norway
[5] Norwegian Univ Sci & Technol, Dept Struct Engn, Trondheim, Norway
[6] St Olavs Hosp, Dept Thorac Med, Trondheim, Norway
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2025年 / 51卷 / 01期
关键词
Ultrasound; Elastic properties; Nonlinear acoustics; Dual-frequency; Shear waves; ACOUSTIC NONLINEARITY; SHEAR-WAVE; BIOMEDICAL FREQUENCIES; REFLECTION MODE; SOUND SPEED; TISSUE; ELASTOGRAPHY; CONTRAST; SINGLE; STRAIN;
D O I
10.1016/j.ultrasmedbio.2024.08.006
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective: This paper describes the relationship between elastic tissue properties and strain and presents an initial investigation of pulse-echo ultrasound to measure two uncorrelated elastic parameters in tissue-mimicking phantoms. The two elastic parameters are the shear modulus, related to deformation of shape, and what we in the paper define as the nonlinear compressibility, related to deformation of volume. Methods: We prepared tissue-mimicking phantoms containing lesions of variable shear modulus and variable nonlinear compressibility. An in-house framework for shear wave imaging was developed using ultrasound radiation force at 4.5 MHz to induce shear waves and plane wave imaging with pulses in a frequency band centered around 12.5 MHz to track the shear waves. For measurements of nonlinear compressibility, co-propagating dual-frequency pulse complexes at 0.7 MHz and 14 MHz were applied. Algorithms were implemented on a Verasonics Vantage ultrasound scanner and a custom-made multi-frequency ultrasound transducer was used. Mechanical indentation measurements were performed to validate ultrasound measurements of the shear modulus. For the nonlinear compressibility, ultrasound measurements were compared to results derived from the literature. Results: We found good agreement in elasticity results from ultrasound measurements and mechanical indentation as well as when comparing with results derived from the literature. Conclusion: Results of the current investigation were promising. We plan patient studies involving thyroid lesions and liver steatosis to explore whether measurements of elastic parameters related both to shape deformation and volume deformation are useful in clinical practice.
引用
收藏
页码:15 / 25
页数:11
相关论文
共 50 条
  • [41] A Bidirectional Front-End for Ultrasonic Pulse-Echo Measurements
    Marchetti, Luca
    Berg, Yngvar
    Azadmehr, Mehdi
    2018 IEEE 15TH INTERNATIONAL CONFERENCE ON NETWORKING, SENSING AND CONTROL (ICNSC), 2018,
  • [42] ELASTIC CONSTANTS OF SODIUM CHLORATE SINGLE CRYSTALS BY PULSE-ECHO METHOD
    VISWANATHAN, R
    JOURNAL OF APPLIED PHYSICS, 1966, 37 (02) : 884 - +
  • [43] Pulse-echo Ultrasound Identifies Caucasian and Hispanic Women at Risk for Osteoporosis
    Lewiecki, E. Michael
    JOURNAL OF CLINICAL DENSITOMETRY, 2020, 24 (02) : 175 - 182
  • [44] THE OUTPUT OF PULSE-ECHO ULTRASOUND EQUIPMENT - A SURVEY OF POWERS, PRESSURES AND INTENSITIES
    DUCK, FA
    STARRITT, HC
    AINDOW, JD
    PERKINS, MA
    HAWKINS, AJ
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (694): : 989 - 1001
  • [45] Wavelet restoration of medical pulse-echo ultrasound images in an EM framework
    Ng, James
    Prager, Richard
    Kingsbury, Nick
    Treece, Graham
    Gee, Andrew
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (03) : 550 - 568
  • [46] All-optical pulse-echo ultrasound probe for intravascular imaging
    Colchester, Richard J.
    Noimark, Sacha
    Mosse, Charles A.
    Zhang, Edward Z.
    Beard, Paul C.
    Parkin, Ivan P.
    Papakonstantinou, Ioannis
    Desjardins, Adrien E.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS XII, 2016, 9689
  • [47] ANALYSIS OF A PULSE-ECHO ULTRASOUND TAPERED PHASED-ARRAY TRANSDUCER
    BENKESER, PJ
    GOFF, EF
    RICE, WO
    ULTRASONICS, 1987, 25 (06) : 376 - 376
  • [48] SonicPy: a suite of programs for ultrasound pulse-echo data acquisition and analysis
    Hrubiak, Rostislav
    Sturtevant, Blake T. T.
    HIGH PRESSURE RESEARCH, 2023, 43 (01) : 23 - 39
  • [49] The Enhancement of Pulse-echo Ultrasound Signal Using Adaptive Filter with NLMS
    Li, Dongdong
    Wang, Hui
    Deng, Juan
    Zheng, Zheng
    Bu, Zhaohui
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1050 - 1053
  • [50] Use of Pulse-Echo Ultrasound Imaging in Transcranial Diagnostics of Brain Structures
    Sukhoruchkin D.A.
    Yuldashev P.V.
    Tsysar S.A.
    Khokhlova V.A.
    Svet V.D.
    Sapozhnikov O.A.
    Bulletin of the Russian Academy of Sciences: Physics, 2018, 82 (5) : 507 - 511