Orthotropic properties of cancellous bone modelled as parameterized cellular material

被引:15
|
作者
Institute of Fundamental Technological Research, Polish Academy of Sciences, ul. Śwįetokrzyska 21, 00-049 Warsaw, Poland [1 ]
机构
来源
Comput. Methods Biomech. Biomed. Eng. | 2006年 / 3卷 / 135-147期
关键词
Elasticity - Finite element method - Parameterization - Structural design - Bone - Constitutive models - Mesh generation - Stiffness matrix;
D O I
10.1080/10255840600751473
中图分类号
学科分类号
摘要
Analysis of stresses and strains in bone tissues and simulation of their adaptive remodelling require exhaustive information about distribution of constitutive properties of cancellous bone and their relationships to microstructural parameters. Homogenization of equivalent trabecular microstructures appears to be an advantageous tool for this task. In this study, parameterized orthotropic constitutive models of cancellous bone are derived from finite element analysis of repeatable microstructure cells. The models, based on a space-filling dodecahedron, are fully three-dimensional and are parameterized with four shape parameters. Variation of the parameters allows to imitate most of typical microstructure patterns observed in real bones, along with a variety of intermediate geometries. Finite element models of cells are generated by a special-purpose structured mesh generator for any arbitrary set of shape parameter values. Static numerical tests are performed for an exhaustive number of parameter value sets (microstructure instances). Coefficients of elastic orthotropic stiffness matrix are determined as tabularized functions of elastic constants versus the shape parameters. Additionally, they are correlated to apparent density and principal fabric tensor values. Comparison of the results with micro-FE data obtained for a large set of cancellous bone specimens proves a good agreement. © 2006 Taylor & Francis Ltd.
引用
收藏
相关论文
共 50 条
  • [31] Trabecular bone adaptation with an orthotropic material model
    Miller, Z
    Fuchs, MB
    Arcan, M
    JOURNAL OF BIOMECHANICS, 2002, 35 (02) : 247 - 256
  • [32] ELASTIC PROPERTIES OF ORTHOTROPIC MATERIAL AT STRETCHING
    ANTIPOVA, IA
    MOROZOV, AS
    SHAIKOSHAIKOVSKII, AG
    ZAVODSKAYA LABORATORIYA, 1975, 41 (05): : 612 - 614
  • [33] EFFECTS OF FREEZE-THAW CYCLING ON MATERIAL PROPERTIES OF CANCELLOUS CERVINE BONE AS CHARACTERIZED BY NANOINDENTATION
    Landauer, Alexander K.
    Yuya, Philip A.
    Kuxhaus, Laurel
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT A, 2014,
  • [34] Mechanical properties of cancellous bone of the distal humerus
    Dunham, CE
    Takaki, SE
    Johnson, JA
    Dunning, CE
    CLINICAL BIOMECHANICS, 2005, 20 (08) : 834 - 838
  • [35] Dynamic behavior and microstructural properties of cancellous bone
    Laporte, S.
    David, F.
    Bousson, V.
    Pattofatto, S.
    DYMAT 2009: 9TH INTERNATIONAL CONFERENCE ON THE MECHANICAL AND PHYSICAL BEHAVIOUR OF MATERIALS UNDER DYNAMIC LOADING, VOL 1, 2009, : 895 - +
  • [36] Numerical modelling of cancellous bone damage using an orthotropic failure criterion and tissue elastic properties as a function of the mineral content and microporosity
    Megias, Raquel
    Vercher-Martinez, Ana
    Belda, Ricardo
    Luis Peris, Jose
    Larrainzar-Garijo, Ricardo
    Giner, Eugenio
    Javier Fuenmayor, F.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 219
  • [37] Contribution of the reflection to the attenuation properties of cancellous bone
    Klinge, Sandra
    Hackl, Klaus
    COMPLEX VARIABLES AND ELLIPTIC EQUATIONS, 2012, 57 (2-4) : 425 - 436
  • [38] Bone quality issues and matrix properties in OP cancellous bone
    Zioupos, P.
    Cook, R.
    Aspden, R. M.
    Coats, A. M.
    MEDICINE MEETS ENGINEERING, 2008, 133 : 238 - 245
  • [39] MECHANICAL-PROPERTIES OF CORTICAL AND CANCELLOUS BONE
    LEREIM, P
    ACTA ORTHOPAEDICA SCANDINAVICA, 1988, 59 (02): : 215 - 216
  • [40] CANCELLOUS BONE FROM HEAD OF TIBIA AS AUTOLOGOUS GRAFT MATERIAL
    HEIM, U
    DAMURTHUR, F
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1977, 89 (02) : 211 - 217