Predictive current control for grid-connected inverters under unbalanced grid voltage

被引:0
|
作者
机构
[1] Nian, Heng
[2] Yu, Nisa
[3] Zeng, Rong
来源
Nian, H. (nianheng@zju.edu.cn) | 2013年 / Power System Technology Press卷 / 37期
关键词
Electric current control - Electric inverters - Electric power system control - Reactive power;
D O I
暂无
中图分类号
学科分类号
摘要
Based on the mathematic models of grid-connected inverter under unbalanced grid voltage, the control strategy were proposed to implement the balance of three-phase current, eliminate the ripple in active and reactive power, in which the current reference of the positive sequence and the negative sequence for the different control targets was deduced. And then, based on the two-phase stationary reference frame, a predictive current control scheme was proposed to implement the accurate control of the positive sequence and the negative sequence current, which can eliminate the bad effects to the operation performance of grid-connected inverter, caused by the current sampling delay and the sequence decomposition. The feasibility of the proposed algorithms and control strategy were validated by experimental studies on a 3 kVA grid side converter system.
引用
收藏
相关论文
共 50 条
  • [31] Study on model current predictive control method of PV grid-connected inverters systems with voltage sag
    Jin, N.
    Yang, F.
    Shang, S. Y.
    Tao, T.
    Liu, J. S.
    2016 INTERNATIONAL CONFERENCE ON NEW ENERGY AND FUTURE ENERGY SYSTEM (NEFES 2016), 2016, 40
  • [32] Current Improvement of a Grid-Connected Photovoltaic System under Unbalanced Voltage Conditions
    Mirhosseini, Mitra
    Pou, Josep
    Agelidis, Vassilios G.
    2013 IEEE ECCE ASIA DOWNUNDER (ECCE ASIA), 2013, : 66 - 72
  • [33] A Robust Predictive Current Control for Three-Phase Grid-Connected Inverters
    Castello Moreno, Jaime
    Espi Huerta, Jose M.
    Garcia Gil, Rafael
    Alejandro Gonzalez, Sergio
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (06) : 1993 - 2004
  • [34] Repetitive Predictive Control for Current Control of Grid-Connected Inverter Under Distorted Voltage Conditions
    Lunardi, Angelo
    Conde, Eliomar
    Assis, Jefferson
    Meegahapola, Lasantha
    Fernandes, Darlan A.
    Sguarezi Filho, Alfeu J.
    IEEE ACCESS, 2022, 10 : 16931 - 16941
  • [35] Decentralized Multivariable Vector Current Control of Grid-connected Voltage Source Inverters
    Sadabadi, Mahdieh S.
    Shafiee, Qobad
    IFAC PAPERSONLINE, 2020, 53 (02): : 12410 - 12415
  • [36] Synchronization technique of grid-connected PV inverter under unbalanced grid voltage
    Dang, Ke
    Zheng, Yuhao
    Yan, Gangui
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2015, 36 (01): : 87 - 94
  • [37] Multilevel direct current control for grid-connected inverters
    Schaefer, Markus
    Hofmann, Martin
    Raab, Sebastian
    Ackva, Ansgar
    2015 17TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'15 ECCE-EUROPE), 2015,
  • [38] Research on Control Strategy of Grid-connected Inverter Under Unbalanced Voltage Conditions
    Tao, Weiqing
    Gu, Zhixia
    Wang, Leqin
    Li, Jiaxi
    2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA), 2016,
  • [39] An optimal grid current control strategy with grid voltage observer (GVO) for LCL-filtered grid-connected inverters
    Dou, Xiaobo
    Jiao, Yang
    Yang, Kang
    Wu, Zaijun
    Gu, Wei
    Li, Haojie
    Tang, Xiaochen
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2018, 13 (05) : 777 - 784
  • [40] A Control Strategy of Grid-connected Photovoltaic Inverter under Unbalanced Voltage Conditions
    Cao, Wei
    Xu, Yonghai
    PROCEEDINGS OF 2016 17TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2016, : 209 - 213