Determination of Vanadium and Nickel in Crude Oil by ICP-MS/MS Based on Reaction Gas Mixture

被引:0
|
作者
基于反应气混合物的 ICP-MS/MS 测定原油中的钒和镍
机构
[1] Cai, Song-Tao
[2] Huang, Ying-Xiu
[3] Yuan, Liang
[4] Dai, Yu-Xuan
[5] Mo, Yao-Kun
[6] Huang, Jian-Hua
来源
Huang, Jian-Hua (jhhuang85@163.com) | 2025年 / 45卷 / 01期
关键词
Catalytic cracking;
D O I
10.3964/j.issn.1000-0593(2025)01-0101-06
中图分类号
学科分类号
摘要
The content and ratio of metal elements V and Ni in crude oil play an important role in understanding the characterizing depositional environment and organic matter types of crude oil. However, in the process of crude oil refining, V and Ni, as harmful metal elements in the catalytic Cracking process of crude oil, will reduce the activity of the catalyst, and even lead to poisoning of the catalyst and serious corrosion of equipment. Before refining, V and Ni must be removed from the crude oil. In addition, V and Ni are mutagenic and carcinogenic, and it is becoming increasingly important to identify or monitor the Potential danger of V and Ni in crude oil entering the environment. Therefore, conducting highly sensitive and accurate determination of V and Ni content in crude oil is of great significance. This paper proposes a new strategy for determining V and Ni in crude oil by inductively coupled plasma tandem mass spectrometry (ICP-MS/MS). ICP-MS/MS directly analyzes the crude oil sample after diluting aviation kerosene. For the spectral interferences of V and Ni, in the MS/MS mode, the reaction gas mixture NH3/He/H2 is composed of NH3/He (He is the buffer gas), and H2 is used as the reaction gas. Based on the fact that V+ does not react with NH3/He/H2, but the interfering ions of V+ react with NH3/He/H2, the on-mass method was used to eliminate the interference, and V- was selected for determination. Based on the mass shift reaction between Ni+ and NHj/He/ H2, the interference was eliminated by the mass shift method, and the interference-free Cluster ion Ni(NH3)f was selected for determination. By comparing it with the NH3/He reaction mode, it is found that for the determination of V, adding H2 as a reaction gas can quickly remove the interference of large ions and cooperate with NH3 to eliminate the interference of oxide ions. For the determination of Ni, adding H2 as reaction gas can promote the formation of fully hydrogenated adducts (—NH3), thus increasing the yield of NKNHs.)^. In the NH3/He/H2 reaction mode, the background equivalent concentration (BEC) of V and Ni is lower, the sensitivity of Ni is higher, and the limit of detection (LOD) of V and Ni is as low as 0. 83 and 3. 76 ng • kg-1, respectively. The limit of quantification (LOQ) is 2. 77 and 12. 5 ng • kg-1, respectively. The accuracy and precision of the method were evaluated by analyzing the Standard reference material NIST SRM 1634c and the spiked recovery experiment, respectively. The results showed that the method's determination results were consistent with the certified values of the Standard reference material. The spiked recoveries of V and Ni were 97. 7% and 103%, respectively, and the relative Standard deviation (RSD) was 1. 8% and 1. 9%, respectively. The developed method avoids the complicated sample pretreatment process and has the characteristics of simple and rapid Operation, with high sensitivity, accuracy, and good precision. It is suitable for detecting V and Ni in crude oil and can provide a theoretical basis for removing V and Ni in the deep processing of crude oil. © 2025 Science Press. All rights reserved.
引用
收藏
页码:101 / 106
相关论文
共 50 条
  • [21] Collision/Reaction Cell ICP-MS with Shielded Torch and Sector Field ICP-MS for the Simultaneous Determination of Selenium Isotopes in Biological Matrices
    Al-Saad, Khalid A.
    Amr, Mohammed A.
    Helal, Abdulfattah I.
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2011, 140 (01) : 103 - 113
  • [22] Collision/Reaction Cell ICP-MS with Shielded Torch and Sector Field ICP-MS for the Simultaneous Determination of Selenium Isotopes in Biological Matrices
    Khalid A. Al-Saad
    Mohammed A. Amr
    Abdulfattah I. Helal
    Biological Trace Element Research, 2011, 140 : 103 - 113
  • [23] Determination of Nickel and Iron Carbonyl in Carbon Monoxide by ICP-MS Methods and a Pyrex Gas Washing System
    Zhou, Ze-Yi
    Xie, Li
    Bi, Zhe
    PROCEEDINGS OF THE 2ND ANNUAL INTERNATIONAL CONFERENCE ON ADVANCED MATERIAL ENGINEERING (AME 2016), 2016, 85 : 1341 - 1348
  • [24] Determination of selenium in milk powder by octopole reaction cell ICP-MS
    Cho, Sung-Eel
    Kim, Mi-Ju
    Kim, Yong-Ha
    Min, Young-Keun
    Kim, Young-Sang
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2006, 19 (03): : 203 - 210
  • [25] Accurate, Low-Level Sulfur Analysis by ICP-MS Using MS/MS with Oxygen Reaction Cell Gas
    McCurdy, Ed
    Woods, Glenn
    Georg, Bastian
    Sugiyama, Naoki
    SPECTROSCOPY, 2020, 35 : 27 - 34
  • [26] Fractionation and speciation of nickel and vanadium in crude oils by size exclusion chromatography-ICP MS and normal phase HPLC-ICP MS
    Caumette, Guilhem
    Lienemann, Charles-Philippe
    Merdrignac, Isabelle
    Bouyssiere, Brice
    Lobinski, Ryszard
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (07) : 1123 - 1129
  • [27] Interference removal in mass spectrometry for the determination of trace gold,mercury and selenium in nickel-based superalloys by ICP-MS/MS
    Wang, Zhaoying
    Chen, Xiongfei
    Xu, Yan
    Mo, Shumin
    Zhang, Fang
    Tong, Jian
    Liu, Ying
    Chinese Journal of Analysis Laboratory, 2024, 43 (08) : 1183 - 1189
  • [28] Multielemental determination in oil matrices diluted in xylene by ICP-MS with a dynamic reaction cell employing methane as reaction gas for solving specific interferences
    de Souza, Jefferson R.
    Duyck, Christiane B.
    Fonseca, Teresa C. O.
    Saint'Pierre, Tatiana D.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (08) : 1280 - 1286
  • [29] The ICP-MS determination of rare earths and other metals in Baikal crude oil: Comparison with crude oils in Siberia and the Russian Far East
    Yasnygina, T. A.
    Malykh, Yu. M.
    Rasskazov, S. V.
    Primina, S. P.
    Zemskaya, T. I.
    Khlystov, O. M.
    DOKLADY EARTH SCIENCES, 2006, 411 (08) : 1237 - 1240
  • [30] The ICP-MS determination of rare earths and other metals in Baikal crude oil: Comparison with crude oils in Siberia and the Russian Far East
    T. A. Yasnygina
    Yu. M. Malykh
    S. V. Rasskazov
    S. P. Primina
    T. I. Zemskaya
    O. M. Khlystov
    Doklady Earth Sciences, 2006, 411 : 1237 - 1240