A Geant4 Monte Carlo toolkit-based radiative transfer model for studying the impact of aerosols

被引:0
|
作者
Boudjella, M. Y. [1 ]
Belbachir, A. H. [1 ]
Dib, A. S. A. [1 ]
Meftah, M. [2 ]
机构
[1] Univ Sci & Technol Oran Mohamed Boudiaf USTO MB, Fac Phys, Lab Anal & Applicat Radiat LAAR, BP 1505, Oran 31000, Algeria
[2] Univ Paris Saclay, Sorbonne Univ, Univ Versailles St Quentin En Yvelines, Lab Atmospheres Milieux Observat Spatiales LATMOS,, 11 Blvd Alembert, F-78280 Guyancourt, France
关键词
Geant4; DISORT code; Global irradiance; Diffuse irradiance; TOA reflected irradiance; Radiative forcing; SKY SOLAR IRRADIANCE; PHOTOSYNTHETICALLY ACTIVE RADIATION; LIBRADTRAN SOFTWARE PACKAGE; MULTIPLE-SCATTERING; PART I; ATMOSPHERE; CODE; PERFORMANCE; VALIDATION; VERSION;
D O I
10.1016/j.asr.2024.07.057
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Radiative transfer models are of prime importance in quantifying the earth-atmosphere energy budget. A radiative transfer model based on the Geant4 Monte Carlo toolkit was developed. This model is able to perform calculations of the spectral atmospheric transmittance, surface solar irradiance, as well as the Top of the Atmosphere (TOA) reflected irradiance over the spectral range from 280 nm to 3000 nm. Through this study, the Geant4 toolkit was used to study the effect of rural aerosols concentration on different radiative characteristics. Geant4 radiative calculations in the presence and absence of aerosols were compared to that of DISORT code. For both surface and Top of the atmosphere simulations, good agreement was observed between the two models. Specifically, under atmospheric visibility conditions of 23 km, the mean relative difference between Geant4 and DISORT code was found to be less than 2.46 % for Global irradiance calculations and less than 7.9 % for TOA reflected irradiance. A comparative analysis between the measured total global irradiance in Adrar city and the irradiance estimated by Geant4 demonstrated the general effectiveness of Geant4, with a coefficient of determination of 0.991 and a Mean Absolute Percentage Error (MAPE) of 5.851 %.<br /> (c) 2024 COSPAR. Published by Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:74 / 90
页数:17
相关论文
共 50 条
  • [21] A framework for Monte Carlo simulation calculations in GEANT4
    Walker, B.
    Figgins, J.
    Comfort, J. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 889 - 895
  • [22] Geant4 Monte Carlo simulations for the LPCTrap setup
    D. Rodríguez
    G. Ban
    D. Durand
    F. Duval
    X. Fléchard
    E. Liénard
    F. Mauger
    A. Méry
    O. Naviliat-Cuncic
    J. -C. Thomas
    Ph. Velten
    The European Physical Journal A, 2009, 42 : 397 - 400
  • [23] Monte Carlo simulations in proton dosimetry with Geant4
    Moravek, Z
    Bogner, L
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S62 - S62
  • [24] A GATE/Geant4 Monte Carlo toolkit for surface dose calculation in VMAT breast cancer radiotherapy
    Arbor, Nicolas
    Gasteuil, Jean
    Noblet, Caroline
    Moreau, Matthieu
    Meyer, Philippe
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 61 : 112 - 117
  • [25] On the ionizing radiation protection properties of different chromium-based alloys: A study with the Geant4 Monte Carlo toolkit
    Hamad, Morad Kh.
    ANNALS OF NUCLEAR ENERGY, 2025, 213
  • [26] Studying the response of a plastic scintillator to gamma rays using the Geant4 Monte Carlo code
    Ghadiri, Rasoul
    Khorsandi, Jamshid
    APPLIED RADIATION AND ISOTOPES, 2015, 99 : 63 - 68
  • [27] Combination of electromagnetic physics processes for microdosimetry in liquid water with the Geant4 Monte Carlo simulation toolkit
    Ivanchenko, V. N.
    Incerti, S.
    Francis, Z.
    Tran, H. N.
    Karamitros, M.
    Bernal, M. A.
    Champion, C.
    Gueye, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2012, 273 : 95 - 97
  • [28] A comparison of cellular irradiation techniques with alpha particles using the Geant4 Monte Carlo simulation toolkit
    Incerti, S.
    Gault, N.
    Habchi, C.
    Lefaix, J. L.
    Moretto, Ph.
    Poncy, J. L.
    Pouthier, T.
    Seznec, H.
    RADIATION PROTECTION DOSIMETRY, 2006, 122 (1-4) : 327 - 329
  • [29] Geant4 Based Monte Carlo Dose Calculation Engine for Radiation Therapy
    Xiao, Shanjie
    Yang, Xue
    Sztejnberg, Manuel
    Jevremovic, Tatjana
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (02) : 775 - 781
  • [30] A CUDA Monte Carlo simulator for radiation therapy dosimetry based on Geant4
    Henderson, N.
    Murakami, K.
    Amako, K.
    Asai, M.
    Aso, T.
    Dotti, A.
    Kimura, A.
    Gerritsen, M.
    Kurashige, H.
    Perl, J.
    Sasaki, T.
    SNA + MC 2013 - JOINT INTERNATIONAL CONFERENCE ON SUPERCOMPUTING IN NUCLEAR APPLICATIONS + MONTE CARLO, 2014,