Experimental study on water mist evaporative cooling in power machine exhaust system

被引:0
|
作者
Yuan, Jiang-Tao [1 ,2 ]
Yang, Li [1 ]
Jin, Ren-Xi [2 ]
Wang, Xiao-Chuan [1 ]
Zhang, Jian [1 ]
机构
[1] College of Naval Architecture and Power, Naval University of Engineering, Wuhan 430033, China
[2] Training Department, Naval Submarine Academy, Qingdao 266042, China
关键词
Cooling water - Gas temperature - Evaporation - Exhaust systems (engine) - Cooling - Evaporative cooling systems - Gases;
D O I
暂无
中图分类号
学科分类号
摘要
Aiming at understanding the cooling performance of the devised water mist evaporative cooler for the engine exhaust gas, an exhaust gas spray cooling test-bed was set up, and the gas temperature and pressure loss was measured when the water was sprayed into the exhaust gas using the designed protected type gas temperature measuring device and the pressure loss measuring device. Results indicate that when the cooler sprays water mist into the exhaust gas, the gas temperature drops immediately to steady temperature in 80 s. The pressure loss decreases after introducing the water mist into the exhaust gas. The bigger the atomizing pressure, the bigger the water flow rate, the better the spray cooling effect, and the smaller the pressure loss. The saturation temperature of the liquid water corresponding to the gas outlet pressure can be regarded as the gas cooling terminal temperature.
引用
收藏
页码:461 / 464
相关论文
共 50 条
  • [31] Research on the isobaric evaporative cooling system of power thyristor
    Cai, J
    Cao, HL
    Gu, GB
    IECON 2004 - 30TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOL. 1, 2004, : 715 - 718
  • [32] Study on evaporative cooling system based on water sprinkling over factory roof
    Takeda, Hitoshi
    Ohashi, Hidemitsu
    AIJ Journal of Technology and Design, 2009, 15 (31) : 807 - 812
  • [33] Experimental Study of Solar Water Desalination Using Evaporative Cooling (ICSEWEN19)
    Asfar, Khaled
    Keewan, Ashraf
    Shkokany, Abdalhadi
    SUSTAINABLE ENERGY-WATER-ENVIRONMENT NEXUS IN DESERTS, 2022, : 183 - 188
  • [34] Experimental study on the operating characteristics of self-circulating evaporative inner cooling system for high power rectifier equipment
    Yan, Jing
    Ruan, Lin
    ENERGY REPORTS, 2022, 8 : 226 - 231
  • [35] Study of cooling system with water mist sprayers - Fundamental examination of particle size distribution and cooling effects
    Hideki, Yamada
    Gyuyoug, Yoon
    Masaya, Okumiya
    Hiroyasu, Okuyama
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 1389 - +
  • [36] Study of Cooling System with Water Mist Sprayers: Fundamental Examination of Particle Size Distribution and Cooling Effects
    Yamada, Hideki
    Yoon, Gyuyoung
    Okumiya, Masaya
    Okuyama, Hiroyasu
    BUILDING SIMULATION, 2008, 1 (03) : 214 - 222
  • [37] Study of cooling system with water mist sprayers: Fundamental examination of particle size distribution and cooling effects
    Hideki Yamada
    Gyuyoung Yoon
    Masaya Okumiya
    Hiroyasu Okuyama
    Building Simulation, 2008, 1 : 214 - 222
  • [38] Experimental study on direct evaporative cooling for free cooling of data centers
    Li, Chao
    Mao, Ruiyong
    Wang, Yong
    Zhang, Jun
    Lan, Jiang
    Zhang, Zujing
    ENERGY, 2024, 288
  • [39] Experimental and numerical study on water mist suppression system on room fire
    Yang, Peizhong
    Liu, Tao
    Qin, Xian
    BUILDING AND ENVIRONMENT, 2010, 45 (10) : 2309 - 2316
  • [40] Experimental study of the potential of eucalyptus fibres for evaporative cooling
    Dogramaci, Pervin Abohorlu
    Riffat, Saffa
    Gan, Guohui
    Aydin, Devrim
    RENEWABLE ENERGY, 2019, 131 : 250 - 260