Diurnal performance investigation of solar integrated ejector-based Combined Cooling, Heating, and Power (CCHP) system for Indian climate

被引:0
|
作者
Saladi, Joshua Kumar [1 ]
Suresh, Ronanki [1 ]
Datta, Santanu Prasad [1 ]
机构
[1] Birla Inst Technol & Sci BITS Pilani, Dept Mech Engn, Hyderabad Campus, Pilani 500078, India
关键词
Trigeneration; Parabolic trough collector; Organic Rankine cycle; Ejector; low-GWP refrigerant; ORGANIC RANKINE-CYCLE; THERMAL-ENERGY STORAGE; TRIGENERATION SYSTEM; OPTIMIZATION; COLLECTOR; DESIGN; DRIVEN;
D O I
10.1016/j.applthermaleng.2024.125250
中图分类号
O414.1 [热力学];
学科分类号
摘要
The increasing global energy demand, driven by population growth and geographical challenges to deliver grid power, necessitates a shift from traditional energy systems to renewable energy-based poly-generation systems to reduce fossil fuel consumption. Among many, a solar-integrated trigeneration system is the most emerging technology to provide combined cooling, heating, and power (CCHP) to address environmental concerns and enhance solar energy utilization. Therefore, a novel solar integrated ejector-based organic Rankine cycle (SEORC) is proposed for CCHP application and corresponding year-round dynamic analysis with the change of solar irradiation is conducted across five distinct climatic zones of India like arid, semi-arid, tropical wet and dry, tropical wet, and hilly regions. In the SEORC, the primary refrigerant flow is extracted in the first stage of ORC turbine expansion to explore the system's performance at sub-zero evaporator temperatures. The results show that the system's performance varies seasonally, with summer yielding optimal results. The semi-arid climate demonstrates the highest overall system efficiency of 28.04 %. In contrast, the tropical wet climate achieves the highest solar fraction of 1.89, power output of 21.55 kW, and heating capacity of 25.93 kW with a heat input of 158 kW, and 19.44 kW highest cooling capacity in the hilly environment. The results demonstrate that the SEORC system effectively delivers cooling for possible building thermal management. Notably, a tropical wet climate achieves the highest efficiency of 19.52 % and a solar fraction of 45 %. PTC and boiler are the primary sources of exergy destruction, contributing 60.05 % and 12.46 %.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] Energetic, Economic and Environmental Performance Analysis of a Micro-Combined Cooling, Heating and Power (CCHP) System Based on Biomass Gasification
    Perrone, Diego
    Castiglione, Teresa
    Morrone, Pietropaolo
    Pantano, Ferdinando
    Bova, Sergio
    ENERGIES, 2023, 16 (19)
  • [22] Combined Cooling Heating and Power System Integrated a Solar Thermochemical Process With Chemical Recuperation
    Liu, Tai-Xiu
    Sui, Jun
    Liu, Qi-Bin
    Liu, Feng
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2017, 38 (09): : 1815 - 1821
  • [23] Optimization of biomass gasification combined cooling, heating and power system integrated with solar energy
    Jie, Pengfei
    Li, Zhe
    Hu, Yang
    Liu, Chunhua
    Ren, Yanli
    JOURNAL OF BUILDING ENGINEERING, 2023, 70
  • [24] Multi-objective optimization of combined cooling, heating, and power (CCHP) system based on CNG engine
    Sheykhi, Mohammad
    Mehregan, Mahmood
    Emamian, Amin
    Ghorbani, Saeed
    Aliakbari, Karim
    Delouei, Amin Amiri
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 61
  • [25] Performance analysis and economic assessment of a combined cooling heating and power (CCHP) system in wastewater treatment plants (WWTPs)
    Farahbakhsh, Milad Tamjidi
    Chahartaghi, Mahmood
    ENERGY CONVERSION AND MANAGEMENT, 2020, 224
  • [26] Fluid selection optimization of a combined cooling, heating and power (CCHP) system for residential applications
    Javan, Saeed
    Mohamadi, Vahid
    Ahmadi, Pouria
    Hanafizadeh, Pedram
    APPLIED THERMAL ENGINEERING, 2016, 96 : 26 - 38
  • [27] Reliability and cost analysis of the redundant design of a combined cooling, heating and power (CCHP) system
    Jiang, Jinming
    Gao, Weijun
    Wei, Xindong
    Li, Yanxue
    Kuroki, Soichiro
    ENERGY CONVERSION AND MANAGEMENT, 2019, 199
  • [28] Solar-powered ejector-based adsorption desalination system integrated with a humidification-dehumidification system
    Ali, Ehab S.
    Mohammed, Ramy H.
    Qasem, Naef A. A.
    Zubair, Syed M.
    Askalany, Ahmed
    ENERGY CONVERSION AND MANAGEMENT, 2021, 238
  • [29] Exergoeconomic Optimization of an Integrated Supercritical CO2 Power Plant and Ejector-Based Refrigeration System for Electricity and Cooling Production
    Ramy H. Mohammed
    Naef A. A. Qasem
    Syed M. Zubair
    Arabian Journal for Science and Engineering, 2022, 47 : 9137 - 9149
  • [30] A dimensionless capacity design method for combined cooling, heating, and power (CCHP) systems based on energy matching performance
    Fu, Zhihao
    Feng, Lejun
    Sui, Jun
    Chu, Jiayu
    Dong, Rui
    ENERGY AND BUILDINGS, 2024, 313