Identifying the model of AC/DC parallel transmission system on line is the precondition for realizing HVDC wide-area damp control. A method of identifying AC/DC parallel transmission system's model on line by WAMS data with limited length is put forward. Supposed that it's a SIMO system, the theory of identifying AC/DC parallel transmission system model is analyzed. Based on the theory, the arithmetic of identifying the Prony model's parameters and the formula of calculating the time spent on the process are deduced with the theory of AR model. The time relayed on transmission in communication net is calculated by using the GPS clock of PMU. The process of identifying the HVDC model is speeded up more due to the distributed realization of all the arithmetic's steps in WAMS center. The research about Gui-Guang HVDC line in South Power has proved that the method is valid and reliable.
引用
收藏
页码:48 / 53
相关论文
共 50 条
  • [31] Stability Analysis of AC/DC Power Transmission System based on Bifurcation Theories
    Yang, X.
    Chen, Y.
    Shu, H. L.
    2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 327 - +
  • [32] Stability Analysis of AC/DC Power Transmission System Based on Bifurcation Theory
    Yang, Xiu
    Jin, Yi-Xiong
    Chen, Yu
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [33] STUDY OF FAST SYNCHRONOUS-RECLOSING METHOD FOR PARALLEL AC LINE FAULT IN AC/DC POWER TRANSMISSION-SYSTEM
    MIZUKAMI, Y
    DOI, H
    KATSUKI, K
    SHIMOMURA, T
    IYODA, I
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (06): : 1135 - 1141
  • [34] Decentralized Coordinated Robust Adaptive Control for AC/DC Interconnected Power Systems Based on WAMS
    Li, Xingyuan
    Yan, Quan
    Hu, Yuying
    2008 IEEE ASIA PACIFIC CONFERENCE ON CIRCUITS AND SYSTEMS (APCCAS 2008), VOLS 1-4, 2008, : 1896 - 1899
  • [35] Digital simulation of AC/DC hybrid transmission system
    Yong, J
    Wu, XC
    Du, ZM
    Jin, XM
    Wang, YH
    Zhang, DH
    Rittiger, J
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 1405 - 1410
  • [36] WAMS based robust HVDC control considering model imprecision for AC/DC power systems using sliding mode control
    Weng, Hua
    Xu, Zheng
    ELECTRIC POWER SYSTEMS RESEARCH, 2013, 95 : 38 - 46
  • [37] Flexible Series/Parallel AC-DC-AC Motor Drive System
    Jacobina, Cursino Brandao
    Rocha, Nady
    de Almeida Carlos, Gregory Arthur
    dos Santos, Euzeli Cipriano, Jr.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (01) : 259 - 270
  • [38] A mathematical model for the loadability analysis of a simultaneous AC-DC power transmission system
    Alam, Mohammad Tawhidul
    Ahsan, Q.
    ELECTRICAL ENGINEERING, 2018, 100 (03) : 1901 - 1911
  • [39] A Coupled Virtual Impedance for Parallel AC/DC Converter Based Power Electronics System
    He, Jinwei
    Du, Liyang
    Liang, Beihua
    Li, Yunwei
    Wang, Chengshan
    IEEE TRANSACTIONS ON SMART GRID, 2019, 10 (03) : 3387 - 3400
  • [40] Study on Power System Disturbance Identification and Location Based on WAMS
    Qin, Xiaohui
    Li, Baiqing
    Guo, Qiang
    Hong, Shen
    Zhou, Qinyong
    Bi, Tianshu
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,