Multifunctional spatial-potential resolved electrochemiluminescence biosensor for dual-channel simultaneous detection of hepatitis A virus and hepatitis C virus DNA

被引:3
|
作者
Wu, Di [1 ,2 ]
Cai, Qianqian [1 ,2 ]
Zhang, Jiajie [1 ,2 ]
Guo, Feng [3 ]
Jie, Guifen [1 ,2 ]
机构
[1] Qingdao Univ Sci & Technol, Key Lab Opt Elect Sensing & Analyt Chem Life Sci, MOE, Qingdao 266042, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
[3] Youjiang Med Univ Nationalities, Sch Lab Med, Baise 533000, Guangxi, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Electroluminescence; Spatial-potential resolution; Self-luminescent; Resonance energy transfer; Simultaneous detection;
D O I
10.1016/j.snb.2024.136597
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Highly sensitive simultaneous detection of dual-target is one of the main research directions of electrochemiluminescence (ECL), but the traditional three-electrode system makes it difficult to realize this aim. This work designed a multifunctional spatial-potential resolved ECL biosensor for dual-channel simultaneous detection of hepatitis A virus (HAV) and hepatitis C virus (HCV) DNA. Self-luminescent dual-ligand metal organic framework (D-MOF) and cerium MOF (Ce-MOF) were modified on two parts of the ITO electrode to achieve dualchannel simultaneous detection. One ligand of D-MOF acted as the luminophore and the other as the co-reactant, so D-MOF could emit excellent positive potential ECL signal without requiring external co-reactants. In channel A, the Ag nanoparticles (Ag NPs) quenching probes were introduced to D-MOF through hybridization of HAV with "Y" type DNA. Positive potential signal of D-MOF was decreased for HAV DNA detection based on resonance energy transfer (RET). In channel B, the CdSe quantum dots (QDs) were introduced to Ce-MOF through hybridization of HCV with "Y" type DNA. Due to the excellent ECL performance of CdSe QDs, negative potential signal was increased for HCV DNA detection. In this work, an ingenious spatial-potential resolved ECL biosensor was developed for simultaneous detection of dual-target by simple sealing film isolation, which opened a new strategy for dual-target detection in general ECL assays with three-electrode system.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Development and evaluation of a new detection tool—visual DNA microarray for simultaneous and specific detection of human immunodeficiency virus type-1 and hepatitis C virus
    Jingfeng Tang
    Li Zhou
    Lian Lian Duan
    Yang Feng
    Xuan Cao
    Yefu Wang
    Molecular Biology Reports, 2011, 38 : 5341 - 5348
  • [42] An upconversion fluorescent resonant energy transfer biosensor for hepatitis B virus (HBV) DNA hybridization detection
    Zhu, Hao
    Lu, Feng
    Wu, Xing-Cai
    Zhu, Jun-Jie
    ANALYST, 2015, 140 (22) : 7622 - 7628
  • [43] Spatial-Potential-Color-Resolved Bipolar Electrode Electrochemiluminescence Biosensor Using a CuMoOx Electrocatalyst for the Simultaneous Detection and Imaging of Tetracycline and Lincomycin
    Li, Hongkun
    Cai, Qianqian
    Wang, Yuehui
    Jie, Guifen
    Zhou, Hong
    ANALYTICAL CHEMISTRY, 2024, 96 (18) : 7073 - 7081
  • [44] Evolving a multiple assay system to detect hepatitis B virus DNA, hepatitis C and hepatitis E virus RNA by simultaneous in patients with liver disease who hav coinfection or superinfection
    Garg, G.
    Asim, M.
    Kar, P.
    Das, B. C.
    Husain, S. A.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2008, 23 : A38 - A38
  • [45] Simultaneous detection of multiplex-amplified human immunodeficiency virus type 1 RNA, hepatitis C virus RNA, and hepatitis B virus DNA using a flow cytometer microsphere-based hybridization assay
    Defoort, JP
    Martin, M
    Casano, B
    Prato, S
    Camilla, C
    Fert, V
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (03) : 1066 - 1071
  • [46] High throughput assay for the simultaneous or separate detection of human immunodeficiency virus (HIV) and hepatitis type C virus (HCV)
    McDonough, SH
    Giachetti, C
    Yang, Y
    Kolk, DP
    Billyard, E
    Mimms, L
    INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 1998, 25 (2-3): : 164 - 169
  • [47] Qualitative multiplex RT-PCR for simultaneous detection of hepatitis C virus and human immunodeficiency virus in plasma samples
    Adami, V
    Falasca, E
    Dorotea, L
    Malangone, W
    Astori, G
    Marini, L
    Biffoni, F
    Rinaldi, C
    Degrassi, A
    Pipan, C
    CLINICAL MICROBIOLOGY AND INFECTION, 2004, 10 (12) : 1075 - 1080
  • [48] Development and evaluation of a new detection tool-visual DNA microarray for simultaneous and specific detection of human immunodeficiency virus type-1 and hepatitis C virus
    Tang, Jingfeng
    Zhou, Li
    Duan, Lian Lian
    Feng, Yang
    Cao, Xuan
    Wang, Yefu
    MOLECULAR BIOLOGY REPORTS, 2011, 38 (08) : 5341 - 5348
  • [49] Detection of Hepatitis B Virus DNA Hybridization Based on Dual Gold Nano-probes
    Xing Ya-Si
    Zou Neng-Li
    Mao Hong-Ju
    Xu Xia
    Ge Yu-Qing
    Jin Qing-Hui
    Zhao Jian-Long
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2012, 33 (07): : 1420 - 1425
  • [50] Rapid detection of the genotyping of hepatitis C virus using DNA chip with coloration methods
    张翼冠
    毛红菊
    顾士民
    许宝建
    赵建龙
    董子明
    中华肝脏病杂志, 2004, (05) : 50 - 52