A Geant4 Monte Carlo toolkit-based radiative transfer model for studying the impact of aerosols

被引:0
|
作者
Boudjella, M. Y. [1 ]
Belbachir, A. H. [1 ]
Dib, A. S. A. [1 ]
Meftah, M. [2 ]
机构
[1] Univ Sci & Technol Oran Mohamed Boudiaf USTO MB, Fac Phys, Lab Anal & Applicat Radiat LAAR, BP 1505, Oran 31000, Algeria
[2] Univ Paris Saclay, Sorbonne Univ, Univ Versailles St Quentin En Yvelines, Lab Atmospheres Milieux Observat Spatiales LATMOS,, 11 Blvd Alembert, F-78280 Guyancourt, France
关键词
Geant4; DISORT code; Global irradiance; Diffuse irradiance; TOA reflected irradiance; Radiative forcing; SKY SOLAR IRRADIANCE; PHOTOSYNTHETICALLY ACTIVE RADIATION; LIBRADTRAN SOFTWARE PACKAGE; MULTIPLE-SCATTERING; PART I; ATMOSPHERE; CODE; PERFORMANCE; VALIDATION; VERSION;
D O I
10.1016/j.asr.2024.07.057
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Radiative transfer models are of prime importance in quantifying the earth-atmosphere energy budget. A radiative transfer model based on the Geant4 Monte Carlo toolkit was developed. This model is able to perform calculations of the spectral atmospheric transmittance, surface solar irradiance, as well as the Top of the Atmosphere (TOA) reflected irradiance over the spectral range from 280 nm to 3000 nm. Through this study, the Geant4 toolkit was used to study the effect of rural aerosols concentration on different radiative characteristics. Geant4 radiative calculations in the presence and absence of aerosols were compared to that of DISORT code. For both surface and Top of the atmosphere simulations, good agreement was observed between the two models. Specifically, under atmospheric visibility conditions of 23 km, the mean relative difference between Geant4 and DISORT code was found to be less than 2.46 % for Global irradiance calculations and less than 7.9 % for TOA reflected irradiance. A comparative analysis between the measured total global irradiance in Adrar city and the irradiance estimated by Geant4 demonstrated the general effectiveness of Geant4, with a coefficient of determination of 0.991 and a Mean Absolute Percentage Error (MAPE) of 5.851 %.<br /> (c) 2024 COSPAR. Published by Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:74 / 90
页数:17
相关论文
共 50 条
  • [1] Polarized electron Mott scattering model for the Geant4 Monte Carlo toolkit
    Dragowski, M.
    Adamus, M.
    Weber, G.
    Wlodarczyk, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2021, 488 : 37 - 42
  • [2] Cellular Dosimetry Using the Geant4 Monte Carlo Toolkit
    Freudenberg, Robert
    Kotzerke, Jorg
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) : 1488 - 1489
  • [3] Dosimetric Validation of An Intrabeam™ GATE Model, Based On Monte Carlo GEANT4 Toolkit, for IORT Applications
    Bouzid, D.
    Visvikis, D.
    Dupre, P.
    Bert, J.
    Pradier, O.
    Nicolas, B.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [4] Cellular Dosimetry Using the Geant4 Monte Carlo Toolkit REPLY
    Cai, Zhongli
    Pignol, Jean-Philippe
    Chan, Conrad
    Reilly, Raymond M.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) : 1489 - 1489
  • [5] Monte Carlo simulation of the CENBG microbeam and nanobeam lines with the Geant4 toolkit
    Incerti, S.
    Zhang, Q.
    Andersson, F.
    Moretto, Ph.
    Grime, G. W.
    Merchant, M. J.
    Nguyen, D. T.
    Habchi, C.
    Pouthier, T.
    Seznec, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 260 (01): : 20 - 27
  • [6] The Geant4 Virtual Monte Carlo
    Hrivnacova, I.
    INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS 2012 (CHEP2012), PTS 1-6, 2012, 396
  • [7] Applications of the Monte Carlo method in nuclear physics using the GEANT4 toolkit
    Moralles, Mauricio
    Guimaraes, Carla C.
    Bonifacio, Daniel A. B.
    Okuno, Emico
    Murata, Helio M.
    Bottaro, Marcio
    Menezes, Mario O.
    Guimaraes, Valdir
    NUCLEAR PHYSICS 2008: XXXI WORKSHOP ON NUCLEAR PHYSICS IN BRAZIL, 2009, 1139 : 51 - +
  • [8] Calculation of surface spectral irradiance using the Geant4 Monte Carlo toolkit
    Boudjella, Manal Yasmine
    Belbachir, Ahmed Hafid
    Dib, Samy Anis Amine
    Meftah, Mustapha
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2023, 248
  • [9] Validation of Independent IMRT and VMAT Dose Calculation System based on Geant4 Monte Carlo Toolkit
    Choi, H. J.
    Park, H.
    Shin, W. G.
    Kim, J. I.
    Min, C. H.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S942 - S942
  • [10] Verification and Validation of the Geant4 Monte Carlo Code Toolkit for DEMO TBR Evaluations
    Nunnenmann, Elena
    Fischer, Ulrich
    Serikov, Arkady
    FUSION ENGINEERING AND DESIGN, 2020, 161