Fast complete Mueller matrix polarimetry microscopy using a single polarization camera

被引:0
|
作者
Wang, Tao [1 ]
Wang, Nan [1 ,2 ]
He, Sailing [1 ,2 ,3 ]
机构
[1] Zhejiang Univ, Natl Engn Res Ctr Opt Instruments, Coll Opt Sci & Engn, Ctr Opt & Electromagnet Res,Ningbo Innovat Ctr, Hangzhou 310058, Peoples R China
[2] Zhejiang Univ, Ningbo Res Inst, Ningbo Innovat Ctr, Ningbo 315100, Peoples R China
[3] Royal Inst Technol, Sch Elect Engn, Dept Electromagnet Engn, SE-10044 Stockholm, Sweden
基金
中国国家自然科学基金;
关键词
fast microscopic polarimetry; full Mueller matrix imaging; polarization camera; condition number;
D O I
10.1016/j.optlaseng.2024.108650
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We propose a fast microscopic polarimeter for complete Mueller matrix imaging by using two rotating retarders and one polarization camera. Our new design allows us to compute the full Mueller matrix by 6 measurements in only similar to 1.4s. The acquisition time is reduced by optimizing the sampling process. At the same time, the measurement precision is enhanced by minimizing the conditional numbers of the measurement matrices, compensating the pixel displacement, and calibrating the orientation of each polarization component in the system. As a demonstration, we use our fast polarimetry microscopy to measure the complete Mueller matrix for a garnet sample and cholesteric liquid crystal samples.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Polarization state transformation using two quarter wave plates: application to Mueller polarimetry
    Reddy, Salla Gangi
    Prabhakar, Shashi
    Chithrabhanu, P.
    Singh, R. P.
    Simon, R.
    APPLIED OPTICS, 2016, 55 (12) : B14 - B19
  • [42] Complete polarization characterization of single plasmonic nanoparticle enabled by a novel Dark-field Mueller matrix spectroscopy system
    Chandel, Shubham
    Soni, Jalpa
    Ray, Subir Kumar
    Das, Anwesh
    Ghosh, Anirudha
    Raj, Satyabrata
    Ghosh, Nirmalya
    SCIENTIFIC REPORTS, 2016, 6
  • [43] Complete polarization characterization of single plasmonic nanoparticle enabled by a novel Dark-field Mueller matrix spectroscopy system
    Shubham Chandel
    Jalpa Soni
    Subir kumar Ray
    Anwesh Das
    Anirudha Ghosh
    Satyabrata Raj
    Nirmalya Ghosh
    Scientific Reports, 6
  • [44] Snapshot imaging Mueller matrix polarimeter using polarization gratings
    Kudenov, Michael W.
    Escuti, Michael J.
    Hagen, Nathan
    Dereniak, Eustace L.
    Oka, Kazuhiko
    OPTICS LETTERS, 2012, 37 (08) : 1367 - 1369
  • [45] Single-shot measurement of polarization state at low light field using Mueller-mapping star test polarimetry
    Ning, Tianlei
    Li, Yanqiu
    Zhou, Guodong
    Liu, Ke
    Wang, Jiazhi
    OPTICS COMMUNICATIONS, 2021, 496
  • [46] Optical diagnosis of dengue virus infected human blood using Mueller matrix polarimetry
    Anwar, Shahzad
    Firdous, Shamaraz
    OPTICS AND SPECTROSCOPY, 2016, 121 (02) : 322 - 325
  • [47] Evaluating Tissue Mechanical Properties Using Quantitative Mueller Matrix Polarimetry and Neural Network
    Mi, Changjiang
    Shao, Conghui
    He, Honghui
    He, Chao
    Ma, Hui
    APPLIED SCIENCES-BASEL, 2022, 12 (19):
  • [48] Rapid structure sensing of suspended particles in water using particulate Mueller matrix polarimetry
    Lei, Junqiu
    Li, Jiajin
    Liu, Hongyuan
    Xiong, Zhihang
    Jiang, Feng
    Han, Baohui
    Yang, Jianxiong
    Liao, Ran
    MEASUREMENT, 2025, 246
  • [49] Optical diagnosis of dengue virus infected human blood using Mueller matrix polarimetry
    Shahzad Anwar
    Shamaraz Firdous
    Optics and Spectroscopy, 2016, 121 : 322 - 325
  • [50] Complete self-calibration compact binary magneto-optic rotator based Mueller matrix polarimetry
    Hua, Peidong
    Ding, Zhenyang
    Wang, Chenhuan
    Liu, Kun
    Jiang, Junfeng
    Yu, Yin
    Yao, X. Steve
    Liu, Tiegen
    OPTICS EXPRESS, 2021, 29 (19) : 30392 - 30408