A sequence-activatable dual-locked fluorescent probe for simultaneous detection of hypochlorous acid and peroxynitrite during drug-induced liver injury

被引:0
|
作者
Liu, Caiyun [1 ]
Yan, Tingyi [1 ]
Cai, Xinyu [1 ]
Zhu, Hanchuang [1 ]
Zhang, Peng [2 ]
Liu, Xueting [1 ]
Rong, Xiaodi [1 ]
Wang, Kun [1 ]
Wang, Yao [1 ]
Shu, Wei [2 ]
Zhu, Baocun [1 ]
机构
[1] Univ Jinan, Sch Water Conservancy & Environm, Jinan 250022, Peoples R China
[2] Shandong Univ Technol, Sch Life Sci & Med, Zibo 255000, Peoples R China
关键词
Fluorescent probe; Hypochlorous acid; Peroxynitrite; Drug-induced liver injury; Dual-locked probe; ACETAMINOPHEN HEPATOTOXICITY; ENDOGENOUS PEROXYNITRITE; RECENT PROGRESS; OXIDANT STRESS; CANCER-CELLS; SUPEROXIDE; MITOCHONDRIA; MICE;
D O I
10.1016/j.talanta.2024.127408
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Drug-induced liver injury (DILI) is a crucial factor that poses a significant threat to human health. DILI process leads to the changes of reactive oxygen species and reactive nitrogen species content in cells, which leads to oxidative and nitrosative stress in cells. However, the high reactivity of hypochlorous acid (HOCl) and peroxynitrite (ONOO ), combined with a lack of in situ imaging techniques, has hindered a detailed understanding of their roles in DILI. Therefore, this paper reports a novel sequence-activatable dual-locked molecular probe HA-P3 for the identification and imaging of two DILI-related biomarkers. First, HA-P3 selectively reacts with reactive oxygen species HOClto leave the recognition receptor diethyl thiocarbamate to form HA-P2. Subsequently, HA- P2 reacts with ONOO , liberating the fluorophore 4-hydroxy-1,8-naphthalimide, which emits a strong fluorescence signal. The two-step reaction effectively reduces the probability of false positive in predicting DILI. HA-P3 achieved the sensitive detection of HOCland ONOO- in different cells and zebrafish. Furthermore, HA-P3 can distinguish between normal liver cells and hepatoma cells and monitored the elevated levels of HOCland ONOO during acetaminophen (APAP)-induced cellular damage. It is worth noting that in the APAP-induced mouse model, the positive correlation between HOCland ONOO- and DILI was revealed, providing strong direct evidence for the relationship between oxidative/nitrosative stress and DILI.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Development of peroxynitrite-responsive fluorescence probe for recognition of drug-induced liver injury
    Wang, Bing -Dan
    Wei, Ran
    Gao, Meng-Jiao
    Wang, Yi-Hua
    Zhang, Chu-Fan
    Guo, Xiao-Han
    Liang, Zi-shan
    Zhou, Jia-Tong
    Sun, Jia-Xing
    Xu, Jia-Qi
    Kang, Yan-Fei
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 283
  • [22] A superoxide anion activatable near-infrared fluorescent probe with a large Stokes shift for imaging of drug-induced liver injury
    Wang, Qian-Qian
    We, Shi-Peng
    Yang, Jin-He
    Li, Jiao
    Sun, Xue-Yu
    Yang, Tian-Tian
    Mao, Guo-Jiang
    MICROCHEMICAL JOURNAL, 2024, 200
  • [23] Rational design of dual ratiometric photoacoustic and fluorescent probe for reliable imaging and quantitative detection of endogenous CO during drug-induced liver injury and repair
    Liu, Li
    Xu, Jingyuan
    Zhang, Shuping
    Chen, Hui
    Wang, Liping
    Shen, Xing-can
    Chen, Hua
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 367
  • [24] A novel NIR-II fluorescent probe for hydrogen peroxide detection in drug-induced liver injury
    Chen, Huiyu
    Zhou, Hui
    Zhang, Xinyue
    Ding, Yancheng
    Zhang, Xiaolong
    Xu, Qinqin
    Wang, Ben
    Yin, Chao
    Fan, Quli
    CHEMICAL COMMUNICATIONS, 2024, 60 (71) : 9618 - 9621
  • [25] A dual-emission fluorescent probe for simultaneous detection of singlet oxygen and hypochlorous acid in lipid droplets
    Zhao, Wanqing
    Zhang, Shengtao
    Yan, Jiali
    Xu, Pengyue
    Li, Bin
    Zhang, Yongmin
    Li, Jianli
    Wu, Shaoping
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 412
  • [26] Endoplasmic reticulum-targeted fluorescent probe with aggregation-induced emission features for imaging peroxynitrite in drug-induced liver injury model
    Zhang, Haixia
    Yang, Yating
    Xie, Feiran
    Lan, Yu
    Li, Lin
    Song, Zhenlei
    Gao, Lu
    Huang, Yi
    Xiao, Peihong
    BIOSENSORS & BIOELECTRONICS, 2024, 262
  • [27] A Dual-Emissive Phosphorescent Polymeric Probe for Exploring Drug-Induced Liver Injury via Imaging of Peroxynitrite Elevation In Vivo
    Chen, Zejing
    Meng, Xiangchun
    Zou, Liang
    Zhao, Menglong
    Liu, Shujuan
    Tao, Peng
    Jiang, Jiayang
    Zhao, Qiang
    ACS APPLIED MATERIALS & INTERFACES, 2020, 12 (11) : 12383 - 12394
  • [28] A Highly Sensitive and Selective Near-Infrared Fluorescent Probe for Imaging Peroxynitrite in Living Cells and Drug-Induced Liver Injury Mice
    Chai, Xianzhi
    Li, Bohan
    Chen, Chi
    Zhang, Weijian
    Sun, Lulu
    Han, Hai-Hao
    Zhang, Yafei
    Sun, Shasha
    Yang, Jianming
    Zhang, Junji
    He, Xiao-Peng
    ANALYTICAL CHEMISTRY, 2023, 95 (13) : 5747 - 5753
  • [29] Endoplasmic Reticulum Targeting Ratiometric Fluorescent Probe for Carboxylesterase 2 Detection in Drug-Induced Acute Liver Injury
    Tian, Xiangge
    Yan, Fei
    Zheng, Jingyuan
    Cui, Xiaolin
    Feng, Lei
    Li, Sheng
    Jin, Lingling
    James, Tony D.
    Ma, Xiaochi
    ANALYTICAL CHEMISTRY, 2019, 91 (24) : 15840 - 15845
  • [30] A turn-on fluorescent probe for imaging of hydroxyl radicals in drug-induced liver injury
    Yu, Mengshan
    Xiang, Hanyue
    Taledaohan, Ayijiang
    Fu, Wenzhuo
    Li, Hongyu
    Wang, Yuji
    Xiao, Nao
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2025, 329