Myelin water imaging of in vivo and ex vivo human brains using multi-echo gradient echo at 3T and 7T

被引:0
|
作者
Xu, Guojun [1 ]
Zhao, Zhiyong [2 ]
Zhu, Qinfeng [1 ]
Zhu, Keqing [3 ,4 ,5 ,6 ]
Zhang, Jing [3 ,4 ,5 ,6 ]
Wu, Dan [1 ]
机构
[1] Zhejiang Univ, Dept Biomed Engn, Coll Biomed Engn & Instrument Sci, Key Lab Biomed Engn Minist Educ, Hangzhou, Peoples R China
[2] Zhejiang Univ, Childrens Hosp, Natl Clin Res Ctr Child Hlth, Sch Med, Hangzhou, Peoples R China
[3] Zhejiang Univ, China Brain Bank, Sch Med, Hangzhou, Peoples R China
[4] Zhejiang Univ, Dept Neurol, Affiliated Hosp 2,Sch Med, Key Lab Med Neurobiol Zhejiang Prov, Hangzhou, Peoples R China
[5] Zhejiang Univ, Dept Neurobiol, Sch Med, Hangzhou, Peoples R China
[6] Zhejiang Univ, First Affiliated Hosp & Sch Med, Dept Pathol, Hangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
multi-echo gradient-echo; myelin water fraction; 3; T; 7; ex vivo; histological staining; MRI; RELAXATION; SCLEROSIS; FRACTION; POSTMORTEM; VISUALIZATION; COMPONENT; WHOLE; TIME;
D O I
10.1002/mrm.30310
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the myelin water fraction (MWF) measurements between 3 T and 7 T and between in vivo and ex vivo human brains, and to investigate the relationship between multi-echo gradient-echo (mGRE)-based 3D MWF and myelin content using histological staining, which has not been validated in the human brain. Methods: In this study, we performed 3D mGRE-based MWF measurements on five ex vivo human brain hemispheres and five healthy volunteers at 3 T and 7 T with 1mm isotropic resolution. The data were fitted with the T-2* based on a three compartment complex-valued model to estimate MWF. We obtained myelin basic protein (MBP) staining from two tissue blocks and co-registered the MWF map and histology image for voxel-wise correlation between the two. Results: The MWF values measured from 7 T were overall higher than 7 T, but data between the two field strength demonstrated high correlations both in vivo (r=0.88) and ex vivo (r=0.83) across 19 white matter regions. Moreover, the MWF measurements showed a good agreement between in vivo and ex vivo assessments at 3 T (r=0.61) and 7 T (r=0.54). Based on MBP staining, the MWF values exhibited strong positive correlations with myelin content on both 3 T (r=0.68 and r=0.78 for the two tissue blocks) and 7 T (r=0.64 and r=0.82 for the two tissue blocks). Conclusion: The findings demonstrated that the mGRE-based MWF mapping can be used to quantify myelin content in the human brain, despite the field-strength dependency of the measurements.
引用
收藏
页码:803 / 813
页数:11
相关论文
共 50 条
  • [21] High-resolution in vivo imaging of human locus coeruleus by magnetization transfer MRI at 3T and 7T
    Priovoulos, Nikos
    Jacobs, Heidi I. L.
    Ivanov, Dimo
    Uludag, Kamil
    Verhey, Frans R. J.
    Poser, Benedikt A.
    NEUROIMAGE, 2018, 168 : 427 - 436
  • [22] Mechanisms of T2* anisotropy and gradient echo myelin water imaging
    Lee, Jongho
    Nam, Yoonho
    Choi, Joon Yul
    Kim, Eung Yeop
    Oh, Se-Hong
    Kim, Dong-Hyun
    NMR IN BIOMEDICINE, 2017, 30 (04)
  • [23] Myelin water imaging from multi-echo T2 MR relaxometry data using a joint sparsity constraint
    Nagtegaal, Martijn
    Koken, Peter
    Amthor, Thomas
    de Bresser, Jeroen
    Maedler, Burkhard
    Vos, Frans
    Doneva, Mariya
    NEUROIMAGE, 2020, 219
  • [24] Short Echo Spectroscopic Imaging of the Human Brain at 7T Using Transceiver Arrays
    Avdievich, N. I.
    Pan, J. W.
    Baehring, J. M.
    Spencer, D. D.
    Hetherington, H. P.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) : 17 - 25
  • [25] Multi-Echo-Based Echo-Planar Spectroscopic Imaging Using a 3T MRI Scanner
    Furuyama, Jon K.
    Burns, Brian L.
    Wilson, Neil E.
    Thomas, M. Albert
    MATERIALS, 2011, 4 (10): : 1818 - 1834
  • [26] Optimized multi-echo gradient-echo magnetic resonance imaging for gray and white matter segmentation in the lumbosacral cord at 3 T
    Bueler, Silvan
    Yiannakas, Marios C.
    Damjanovski, Zdravko
    Freund, Patrick
    Liechti, Martina D.
    David, Gergely
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [27] Optimized multi-echo gradient-echo magnetic resonance imaging for gray and white matter segmentation in the lumbosacral cord at 3 T
    Silvan Büeler
    Marios C. Yiannakas
    Zdravko Damjanovski
    Patrick Freund
    Martina D. Liechti
    Gergely David
    Scientific Reports, 12
  • [28] In vivo Measurement of Longitudinal Relaxation Time of Human Blood by Inversion-recovery Fast Gradient-echo MR Imaging at 3T
    Shimada, Kazuki
    Nagasaka, Tatsuo
    Shidahara, Miho
    Machida, Yoshio
    Tamura, Hajime
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2012, 11 (04) : 265 - 271
  • [29] Correcting Dynamic Distortions in 7T Echo Planar Imaging using a Jittered Echo Time Sequence
    Dymerska, Barbara
    Poser, Benedikt A.
    Bogner, Wolfgang
    Visser, Eelke
    Eckstein, Korbinian
    Cardoso, Pedro
    Barth, Markus
    Trattnig, Siegfried
    Robinson, Simon D.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (05) : 1388 - 1399
  • [30] Comparison of 3T and 7T magnetic resonance imaging for direct visualization of finger flexor pulley rupture: an ex-vivo study
    Bayer, Thomas
    Baechter, Lilly
    Lutter, Christoph
    Janka, Rolf
    Uder, Michael
    Schoeffel, Voelker
    Roemer, Frank W.
    Nagel, Armin M.
    Heiss, Rafael
    SKELETAL RADIOLOGY, 2024, 53 (11) : 2469 - 2476