Comparison of Nondestructive Methods for Detecting Reinforcing Bar Placement

被引:0
|
作者
Burney, David C. [1 ]
Kurtis, Kimberly E. [2 ]
Jacobs, Laurence J. [3 ]
Sherman, Ryan J. [4 ]
机构
[1] Lewis & Clark Coll, Portland, OR 97219 USA
[2] Georgia Inst Technol, Sch Mat Sci & Engn, Civil & Environm Engn, Atlanta, GA USA
[3] Georgia Inst Technol, Civil & Environm & Mech Engn, Atlanta, GA USA
[4] Georgia Inst Technol, Civil & Environm Engn, Atlanta, GA USA
关键词
cover; dowel; eddy current; epoxy-coated; galvanized; ground-penetrating radar (GPR); quality assurance; stainless steel; CONCRETE;
D O I
10.14359/51742260
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Despite improvements in nondestructive testing (NDT) technologies, the quality assurance of concrete reinforcing bar placement is still primarily conducted with conventional methodologies, which can be time-consuming, ineffective, and damaging to the concrete components. This study investigated the performance of two commercially available cover meters and one groundpenetrating radar (GPR) device. A cover meter was found to have the greatest accuracy for depths smaller than 3.19 in. (81.0 mm), while the GPR performed better for greater depths. The effect of reinforcing bar depth, diameter, and type; neighboring reinforcing bars; and concrete conditioning on the performance of the devices was quantified. The use of epoxy-coated reinforcing bar, galvanized reinforcing bar, and stainless-steel reinforcing bar were found to have a negligible effect on cover meter accuracy. A model was developed to predict the precision of the GPR post-measurement analysis given a depth and concrete dielectric constant.
引用
收藏
页码:27 / 40
页数:14
相关论文
共 50 条
  • [21] NONDESTRUCTIVE METHODS OF DETECTING CURTOBACTERIUM-FLACCUMFACIENS PV FLACCUMFACIENS IN MUNGBEAN SEEDS
    DIATLOFF, A
    WONG, WC
    WOOD, BA
    LETTERS IN APPLIED MICROBIOLOGY, 1993, 16 (05) : 269 - 273
  • [22] The Effect of the Realkalisation on the Corroded Reinforcing Bar
    Qu Wenjun
    Wang Kun
    Xiong Yan
    7TH INTERNATIONAL CONFERENCE ON STRUCTURAL ANALYSIS OF HISTORIC CONSTRUCTIONS: STRENGTHENING AND RETROFITTING, PTS 1 AND 2, 2010, 133-134 : 1201 - +
  • [23] EPOXY COATED REINFORCING BAR.
    Mulligan, Wayne
    1978, : 19 - 26
  • [24] CLEAVAGE FRACTURE OF BENT REINFORCING BAR
    PUSSEGODA, LN
    METALS TECHNOLOGY, 1982, 9 (AUG): : 312 - 316
  • [25] Stainless steel for reinforcing bar in concrete
    McGum, JF
    McKean, BA
    ENVIRONMENTALLY INDUCED CRACKING OF METALS, PROCEEDINGS, 2000, : 253 - 263
  • [26] New advances in the reinforcing bar marking
    Comand, P.
    Martecchini, F.
    Stal', 2003, (05): : 52 - 54
  • [27] Thoracic Impalement by a Steel Reinforcing Bar
    Ha, Jinny
    Sikorski, Robert A.
    O'Connor, James V.
    AMERICAN SURGEON, 2018, 84 (01) : E6 - E8
  • [28] FATIGUE STUDIES OF REINFORCING BAR STEEL
    MONTILLA, J
    TEIXEIRA, G
    QUINTERO, O
    BYRNE, JG
    ACTA CIENTIFICA VENEZOLANA, 1979, 30 (06): : 586 - 587
  • [29] Comparison of outcomes for gastrostomy placement methods.
    Bankhead, R
    Rolandelli, R
    Fisher, C
    Migaly, J
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2002, 75 (02): : 427S - 427S
  • [30] Comparison of Different Methods for Optimal Placement of PMUs
    Almutairi, A. M.
    Milanovic, J. V.
    2009 IEEE BUCHAREST POWERTECH, VOLS 1-5, 2009, : 1624 - 1629